Literature DB >> 25636421

Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients.

Jung Im Kim1, Chang Min Park, Sang Min Lee, Jin Mo Goo.   

Abstract

OBJECTIVES: To investigate the effect of rapid needle-out patient-rollover approach on the incidence of pneumothorax and drainage catheter placement due to pneumothorax in C-arm Cone-beam CT (CBCT)-guided percutaneous transthoracic needle biopsy (PTNB) of lung lesions.
METHODS: From May 2011 to December 2012, 1227 PTNBs were performed in 1191 patients with a 17-gauge coaxial needle. 617 biopsies were performed without (conventional-group) and 610 with rapid-rollover approach (rapid-rollover-group). Overall pneumothorax rates and incidences of pneumothorax requiring drainage catheter placement were compared between two groups.
RESULTS: There were no significant differences in overall pneumothorax rates between conventional and rapid-rollover groups (19.8% vs. 23.1%, p = 0.164). However, pneumothorax rate requiring drainage catheter placement was significantly lower in rapid-rollover-group (1.6%) than conventional-group (4.2%) (p = 0.010). Multivariate analysis revealed male, age > 60, bulla crossed, fissure crossed, pleura to target distance > 1.3 cm, emphysema along needle tract, and pleural punctures ≥ 2 were significant risk factors of pneumothorax (p < 0.05). Regarding pneumothorax requiring drainage catheter placement, fissure crossed, bulla crossed, and emphysema along needle tract were significant risk factors (p < 0.05), whereas rapid-rollover approach was an independent protective factor (p = 0.002).
CONCLUSIONS: The rapid needle-out patient-rollover approach significantly reduced the rate of pneumothorax requiring drainage catheter placement after CBCT-guided PTNB. KEY POINTS: • The rapid-rollover approach had little beneficial effect on overall pneumothorax rate. • The rapid-rollover approach significantly reduced drainage catheter placement due to pneumothorax. • The strongest risk factor was pleural punctures ≥ 2 per procedure. • Emphysema along the needle tract was a stronger risk factor than fissure-crossed.

Entities:  

Mesh:

Year:  2015        PMID: 25636421     DOI: 10.1007/s00330-015-3601-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  28 in total

1.  CT-guided transthoracic needle biopsy using a puncture site-down positioning technique.

Authors:  Fumiko Kinoshita; Takashi Kato; Kimihiko Sugiura; Masamichi Nishimura; Toshibumi Kinoshita; Masayuki Hashimoto; Toshio Kaminoh; Toshihide Ogawa
Journal:  AJR Am J Roentgenol       Date:  2006-10       Impact factor: 3.959

2.  Preventing pneumothorax after lung biopsy: the roll-over technique.

Authors:  D M Cassel; F A Birnberg
Journal:  Radiology       Date:  1990-01       Impact factor: 11.105

3.  Percutaneous transthoracic needle biopsy of small (≤ 1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance.

Authors:  Ji Yung Choo; Chang Min Park; Nyoung Keun Lee; Sang Min Lee; Hyun-Ju Lee; Jin Mo Goo
Journal:  Eur Radiol       Date:  2012-09-14       Impact factor: 5.315

4.  Positional precautions in needle aspiration lung biopsy.

Authors:  E H Moore; J A Shepard; T C McLoud; P A Templeton; J P Kosiuk
Journal:  Radiology       Date:  1990-06       Impact factor: 11.105

5.  Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors?

Authors:  J P Ko; J O Shepard; E A Drucker; S L Aquino; A Sharma; B Sabloff; E Halpern; T C McLoud
Journal:  Radiology       Date:  2001-02       Impact factor: 11.105

6.  Rapid needle-out patient-rollover time after percutaneous CT-guided transthoracic biopsy of lung nodules: effect on pneumothorax rate.

Authors:  Ailbhe C O'Neill; Colin McCarthy; Carole A Ridge; Patrick Mitchell; Emer Hanrahan; Marcus Butler; Michael P Keane; Jonathan D Dodd
Journal:  Radiology       Date:  2011-11-21       Impact factor: 11.105

7.  Risks of Transthoracic Needle Biopsy: How High?

Authors:  Renda Soylemez Wiener; Daniel C Wiener; Michael K Gould
Journal:  Clin Pulm Med       Date:  2013-01-01

8.  Effect of patient positioning after needle aspiration lung biopsy.

Authors:  E H Moore; J LeBlanc; S A Montesi; M L Richardson; J A Shepard; T C McLoud
Journal:  Radiology       Date:  1991-11       Impact factor: 11.105

9.  C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (≤ 20 mm) lung nodules: diagnostic accuracy and complications in 161 patients.

