Reliability of size and echo intensity of abdominal skeletal muscles using extended field-of-view ultrasound imaging.

Noriko I Tanaka1,2, Madoka Ogawa3,4, Akito Yoshiko5, Ryosuke Ando6, Hiroshi Akima7,3.   

Abstract

PURPOSE: This study aimed to examine the reliability of extended field-of-view (EFOV) ultrasound imaging to evaluate the cross-sectional area (CSA) and echo intensity of abdominal skeletal muscles.
METHODS: Twenty-seven healthy young males (age 18.6 ± 1.0 years, body mass index 20.9 ± 2.8 kg/m2, waist circumference 75.0 ± 7.9 cm, body fat 16.6 ± 5.9%) visited the laboratory on 2 days. EFOV ultrasound images of the rectus abdominis, abdominal oblique, and erector spinae muscles were acquired at the height of the third lumbar vertebra with the subject lying on a bed. We then analyzed CSA and echo intensity using ImageJ software and calculated intra-class correlation coefficients (ICC) and the standard error of measurement (SEM).
RESULTS: No significant differences (p = 0.149-0.679) were observed in CSA or echo intensity values for each skeletal muscle between days. ICC and SEM values in CSA for each skeletal muscle ranged between 0.944 and 0.958 and 4.9% and 7.3%, respectively. The corresponding values for echo intensity were 0.851-0.945 for ICC and 5.3-9.7% for SEM.
CONCLUSIONS: The present results indicate that EFOV ultrasound imaging has high repeatability for measuring CSA and echo intensity of abdominal skeletal muscle groups in healthy college-aged males.

Entities:  

Keywords:  Cross-sectional area; Muscle quality; Panoramic image; Trunk skeletal muscle

Mesh:

Year:  2017        PMID: 28913554     DOI: 10.1007/s00421-017-3713-y

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  24 in total

1.  Applicability of a segmental bioelectrical impedance analysis for predicting the whole body skeletal muscle volume.

Authors:  Noriko I Tanaka; Masae Miyatani; Yoshihisa Masuo; Tetsuo Fukunaga; Hiroaki Kanehisa
Journal:  J Appl Physiol (1985)       Date:  2007-08-30

2.  Skeletal muscle ultrasound: correlation between fibrous tissue and echo intensity.

Authors:  Sigrid Pillen; Ramon O Tak; Machiel J Zwarts; Martin M Y Lammens; Kiek N Verrijp; Ilse M P Arts; Jeroen A van der Laak; Peter M Hoogerbrugge; Baziel G M van Engelen; Aad Verrips
Journal:  Ultrasound Med Biol       Date:  2008-12-10       Impact factor: 2.998

3.  Reliability of panoramic ultrasound imaging in simultaneously examining muscle size and quality of the hamstring muscles in young, healthy males and females.

Authors:  Ty B Palmer; Kazuma Akehi; Ryan M Thiele; Doug B Smith; Brennan J Thompson
Journal:  Ultrasound Med Biol       Date:  2015-03       Impact factor: 2.998

4.  Distribution of subcutaneous fat and muscle thicknesses in young and middle-aged women.

Authors:  Y Ishida; H Kanehisa; J F Carroll; M L Pollock; J E Graves; L Ganzarella
Journal:  Am J Hum Biol       Date:  1997       Impact factor: 1.937

5.  Association of visceral fat area with abdominal skeletal muscle distribution in overweight Japanese adults.

Authors:  Noriko I Tanaka; Haruka Murakami; Yumi Ohmori; Naomi Aiba; Akemi Morita; Shaw Watanabe; Motohiko Miyachi
Journal:  Obes Res Clin Pract       Date:  2016-07-21       Impact factor: 2.288

6.  Prediction equations for body composition of Japanese adults by B-mode ultrasound.

Authors:  Takashi Abe; Masakatsu Kondo; Yasuo Kawakami; Tetsuo Fukunaga
Journal:  Am J Hum Biol       Date:  1994       Impact factor: 1.937

7.  Assessment of quadriceps muscle cross-sectional area by ultrasound extended-field-of-view imaging.

Authors:  M Noorkoiv; K Nosaka; A J Blazevich
Journal:  Eur J Appl Physiol       Date:  2010-02-27       Impact factor: 3.078

8.  Sarcopenia: European consensus on definition and diagnosis: Report of the European Working Group on Sarcopenia in Older People.

Authors:  Alfonso J Cruz-Jentoft; Jean Pierre Baeyens; Jürgen M Bauer; Yves Boirie; Tommy Cederholm; Francesco Landi; Finbarr C Martin; Jean-Pierre Michel; Yves Rolland; Stéphane M Schneider; Eva Topinková; Maurits Vandewoude; Mauro Zamboni
Journal:  Age Ageing       Date:  2010-04-13       Impact factor: 10.668

9.  Intramuscular adipose tissue determined by T1-weighted MRI at 3T primarily reflects extramyocellular lipids.

Authors:  Hiroshi Akima; Maya Hioki; Akito Yoshiko; Teruhiko Koike; Hisataka Sakakibara; Hideyuki Takahashi; Yoshiharu Oshida
Journal:  Magn Reson Imaging       Date:  2015-12-30       Impact factor: 2.546

10.  Evaluation of muscle quality reliability and racial differences in body composition of overweight individuals.

Authors:  Malia N Melvin; Abbie E Smith-Ryan; Hailee L Wingfield; Sarah N Fultz; Erica J Roelofs
Journal:  Ultrasound Med Biol       Date:  2014-06-07       Impact factor: 2.998

View more
  6 in total

1.  Differences in muscle thickness and echo intensity between stroke survivors and age- and sex-matched healthy older adults.

Authors:  Hiroki Monjo; Yoshihiro Fukumoto; Tsuyoshi Asai; Hiroki Kubo; Kensuke Ohshima; Hirotsugu Tajitsu; Shota Koyama
Journal:  Phys Ther Res       Date:  2020-08-20

Review 2.  Echo intensity as an indicator of skeletal muscle quality: applications, methodology, and future directions.

Authors:  Matt S Stock; Brennan J Thompson
Journal:  Eur J Appl Physiol       Date:  2020-11-21       Impact factor: 3.078

3.  Internal and External Oblique Muscle Asymmetry in Sprint Hurdlers and Sprinters: A Cross-Sectional Study.

Authors:  Lauren Adams; Nicolas Pace; Austin Heo; Iain Hunter; A Wayne Johnson; Ulrike H Mitchell
Journal:  J Sports Sci Med       Date:  2022-02-15       Impact factor: 2.988

4.  Echo intensity reliability between two rectus femoris probe sites.

Authors:  Rodrigo Rabello; Matias Fröhlich; Aline Felicio Bueno; Miriam Allein Zago Marcolino; Thainá De Bona Bernardi; Graciele Sbruzzi; Marco Aurélio Vaz
Journal:  Ultrasound       Date:  2019-06-06

5.  Extended field-of-view ultrasound imaging is reliable for measuring Transversus Abdominis muscle size at rest and during contraction.

Authors:  A Wayne Johnson; Lauren Adams; Jade B Kho; Daniel M Green; Nicolas B Pace; Ulrike H Mitchell
Journal:  BMC Musculoskelet Disord       Date:  2021-03-17       Impact factor: 2.362

6.  A clinically applicable tool for rapidly estimating muscle volume using ultrasound images.

Authors:  Daniel T Rothwell; Daniel T P Fong; Sarah A Stapley; David J Williams
Journal:  Eur J Appl Physiol       Date:  2019-10-25       Impact factor: 3.078

  6 in total