Clinical and radiological results over the medium term of isolated acetabular revision.

Nicola Piolanti1, Lorenzo Andreani1, Paolo Domenico Parchi1, Enrico Bonicoli1, Francesco Niccolai1, Michele Lisanti1.   

Abstract

Acetabular cup loosening is associated with pain, reduced function, and instability of the implant. If such event happens while the femoral implant is in a satisfactory position and is well fixed to the bone, isolated acetabular revision surgery is indicated. The aim of this single-center retrospective study was to evaluate the clinical and radiological results over the medium term (12-month follow-up mean 36, max 60) of isolated acetabular revisions surgery using a porous hemispheric revision shell matched with a cemented all-poly cup and large diameter femoral head (>32). 33 patients were enrolled. We collect any relevant data from the clinical board. Routine clinical and radiographic examinations were performed preoperatively; the postoperative follow-up was made at 1, 3, and 6 months and yearly thereafter. At the last available follow-up, we report satisfactory improvement of functional scores in all the patients; 2 patients (6.1%) showed thigh pain and only 4 hips (12.11%) presented mild groin pain; all the femoral components are well fixed and there were no potential or pending rerevisions. With bias due to the follow-up and to the retrospective design of the study, we report clinical, functional, and radiological satisfactory results.

Entities:  

Mesh:

Year:  2014        PMID: 25610894      PMCID: PMC4295607          DOI: 10.1155/2014/148592

Source DB:  PubMed          Journal:  ScientificWorldJournal        ISSN: 1537-744X


1. Introduction

The most common reason for failure of total hip arthroplasty (THA) is periprosthetic osteolysis and loosening of hip implants [1]. The rate of osteolysis varies between femoral and acetabular sides, and it is more common on the acetabular side. This is why acetabular cup loosening is the main cause for revision in long-term studies [2]. This loosening usually is associated with pain, reduced function, and instability of the implant. There are two main problems to solve when an orthopaedic surgeon has to approach acetabular revision. First of all, even with bone loss due to the loosening of the previous implant, obtain primary fixation of the new prosthesis; then reach postoperative implant stability. This second issue could be more difficult when isolated acetabular revision is performed [3, 4]. Effectively in these cases not only does the presence of the stem limit surgical options, but also repeated surgical incision, soft tissue damage, and in some cases extended synovectomy can reduce the stability of the implant [5]. To address this risk, industries and surgeons have developed a variety of surgical hardware and strategies such as jumbo femoral heads [6], constrained acetabular liners [7] and dual-mobility cup [8]. Another way to face these problems is, in order to obtain fixation, the implantation of a shell in the better position allowed by the bone defect; then obtain stability cementing a polyethylene liner in the shell with a partially independent version and verticality. The present study was conducted to evaluate the clinical and radiological results over the medium term (>12-month follow-up mean 36, max 60) of isolated acetabular revisions surgery using a porous hemispheric revision shell matched with a cemented all-poly cup and large diameter femoral head (>32).

2. Material and Methods

This single-center retrospective study was approved by our local ethical committee, and the patients gave written consent to participate. A review of our database between January 2009 and December 2012 for revision hip arthroplasty was done. In this period we performed 86 THA revisions; we selected patients that had isolated acetabular revisions with a porous hemispheric revision shell matched with a cemented all-poly cup and large diameter femoral head (>32). Information of ages, sex, clinical history, drug treatment, and preoperative and postoperative X-ray studies were collected and recorded. The acetabular defects were classified as described by Paprosky et al. [9]. We included patients with (1) loosening or malpositions of the acetabular components, (2) a well fixed and well positioned femoral stem. We excluded (1) patients with septic loosening, (2) patients that required revision for both components, and (3) patients with monoblock stem. All the patients were operated on in the lateral decubitus position, and the surgical approach was posterolateral. We checked the stability of the stem and then we removed the acetabular cups, liners, and screws. If required before implantation of the revision components pelvic bony defects were grafted with tricalcium phosphate hydroxyapatite and morcelized bone graft. In all the index patients, the Regenerex revision shell (Biomet Warsaw, IN, USA) was implanted. This is a porous titanium construct, with multiple holes to maximize intraoperative screws fixation, designed to accept a cemented all-poly cup. During the revision surgery, the shell was implanted in the better position allowed by the bone defect; then in order to obtain the stability of the implant, the polyethylene liner was cemented into the shell in order to obtain verticality of about 45 degrees and summed of about 35 to 50 degrees of anteversion (stem plus liner) (Figure 1).
Figure 1

(a) α angle shows the correct acetabular anteversion reached after primary hip implant. (b) β angle obtained after revision hip surgery: the shell was implanted in the better position allowed by the bone defect. (c) During the revision surgery, in order to obtain the stability of the implant, the polyethylene liner was cemented into the shell in order to obtain the correct verticality and anteversion.

