| Literature DB >> 15604135 |
Jan R Heerman1, Patrick Segers, Carl D Roosens, Frank Gasthuys, Pascal R Verdonck, Jan I Poelaert.
Abstract
We studied whether combined pressure and transesophageal ultrasound monitoring is feasible in the intensive care unit (ICU) setting for global cardiovascular hemodynamic monitoring [systemic vascular resistance (SVR) and total arterial compliance (C(PPM))] and direct estimation of local ascending and descending aortic mechanical properties, i.e., distensibility and compliance coefficients (DC and CC). Pressure-area data were fitted to the arctangent Langewouters model, with aortic cross-sectional area obtained via automated border detection. Data were measured in 19 subjects at baseline, during infusion of sodium nitroprusside (SNP), and after washout. SNP infusion lowered SVR from 1.15 +/- 0.40 to 0.80 +/- 0.32 mmHg.ml(-1).s (P < 0.05), whereas C(PPM) increased from 0.87 +/- 0.46 to 1.02 +/- 0.42 ml/mmHg (P < 0.05). DC and CC increased from 0.0018 +/- 0.0007 to 0.0025 +/- 0.0009 l/mmHg (P < 0.05) and from 0.0066 +/- 0.0028 to 0.0083 +/- 0.0026 cm2/mmHg (P < 0.05), respectively, at the descending, but not ascending, aorta. The Langewouters model fitted the descending aorta data reasonably well. Assessment of local mechanical properties of the human ascending aorta in a clinical setting by automated border detection remains technically challenging.Entities:
Mesh:
Substances:
Year: 2004 PMID: 15604135 DOI: 10.1152/ajpheart.00368.2004
Source DB: PubMed Journal: Am J Physiol Heart Circ Physiol ISSN: 0363-6135 Impact factor: 4.733