Literature DB >> 25652522

A computational model to generate simulated three-dimensional breast masses.

Luis de Sisternes1, Jovan G Brankov1, Adam M Zysk1, Robert A Schmidt2, Robert M Nishikawa3, Miles N Wernick1.   

Abstract

PURPOSE: To develop algorithms for creating realistic three-dimensional (3D) simulated breast masses and embedding them within actual clinical mammograms. The proposed techniques yield high-resolution simulated breast masses having randomized shapes, with user-defined mass type, size, location, and shape characteristics.
METHODS: The authors describe a method of producing 3D digital simulations of breast masses and a technique for embedding these simulated masses within actual digitized mammograms. Simulated 3D breast masses were generated by using a modified stochastic Gaussian random sphere model to generate a central tumor mass, and an iterative fractal branching algorithm to add complex spicule structures. The simulated masses were embedded within actual digitized mammograms. The authors evaluated the realism of the resulting hybrid phantoms by generating corresponding left- and right-breast image pairs, consisting of one breast image containing a real mass, and the opposite breast image of the same patient containing a similar simulated mass. The authors then used computer-aided diagnosis (CAD) methods and expert radiologist readers to determine whether significant differences can be observed between the real and hybrid images.
RESULTS: The authors found no statistically significant difference between the CAD features obtained from the real and simulated images of masses with either spiculated or nonspiculated margins. Likewise, the authors found that expert human readers performed very poorly in discriminating their hybrid images from real mammograms.
CONCLUSIONS: The authors' proposed method permits the realistic simulation of 3D breast masses having user-defined characteristics, enabling the creation of a large set of hybrid breast images containing a well-characterized mass, embedded within real breast background. The computational nature of the model makes it suitable for detectability studies, evaluation of computer aided diagnosis algorithms, and teaching purposes.

Entities:  

Mesh:

Year:  2015        PMID: 25652522      PMCID: PMC4320152          DOI: 10.1118/1.4905232

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  25 in total

1.  Computerized classification of benign and malignant masses on digitized mammograms: a study of robustness.

Authors:  Z Huo; M L Giger; C J Vyborny; D E Wolverton; C E Metz
Journal:  Acad Radiol       Date:  2000-12       Impact factor: 3.173

2.  Multiple-image radiography.

Authors:  Miles N Wernick; Oliver Wirjadi; Dean Chapman; Zhong Zhong; Nikolas P Galatsanos; Yongyi Yang; Jovan G Brankov; Oral Oltulu; Mark A Anastasio; Carol Muehleman
Journal:  Phys Med Biol       Date:  2003-12-07       Impact factor: 3.609

3.  Power estimation for the Dorfman-Berbaum-Metz method.

Authors:  Stephen L Hillis; Kevin S Berbaum
Journal:  Acad Radiol       Date:  2004-11       Impact factor: 3.173

4.  The Physiological Principle of Minimum Work: I. The Vascular System and the Cost of Blood Volume.

Authors:  C D Murray
Journal:  Proc Natl Acad Sci U S A       Date:  1926-03       Impact factor: 11.205

5.  A comparison of denominator degrees of freedom methods for multiple observer ROC analysis.

Authors:  Stephen L Hillis
Journal:  Stat Med       Date:  2007-02-10       Impact factor: 2.373

6.  A computed tomography implementation of multiple-image radiography.

Authors:  Jovan G Brankov; Miles N Wernick; Yongyi Yang; Jun Li; Carol Muehleman; Zhong Zhong; Mark A Anastasio
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

7.  Recent developments in the Dorfman-Berbaum-Metz procedure for multireader ROC study analysis.

Authors:  Stephen L Hillis; Kevin S Berbaum; Charles E Metz
Journal:  Acad Radiol       Date:  2008-05       Impact factor: 3.173

8.  Automated computerized classification of malignant and benign masses on digitized mammograms.

Authors:  Z Huo; M L Giger; C J Vyborny; D E Wolverton; R A Schmidt; K Doi
Journal:  Acad Radiol       Date:  1998-03       Impact factor: 3.173

9.  An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV.

Authors:  J M Boone; J A Seibert
Journal:  Med Phys       Date:  1997-11       Impact factor: 4.071

10.  Branching characteristics of human coronary arteries.

Authors:  M Zamir; H Chee
Journal:  Can J Physiol Pharmacol       Date:  1986-06       Impact factor: 2.273

View more
  19 in total

1.  Population of 224 realistic human subject-based computational breast phantoms.

Authors:  David W Erickson; Jered R Wells; Gregory M Sturgeon; Ehsan Samei; James T Dobbins; W Paul Segars; Joseph Y Lo
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

2.  Validation of a Projection-domain Insertion of Liver Lesions into CT Images.

Authors:  Baiyu Chen; Chi Ma; Shuai Leng; Jeff L Fidler; Shannon P Sheedy; Cynthia H McCollough; Joel G Fletcher; Lifeng Yu
Journal:  Acad Radiol       Date:  2016-07-16       Impact factor: 3.173

3.  Evaluation of data augmentation via synthetic images for improved breast mass detection on mammograms using deep learning.

Authors:  Kenny H Cha; Nicholas Petrick; Aria Pezeshk; Christian G Graff; Diksha Sharma; Andreu Badal; Berkman Sahiner
Journal:  J Med Imaging (Bellingham)       Date:  2019-11-22

4.  Advances in Computational Human Phantoms and Their Applications in Biomedical Engineering - A Topical Review.

Authors:  Wolfgang Kainz; Esra Neufeld; Wesley E Bolch; Christian G Graff; Chan Hyeong Kim; Niels Kuster; Bryn Lloyd; Tina Morrison; Paul Segars; Yeon Soo Yeom; Maria Zankl; X George Xu; Benjamin M W Tsui
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-01

5.  Systematic analysis of bias and variability of morphologic features for lung lesions in computed tomography.

Authors:  Jocelyn Hoye; Justin Solomon; Thomas J Sauer; Marthony Robins; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2019-03-26

6.  Virtual assessment of stereoscopic viewing of digital breast tomosynthesis projection images.

Authors:  Gezheng Wen; Ho-Chang Chang; Jacob Reinhold; Joseph Y Lo; Mia K Markey
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-17

7.  Interchangeability between real and three-dimensional simulated lung tumors in computed tomography: an interalgorithm volumetry study.

Authors:  Marthony Robins; Justin Solomon; Jocelyn Hoye; Taylor Smith; Yuese Zheng; Lukas Ebner; Kingshuk Roy Choudhury; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2018-09-24

8.  Objective assessment of task performance: a comparison of two FFDM detectors using an anthropomorphic breast phantom.

Authors:  Andrey Makeev; Lynda C Ikejimba; Jesse Salad; Stephen J Glick
Journal:  J Med Imaging (Bellingham)       Date:  2019-10-17

9.  Virtual clinical trial for quantifying the effects of beam collimation and pitch on image quality in computed tomography.

Authors:  Ehsan Abadi; William P Segars; Brian Harrawood; Shobhit Sharma; Anuj Kapadia; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2020-06-01

10.  Lesion insertion in the projection domain: Methods and initial results.

Authors:  Baiyu Chen; Shuai Leng; Lifeng Yu; Zhicong Yu; Chi Ma; Cynthia McCollough
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.