Ehsan Abadi1, William P Segars1,2,3, Brian Harrawood1, Shobhit Sharma1,4, Anuj Kapadia1,2,4, Ehsan Samei1,2,3,4,5. 1. Duke University School of Medicine, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Durham, North Carolina, United States. 2. Duke University School of Medicine, Medical Physics Graduate Program, Durham, North Carolina, United States. 3. Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States. 4. Duke University, Department of Physics, Durham, North Carolina, United States. 5. Duke University, Department of Electrical and Computer Engineering, Durham, North Carolina, United States.
Abstract
Purpose: To utilize a virtual clinical trial (VCT) construct to investigate the effects of beam collimation and pitch on image quality (IQ) in computed tomography (CT) under different respiratory and cardiac motion rates. Approach: A computational human model [extended cardiac-torso (XCAT) phantom] with added lung lesions was used to simulate seven different rates of cardiac and respiratory motions. A validated CT simulator (DukeSim) was used in this study. A supplemental validation was done to ensure the accuracy of DukeSim across different pitches and beam collimations. Each XCAT phantom was imaged using the CT simulator at multiple pitches (0.5 to 1.5) and beam collimations (19.2 to 57.6 mm) at a constant dose level. The images were compared against the ground truth using three task-generic IQ metrics in the lungs. Additionally, the bias and variability in radiomics (morphological) feature measurements were quantified for task-specific lung lesion quantification across the studied imaging conditions. Results: All task-generic metrics degraded by 1.6% to 13.3% with increasing pitch. When imaged with motion, increasing pitch reduced motion artifacts. The IQ slightly degraded (1.3%) with changes in the studied beam collimations. Patient motion exhibited negative effects (within 7%) on the IQ. Among all features across all imaging conditions studies, compactness2 and elongation showed the largest ( - 26.5 % , 7.8%) and smallest ( - 0.8 % , 2.7%) relative bias and variability. The radiomics results were robust across the motion profiles studied. Conclusions: While high pitch and large beam collimations can negatively affect the quality of CT images, they are desirable for fast imaging. Further, our results showed no major adverse effects in morphology quantification of lung lesions with the increase in pitch or beam collimation. VCTs, such as the one demonstrated in this study, represent a viable methodology for experiments in CT.
Purpose: To utilize a virtual clinical trial (VCT) construct to investigate the effects of beam collimation and pitch on image quality (IQ) in computed tomography (CT) under different respiratory and cardiac motion rates. Approach: A computational human model [extended cardiac-torso (XCAT) phantom] with added lung lesions was used to simulate seven different rates of cardiac and respiratory motions. A validated CT simulator (DukeSim) was used in this study. A supplemental validation was done to ensure the accuracy of DukeSim across different pitches and beam collimations. Each XCAT phantom was imaged using the CT simulator at multiple pitches (0.5 to 1.5) and beam collimations (19.2 to 57.6 mm) at a constant dose level. The images were compared against the ground truth using three task-generic IQ metrics in the lungs. Additionally, the bias and variability in radiomics (morphological) feature measurements were quantified for task-specific lung lesion quantification across the studied imaging conditions. Results: All task-generic metrics degraded by 1.6% to 13.3% with increasing pitch. When imaged with motion, increasing pitch reduced motion artifacts. The IQ slightly degraded (1.3%) with changes in the studied beam collimations. Patient motion exhibited negative effects (within 7%) on the IQ. Among all features across all imaging conditions studies, compactness2 and elongation showed the largest ( - 26.5 % , 7.8%) and smallest ( - 0.8 % , 2.7%) relative bias and variability. The radiomics results were robust across the motion profiles studied. Conclusions: While high pitch and large beam collimations can negatively affect the quality of CT images, they are desirable for fast imaging. Further, our results showed no major adverse effects in morphology quantification of lung lesions with the increase in pitch or beam collimation. VCTs, such as the one demonstrated in this study, represent a viable methodology for experiments in CT.
Authors: Bernd J Wintersperger; Konstantin Nikolaou; Franz von Ziegler; Thorsten Johnson; Carsten Rist; Alexander Leber; Thomas Flohr; Andreas Knez; Maximilian F Reiser; Christoph R Becker Journal: Invest Radiol Date: 2006-05 Impact factor: 6.016
Authors: Michael M Lell; Matthias May; Paul Deak; Sedat Alibek; Michael Kuefner; Axel Kuettner; Henrik Köhler; Stephan Achenbach; Michael Uder; Tanja Radkow Journal: Invest Radiol Date: 2011-02 Impact factor: 6.016
Authors: Alex Zwanenburg; Martin Vallières; Mahmoud A Abdalah; Hugo J W L Aerts; Vincent Andrearczyk; Aditya Apte; Saeed Ashrafinia; Spyridon Bakas; Roelof J Beukinga; Ronald Boellaard; Marta Bogowicz; Luca Boldrini; Irène Buvat; Gary J R Cook; Christos Davatzikos; Adrien Depeursinge; Marie-Charlotte Desseroit; Nicola Dinapoli; Cuong Viet Dinh; Sebastian Echegaray; Issam El Naqa; Andriy Y Fedorov; Roberto Gatta; Robert J Gillies; Vicky Goh; Michael Götz; Matthias Guckenberger; Sung Min Ha; Mathieu Hatt; Fabian Isensee; Philippe Lambin; Stefan Leger; Ralph T H Leijenaar; Jacopo Lenkowicz; Fiona Lippert; Are Losnegård; Klaus H Maier-Hein; Olivier Morin; Henning Müller; Sandy Napel; Christophe Nioche; Fanny Orlhac; Sarthak Pati; Elisabeth A G Pfaehler; Arman Rahmim; Arvind U K Rao; Jonas Scherer; Muhammad Musib Siddique; Nanna M Sijtsema; Jairo Socarras Fernandez; Emiliano Spezi; Roel J H M Steenbakkers; Stephanie Tanadini-Lang; Daniela Thorwarth; Esther G C Troost; Taman Upadhaya; Vincenzo Valentini; Lisanne V van Dijk; Joost van Griethuysen; Floris H P van Velden; Philip Whybra; Christian Richter; Steffen Löck Journal: Radiology Date: 2020-03-10 Impact factor: 29.146
Authors: Constance A Owens; Christine B Peterson; Chad Tang; Eugene J Koay; Wen Yu; Dennis S Mackin; Jing Li; Mohammad R Salehpour; David T Fuentes; Laurence E Court; Jinzhong Yang Journal: PLoS One Date: 2018-10-04 Impact factor: 3.240