Literature DB >> 16532932

A computed tomography implementation of multiple-image radiography.

Jovan G Brankov1, Miles N Wernick, Yongyi Yang, Jun Li, Carol Muehleman, Zhong Zhong, Mark A Anastasio.   

Abstract

Conventional x-ray computed tomography (CT) produces a single volumetric image that represents the spatially variant linear x-ray attenuation coefficient of an object. However, in many situations, differences in the x-ray attenuation properties of soft tissues are very small and difficult to measure in conventional x-ray imaging. In this work, we investigate an analyzer-based imaging method, called computed tomography multiple-image radiography (CT-MIR), which is a tomographic implementation of the recently proposed multiple-image radiography method. The CT-MIR method reconstructs concurrently three physical properties of the object. In addition to x-ray attenuation, CT-MIR produces volumetric images that represent the refraction and ultrasmall-angle scattering properties of the object. These three images can provide a rich description of the object's physical properties that are revealed by the probing x-ray beam. An imaging model for CT-MIR that is based on the x-ray transform of the object properties is established. The CT-MIR method is demonstrated by use of experimental data acquired at a synchroton radiation imaging beamline, and is compared to the pre-existing diffraction-enhanced imaging CT method. We also investigate the merit of an iterative reconstruction method for use with future clinical implementations of CT-MIR, which we anticipate would be photon limited.

Entities:  

Mesh:

Year:  2006        PMID: 16532932     DOI: 10.1118/1.2150788

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  X-ray imaging of poly(ethylene glycol) hydrogels without contrast agents.

Authors:  Eric M Brey; Alyssa Appel; Yu-Chieh Chiu; Zhong Zhong; Ming-Huei Cheng; Holger Engel; Mark A Anastasio
Journal:  Tissue Eng Part C Methods       Date:  2010-07-27       Impact factor: 3.056

2.  Multi-modal hard x-ray imaging with a laboratory source using selective reflection from a mirror.

Authors:  Daniele Pelliccia; David M Paganin
Journal:  Biomed Opt Express       Date:  2014-03-12       Impact factor: 3.732

Review 3.  Potential for imaging engineered tissues with X-ray phase contrast.

Authors:  Alyssa Appel; Mark A Anastasio; Eric M Brey
Journal:  Tissue Eng Part B Rev       Date:  2011-08-02       Impact factor: 6.389

4.  Imaging of Hydrogel Microsphere Structure and Foreign Body Response Based on Endogenous X-Ray Phase Contrast.

Authors:  Alyssa A Appel; Veronica Ibarra; Sami I Somo; Jeffery C Larson; Alfred B Garson; Huifeng Guan; John Patrick McQuilling; Zhong Zhong; Mark A Anastasio; Emmanuel C Opara; Eric M Brey
Journal:  Tissue Eng Part C Methods       Date:  2016-11       Impact factor: 3.056

5.  An initial evaluation of analyser-based phase-contrast X-ray imaging of carotid plaque microstructure.

Authors:  A A Appel; C-Y Chou; J C Larson; Z Zhong; F J Schoen; C M Johnston; E M Brey; M A Anastasio
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

6.  X-ray Phase Contrast Allows Three Dimensional, Quantitative Imaging of Hydrogel Implants.

Authors:  Alyssa A Appel; Jeffery C Larson; Bin Jiang; Zhong Zhong; Mark A Anastasio; Eric M Brey
Journal:  Ann Biomed Eng       Date:  2015-10-20       Impact factor: 3.934

7.  Imaging of poly(α-hydroxy-ester) scaffolds with X-ray phase-contrast microcomputed tomography.

Authors:  Alyssa A Appel; Jeffery C Larson; Sami Somo; Zhong Zhong; Patrick P Spicer; F Kurtis Kasper; Alfred B Garson; Adam M Zysk; Antonios G Mikos; Mark A Anastasio; Eric M Brey
Journal:  Tissue Eng Part C Methods       Date:  2012-07-02       Impact factor: 3.056

8.  Volumetric Characterization of Human Patellar Cartilage Matrix on Phase Contrast X-Ray Computed Tomography.

Authors:  Anas Z Abidin; Mahesh B Nagarajan; Walter A Checefsky; Paola Coan; Paul C Diemoz; Susan K Hobbs; Markus B Huber; Axel Wismüller
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-19

9.  Analyzer-based phase-contrast x-ray imaging of carotid plaque microstructure.

Authors:  Alyssa A Appel; Cheng-Ying Chou; Howard P Greisler; Jeffery C Larson; Sunil Vasireddi; Zhong Zhong; Mark A Anastasio; Eric M Brey
Journal:  Am J Surg       Date:  2012-11       Impact factor: 2.565

10.  Noise and analyzer-crystal angular position analysis for analyzer-based phase-contrast imaging.

Authors:  Keivan Majidi; Jun Li; Carol Muehleman; Jovan G Brankov
Journal:  Phys Med Biol       Date:  2014-03-20       Impact factor: 3.609