Sowmya Srinivas1, Ou Tan2, Shuang Wu3, Muneeswar Gupta Nittala1, David Huang2, Rohit Varma3, SriniVas R Sadda4. 1. Doppler OCT Reading Center, Doheny Eye Institute, Los Angeles, California, United States. 2. Casey Eye Institute, Oregon Health & Science University, Portland, Oregon, United States. 3. Department of Ophthalmology, Keck School of Medicine, University of Southern California, Los Angeles, California, United States. 4. Doppler OCT Reading Center, Doheny Eye Institute, Los Angeles, California, United States Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, California, United States.
Abstract
PURPOSE: To measure total retinal blood flow (TRBF) in normal, healthy Chinese Americans by using semi-automated analysis of Doppler Fourier-domain optical coherence tomography (FD-OCT) scans. METHODS: Two hundred sixty-six normal, healthy Chinese-American participants (266 eyes) were enrolled from The Chinese American Eye Study. All participants underwent complete ophthalmic examination, including best-corrected visual acuity, indirect ophthalmoscopy, and Doppler FD-OCT imaging, using the circumpapillary double circular scan protocol. Total retinal blood flow and other vascular parameters (e.g., venous and arterial cross-sectional area and their velocities) were calculated by using Doppler OCT of Retinal Circulation software. Associations between TRBF and other clinical parameters were assessed by using bivariate correlations and linear regression. RESULTS: The mean age of study participants was 57.40 ± 5.60 (range, 50-82) years. The mean TRBF was 49.34 ± 10.08 (range, 27.17-78.08, 95% confidence interval: 25.98-69.10) μL/min. The mean venous area was 0.0548 (±0.0084) mm(2). Superior retinal hemispheric blood flow (25.50 ± 6.62 μL/min) was slightly greater than inferior retinal hemispheric blood flow (23.84 ± 7.19 μL/min, P = 0.008). The mean flow velocity was 15.16 ± 3.12 mm/s. There was a weak but significant negative correlation between TRBF and age (r = -0.15, P = 0.012). No significant correlation was found between TRBF and axial length (r = 0.11, P = 0.08). Retinal blood flow was not significantly correlated with any other clinical parameters, including body mass index, systolic blood pressure, diastolic blood pressure, and intraocular pressure. CONCLUSIONS: Normal Doppler OCT-derived total retinal blood values in a Chinese-American population showed considerable variability, some of which was explained by age. These observations should help design future studies evaluating TRBF in populations with eye disease. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.
PURPOSE: To measure total retinal blood flow (TRBF) in normal, healthy Chinese Americans by using semi-automated analysis of Doppler Fourier-domain optical coherence tomography (FD-OCT) scans. METHODS: Two hundred sixty-six normal, healthy Chinese-American participants (266 eyes) were enrolled from The Chinese American Eye Study. All participants underwent complete ophthalmic examination, including best-corrected visual acuity, indirect ophthalmoscopy, and Doppler FD-OCT imaging, using the circumpapillary double circular scan protocol. Total retinal blood flow and other vascular parameters (e.g., venous and arterial cross-sectional area and their velocities) were calculated by using Doppler OCT of Retinal Circulation software. Associations between TRBF and other clinical parameters were assessed by using bivariate correlations and linear regression. RESULTS: The mean age of study participants was 57.40 ± 5.60 (range, 50-82) years. The mean TRBF was 49.34 ± 10.08 (range, 27.17-78.08, 95% confidence interval: 25.98-69.10) μL/min. The mean venous area was 0.0548 (±0.0084) mm(2). Superior retinal hemispheric blood flow (25.50 ± 6.62 μL/min) was slightly greater than inferior retinal hemispheric blood flow (23.84 ± 7.19 μL/min, P = 0.008). The mean flow velocity was 15.16 ± 3.12 mm/s. There was a weak but significant negative correlation between TRBF and age (r = -0.15, P = 0.012). No significant correlation was found between TRBF and axial length (r = 0.11, P = 0.08). Retinal blood flow was not significantly correlated with any other clinical parameters, including body mass index, systolic blood pressure, diastolic blood pressure, and intraocular pressure. CONCLUSIONS: Normal Doppler OCT-derived total retinal blood values in a Chinese-American population showed considerable variability, some of which was explained by age. These observations should help design future studies evaluating TRBF in populations with eye disease. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.
Authors: Yimin Wang; Amani A Fawzi; Rohit Varma; Alfredo A Sadun; Xinbo Zhang; Ou Tan; Joseph A Izatt; David Huang Journal: Invest Ophthalmol Vis Sci Date: 2011-02-11 Impact factor: 4.799
Authors: Rupesh Agrawal; Praveen Kumar Balne; Sai Bo Bo Tun; Yeo Sia Wey; Neha Khandelwal; Veluchamy A Barathi Journal: J Vis Exp Date: 2017-07-03 Impact factor: 1.355
Authors: L-A Khuu; F Tayyari; J M Sivak; J G Flanagan; S Singer; M H Brent; D Huang; O Tan; C Hudson Journal: Eye (Lond) Date: 2017-05-26 Impact factor: 3.775
Authors: Lee-Anne Khuu; Faryan Tayyari; Jeremy M Sivak; John G Flanagan; Shaun Singer; Michael H Brent; David Huang; Ou Tan; Christopher Hudson Journal: Acta Ophthalmol Date: 2016-09-28 Impact factor: 3.761
Authors: Stephan Szegedi; Nikolaus Hommer; Martin Kallab; Stefan Puchner; Doreen Schmidl; René M Werkmeister; Gerhard Garhöfer; Leopold Schmetterer Journal: Transl Vis Sci Technol Date: 2020-06-25 Impact factor: 3.283
Authors: Anastasios G Konstas; Leopold Schmetterer; Andreas Katsanos; Cindy M L Hutnik; Gábor Holló; Luciano Quaranta; Miguel A Teus; Hannu Uusitalo; Norbert Pfeiffer; L Jay Katz Journal: Adv Ther Date: 2020-10-27 Impact factor: 3.845