Literature DB >> 25683219

Reliability of panoramic ultrasound imaging in simultaneously examining muscle size and quality of the hamstring muscles in young, healthy males and females.

Ty B Palmer1, Kazuma Akehi2, Ryan M Thiele1, Doug B Smith1, Brennan J Thompson3.   

Abstract

The purpose of this study was to examine the reliability of ultrasound (US) measures of cross-sectional area (CSA), muscle thickness (MT) and echo intensity (EI) of the hamstrings, with comparisons between males and females. In 20 healthy participants (10 males, 10 females), CSA, MT and EI were measured from panoramic US scans of the hamstrings on 2 separate days. The intra-class correlation coefficients and standard errors of measurement as a percentage of the mean for CSA, MT and EI ranged from 0.715 to 0.984 and from 3.145 to 12.541% in the males and from 0.724 to 0.977 and from 4.571 to 17.890% in the females, respectively. The males had greater CSAs and MTs and lower EIs than the females (p = 0.002-0.049), and significant relationships were observed between CSA and MT (r = 0.714-0.938, p ≤ 0.001-0.023). From an overall reliability standpoint, these findings suggest that panoramic US may be a reliable technique for examining muscle size and quality of the hamstrings in both males and females.
Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Biceps femoris; Cross-sectional area; Echo intensity; Gender; Muscle thickness; Semimembranosus; Semitendinosus

Mesh:

Year:  2015        PMID: 25683219     DOI: 10.1016/j.ultrasmedbio.2014.10.011

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  11 in total

1.  Changes in the sensorimotor system and semitendinosus muscle morphometry after arthroscopic anterior cruciate ligament reconstruction: a prospective cohort study with 1-year follow-up.

Authors:  Marialuisa Gandolfi; Matteo Ricci; Elena Sambugaro; Nicola Valè; Eleonora Dimitrova; Andrea Meschieri; Silvano Grazioli; Alessandro Picelli; Calogero Foti; Francesco Rulli; Nicola Smania
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-06-21       Impact factor: 4.342

Review 2.  Echo intensity as an indicator of skeletal muscle quality: applications, methodology, and future directions.

Authors:  Matt S Stock; Brennan J Thompson
Journal:  Eur J Appl Physiol       Date:  2020-11-21       Impact factor: 3.078

3.  Reliability of size and echo intensity of abdominal skeletal muscles using extended field-of-view ultrasound imaging.

Authors:  Noriko I Tanaka; Madoka Ogawa; Akito Yoshiko; Ryosuke Ando; Hiroshi Akima
Journal:  Eur J Appl Physiol       Date:  2017-09-14       Impact factor: 3.078

4.  Echo intensity reliability between two rectus femoris probe sites.

Authors:  Rodrigo Rabello; Matias Fröhlich; Aline Felicio Bueno; Miriam Allein Zago Marcolino; Thainá De Bona Bernardi; Graciele Sbruzzi; Marco Aurélio Vaz
Journal:  Ultrasound       Date:  2019-06-06

5.  Sonographic measures and sensory threshold of the normal sciatic nerve and hamstring muscles.

Authors:  Stacey M Cornelson; Ashley N Ruff; Courtney Wells; Roberta Sclocco; Norman W Kettner
Journal:  J Ultrasound       Date:  2021-01-30

6.  Acute Effects of Open Kinetic Chain Exercise Versus Those of Closed Kinetic Chain Exercise on Quadriceps Muscle Thickness in Healthy Adults.

Authors:  Soul Cheon; Joo-Hyun Lee; Hyung-Pil Jun; Yong Woo An; Eunwook Chang
Journal:  Int J Environ Res Public Health       Date:  2020-06-29       Impact factor: 3.390

Review 7.  Sonographic landmarks in hamstring muscles.

Authors:  Ramon Balius; Carles Pedret; Iñigo Iriarte; Rubén Sáiz; Luis Cerezal
Journal:  Skeletal Radiol       Date:  2019-04-17       Impact factor: 2.199

8.  Age- and muscle-specific reliability of muscle architecture measurements assessed by two-dimensional panoramic ultrasound.

Authors:  Iris Hagoort; Tibor Hortobágyi; Nicolas Vuillerme; Claudine J C Lamoth; Alessio Murgia
Journal:  Biomed Eng Online       Date:  2022-02-13       Impact factor: 2.819

9.  Ultrasound imaging in women's arm flexor muscles: intra-rater reliability of muscle thickness and echo intensity.

Authors:  Amilton Vieira; Angelina F Siqueira; João B Ferreira-Junior; Paulo Pereira; Dale Wagner; Martim Bottaro
Journal:  Braz J Phys Ther       Date:  2016-09-15       Impact factor: 3.377

10.  Evaluation of the Lower Trapezius Muscle Using Ultrasound Panoramic View (a Novel Approach): An Intra- and Inter-Rater Reliability Study.

Authors:  Samuel Fernández-Carnero; Alejandro Garrido-Marín; Alexander Achalandabaso-Ochoa; Alejandro Ferragut-Garcías; Rubén Fernández-Matías; Daniel Pecos-Martín; Tomás Gallego-Izquierdo
Journal:  Int J Environ Res Public Health       Date:  2020-09-29       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.