Authors:  Jin Woo Choi; Chang Min Park; Jin Mo Goo; Yang-Kyun Park; Wonmo Sung; Hyun-Ju Lee; Sang Min Lee; Ji Young Ko; Mi-Suk Shim
Journal:  AJR Am J Roentgenol       Date:  2012-09       Impact factor: 3.959

10.  Patient positioning after fine needle lung biopsy-effect on pneumothorax rate.

Authors:  K Tanisaro
Journal:  Acta Radiol       Date:  2003-01       Impact factor: 1.990

View more
  21 in total

1.  Where are we on (preventing) pneumothorax after (cone-beam) computed tomography-guided lung biopsy?

Authors:  Myrthe M Vestering; Sicco J Braak
Journal:  J Thorac Dis       Date:  2015-09       Impact factor: 2.895

2.  Is the rapid needle-out patient-rollover approach after CT-guided lung biopsy really effective for pneumothorax prevention?

Authors:  Zafar Neyaz; Namita Mohindra
Journal:  J Thorac Dis       Date:  2015-09       Impact factor: 2.895

3.  Safer lung biopsy techniques: fewer patients with pneumothorax, fewer chest tube insertions.

Authors:  Kamran Ahrar
Journal:  J Thorac Dis       Date:  2015-10       Impact factor: 2.895

4.  Rapid needle-out patient-rollover approach after CT-guided lung biopsy: challenges and future directions.

Authors:  Ailbhe C O'Neill; Neasa Ní Mhuircheartaigh; Jonathan D Dodd
Journal:  J Thorac Dis       Date:  2015-10       Impact factor: 2.895

5.  C-Arm Cone-Beam CT Virtual Navigation-Guided Percutaneous Mediastinal Mass Biopsy: Diagnostic Accuracy and Complications.

Authors:  Hyungjin Kim; Chang Min Park; Sang Min Lee; Jin Mo Goo
Journal:  Eur Radiol       Date:  2015-04-28       Impact factor: 5.315

6.  Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules.

Authors:  Nicola Rotolo; Chiara Floridi; Andrea Imperatori; Federico Fontana; Anna Maria Ierardi; Monica Mangini; Veronica Arlant; Giuseppe De Marchi; Raffaele Novario; Lorenzo Dominioni; Carlo Fugazzola; Gianpaolo Carrafiello
Journal:  Eur Radiol       Date:  2015-06-06       Impact factor: 5.315

Review 7.  Clinical utility of F-18 FDG PET-CT in the initial evaluation of lung cancer.

Authors:  Poul Henning Madsen; Paw Christian Holdgaard; Janne Buck Christensen; Poul Flemming Høilund-Carlsen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-05-11       Impact factor: 9.236

8.  Diagnostic feasibility and safety of CT-guided core biopsy for lung nodules less than or equal to 8 mm: A single-institution experience.

Authors:  Ying-Yueh Chang; Chun-Ku Chen; Yi-Chen Yeh; Mei-Han Wu
Journal:  Eur Radiol       Date:  2017-09-07       Impact factor: 5.315

9.  PERTINENT DRY NEEDLING CONSIDERATIONS FOR MINIMIZING ADVERSE EFFECTS - PART ONE.

Authors:  John S Halle; Rob J Halle
Journal:  Int J Sports Phys Ther       Date:  2016-08

10.  Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis.

Authors:  Judy U Ahrar; Sanjay Gupta; Joe E Ensor; Armeen Mahvash; Sharjeel H Sabir; Joseph R Steele; Stephen E McRae; Rony Avritscher; Steven Y Huang; Bruno C Odisio; Ravi Murthy; Kamran Ahrar; Michael J Wallace; Alda L Tam
Journal:  Cardiovasc Intervent Radiol       Date:  2016-11-08       Impact factor: 2.740

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.