Literature DB >> 25674998

Iterative CBCT reconstruction using Hessian penalty.

Tao Sun1, Nanbo Sun, Jing Wang, Shan Tan.   

Abstract

Statistical iterative reconstruction algorithms have shown potential to improve cone-beam CT (CBCT) image quality. Most iterative reconstruction algorithms utilize prior knowledge as a penalty term in the objective function. The penalty term greatly affects the performance of a reconstruction algorithm. The total variation (TV) penalty has demonstrated great ability in suppressing noise and improving image quality. However, calculated from the first-order derivatives, the TV penalty leads to the well-known staircase effect, which sometimes makes the reconstructed images oversharpen and unnatural. In this study, we proposed to use a second-order derivative penalty that involves the Frobenius norm of the Hessian matrix of an image for CBCT reconstruction. The second-order penalty retains some of the most favorable properties of the TV penalty like convexity, homogeneity, and rotation and translation invariance, and has a better ability in preserving the structures of gradual transition in the reconstructed images. An effective algorithm was developed to minimize the objective function with the majorization-minimization (MM) approach. The experiments on a digital phantom and two physical phantoms demonstrated the priority of the proposed penalty, particularly in suppressing the staircase effect of the TV penalty.

Mesh:

Year:  2015        PMID: 25674998     DOI: 10.1088/0031-9155/60/5/1965

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

1.  Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging.

Authors:  Steven Tilley; Matthew Jacobson; Qian Cao; Michael Brehler; Alejandro Sisniega; Wojciech Zbijewski; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

2.  Structure-adaptive CBCT reconstruction using weighted total variation and Hessian penalties.

Authors:  Qi Shi; Nanbo Sun; Tao Sun; Jing Wang; Shan Tan
Journal:  Biomed Opt Express       Date:  2016-08-09       Impact factor: 3.732

Review 3.  Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

Authors:  Hao Zhang; Jing Wang; Dong Zeng; Xi Tao; Jianhua Ma
Journal:  Med Phys       Date:  2018-09-10       Impact factor: 4.071

4.  Fast, long-term, super-resolution imaging with Hessian structured illumination microscopy.

Authors:  Xiaoshuai Huang; Junchao Fan; Liuju Li; Haosen Liu; Runlong Wu; Yi Wu; Lisi Wei; Heng Mao; Amit Lal; Peng Xi; Liqiang Tang; Yunfeng Zhang; Yanmei Liu; Shan Tan; Liangyi Chen
Journal:  Nat Biotechnol       Date:  2018-04-11       Impact factor: 54.908

5.  Statistical Iterative CBCT Reconstruction Based on Neural Network.

Authors:  Binbin Chen; Kai Xiang; Zaiwen Gong; Jing Wang; Shan Tan
Journal:  IEEE Trans Med Imaging       Date:  2018-06       Impact factor: 10.048

6.  A moving blocker-based strategy for simultaneous megavoltage and kilovoltage scatter correction in cone-beam computed tomography image acquired during volumetric modulated arc therapy.

Authors:  Luo Ouyang; Huichen Pam Lee; Jing Wang
Journal:  Radiother Oncol       Date:  2015-05-27       Impact factor: 6.280

7.  Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image.

Authors:  Xiao Jia; Yuting Liao; Dong Zeng; Hao Zhang; Yuanke Zhang; Ji He; Zhaoying Bian; Yongbo Wang; Xi Tao; Zhengrong Liang; Jing Huang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2018-11-20       Impact factor: 3.609

8.  Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Phys Med Biol       Date:  2015-12-09       Impact factor: 3.609

9.  Robust Low-Dose CT Sinogram Preprocessing via Exploiting Noise-Generating Mechanism.

Authors:  Qi Xie; Dong Zeng; Qian Zhao; Deyu Meng; Zongben Xu; Zhengrong Liang; Jianhua Ma
Journal:  IEEE Trans Med Imaging       Date:  2017-12       Impact factor: 10.048

10.  Low-Dose CBCT Reconstruction Using Hessian Schatten Penalties.

Authors:  Liang Liu; Xinxin Li; Kai Xiang; Jing Wang; Shan Tan
Journal:  IEEE Trans Med Imaging       Date:  2017-12       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.