Abstract

The authors performed 308 needle aspiration biopsies of parenchymal lung masses. The patients were then placed with the puncture site down for a period of at least 1 hour or until air leakage stopped. Coughing, talking, and activity were restricted. Complications included pneumothorax, at a rate of 25.0%, and chest tube placement, at a rate of 1.6%. In a subgroup of 262 patients who required only one pleural puncture at biopsy, a pneumothorax rate of 17.9% and a chest tube placement rate of 0.4% were encountered. When compared with a similar series of 143 control patients, significant reductions in both pneumothorax rate (P = .0004) and chest tube placement rate (P = .0001) were demonstrated.

Entities:  

Mesh:

Year:  1990        PMID: 2343123     DOI: 10.1148/radiology.175.3.2343123

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  12 in total

1.  Neuromuscular blockade with acute respiratory failure in a patient receiving cibenzoline.

Authors:  T Similowski; C Straus; V Attali; F Girard; F Philippe; G Deray; D Thomas; J P Derenne
Journal:  Thorax       Date:  1997-06       Impact factor: 9.139

2.  Delayed pneumothorax after CT-guided percutaneous fine needle aspiration lung biopsy.

Authors:  Z C Traill; F V Gleeson
Journal:  Thorax       Date:  1997-06       Impact factor: 9.139

3.  Guidelines for radiologically guided lung biopsy.

Authors:  A Manhire; M Charig; C Clelland; F Gleeson; R Miller; H Moss; K Pointon; C Richardson; E Sawicka
Journal:  Thorax       Date:  2003-11       Impact factor: 9.139

4.  Rapid needle-out patient-rollover approach after CT-guided lung biopsy: challenges and future directions.

Authors:  Ailbhe C O'Neill; Neasa Ní Mhuircheartaigh; Jonathan D Dodd
Journal:  J Thorac Dis       Date:  2015-10       Impact factor: 2.895

5.  A novel technique for CT-guided transthoracic biopsy of lung lesions: improved biopsy accuracy and safety.

Authors:  Daniel Yaffe; Matthew Koslow; Hassan Haskiya; David Shitrit
Journal:  Eur Radiol       Date:  2015-04-23       Impact factor: 5.315

6.  Percutaneous transthoracic needle biopsy: special considerations and techniques used in lung transplant recipients.

Authors:  Amanda B Wallace; Robert D Suh
Journal:  Semin Intervent Radiol       Date:  2004-12       Impact factor: 1.513

7.  Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients.

Authors:  Jung Im Kim; Chang Min Park; Sang Min Lee; Jin Mo Goo
Journal:  Eur Radiol       Date:  2015-02-01       Impact factor: 5.315

Review 8.  Transthoracic needle biopsy.

Authors:  G L Weisbrod
Journal:  World J Surg       Date:  1993 Nov-Dec       Impact factor: 3.352

Review 9.  Ultrathin needle (25 G) aspiration lung biopsy: diagnostic accuracy and complication rates.

Authors:  Anastasia Oikonomou; Frederick R Matzinger; Jean M Seely; Carole J Dennie; Peter J Macleod
Journal:  Eur Radiol       Date:  2003-10-09       Impact factor: 5.315

10.  Application of 3-Dimensionally Printed Coplanar Template Improves Diagnostic Yield of CT-Guided Percutaneous Core Needle Biopsy for Pulmonary Nodules.

Authors:  Hansheng Wang; Tao Ren; Peipei Chen; Guoshi Luo; Na Wei; Yijun Tang; Meifang Wang
Journal:  Technol Cancer Res Treat       Date:  2022 Jan-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.