At the end of the surgical procedure, we obtained an intraoperative acceptable stability; in our opinion this is defined as 45° or more of internal rotation at 90° of flexion and 20° or more of external rotation in 10° of hyperextension. The wound was drained in each case. In the postoperative period all the patients performed thromboembolic prophylaxis, with low molecular weight heparin; we did not use nonsteroidal anti-inflammatory drugs to prevent heterotopic periprosthetic ossification. Partial weight bearing was allowed since the first postoperative week in the majority of patients; in some due to poor patient's bone stock we delayed it to the first radiological and clinical follow-up (six weeks) and gradually advanced it to full weight bearing. No postoperative bracing was used. Routine clinical and radiographic examinations were performed preoperatively; the postoperative follow-up was made at 1, 3, and 6 months and yearly thereafter. Patients were scored as routinely in our practice preoperatively with the Harris Hip Score (HHS) and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) [10, 11]; the same scores were used during the follow-up. As routinely during clinical evaluation, we collect and report data about any relevant adverse event that occurred; in addition we also investigate if there is thigh or groin pain, any subjective perception of instability, and subsequent apprehension. Radiographs were evaluated by two of the senior authors (Enrico Bonicoli and Paolo Domenico Parchi), with consensus attained for reporting of all measurements. The radiographic follow-up was performed in order to evaluate the position of the implant and to search for any signs of osseointegration or loosening of the components. The de Lee and Charnley classification [12] was used; radiolucent lines were considered present if they were greater than 1 mm at their maximum width and involved any two adjacent sectors of the cup surface [13]. A horizontal or vertical change in position of at least 3 mm, or a change in abduction angle of at least 5°, was considered migration [14]. According to Brooker et al., on the last available X-ray, we also evaluated heterotopic ossification [15]. The Wilcoxon signed-rank test was used to compare preoperative and postoperative hip scores.

3. Results

33 patients were enrolled for this study. There were 23 women (69,7%) and 10 men (30,3%); the mean age at the revisions was 67 years (range 40–81 years); 17 were left (51,5%) and 16 (48,5%) were right. The mean clinical follow-up was 36 months (minimum 13 months, maximum 60 months); one died from unrelated illnesses; 2 patients were lost to follow-up. The preoperative diagnoses were 26 with aseptic loosening (78,79%), 3 with implant instability (9,1%), and 4 revisions due to metallosis (12,11%). We treated 9 with type 1 defect of the Paprosky classification [9] (27%), 5 with type 2a (15%), 7 with type 2b (21%), 5 with type 2c (15%), and 7 with type 3a (21%). Cup trend was size 56, max size 68 and min size 54. In 13 patients, acetabular bone defects were grafted using tricalcium phosphate hydroxyapatite and morcelized bone graft (Figure 2); in 2 patients we used titanium augmentation. The mean number of screws used to secure the revision shells was five (from 3 to 7). The size of the femoral head was 32 (21 hips) and 36 mm (12 hips). See Table 1 for more details.
Figure 2

(a) Loosening of an acetabular press fit cup, stable stem. (b) Intraoperative picture showed bone defect grafted with tricalcium phosphate hydroxyapatite and morcelized bone graft. (c) Regenerex revision shell in place. (d) X-ray at the last available follow-up showing acetabular integration.

Table 1

Relevant data of the revised implant and data about the new components.

PatientSideSexAgePrevious implantImplantExplanted headDiagnosisCupPaproskySize cupScrew numberHeadGraft
1RightF72Press-fitUncemented28 metAseptic looseningRegenerex2 B544Cer 32Yes 
2RightF54Press-fitUncemented36 cerAseptic looseningRegenerex2 C565Cer 36Yes
3LeftF58Press-fitUncemented28 metImplant instabilityRegenerex2 A544Cer 32 Yes
4RightF64CementedCemented28 metAseptic looseningRegenerex2 A544Cer 32No
5LeftF61Press-fitUncemented36 metMetallosisRegenerex1544Cer 32 No
6RightF73Press-fitUncemented36 cerAseptic looseningRegenerex2 A545Cer 32No
7RightF77TreatedUncemented36 cerAseptic looseningRegenerex1585Cer 32No
8LeftM75CementedUncemented28 metAseptic looseningRegenerex2 C625Cer 36Yes
9LeftM73CementedCemented28 metAseptic looseningRegenerex3 A565Cer 32Yes
10LeftF74Press-fitUncemented28 cerAseptic looseningRegenerex2 B605Cer 32Yes
11LeftM64Press-fitUncemented36 cerImplant instabilityRegenerex1584Cer 32No
12LeftF46Press-fitUncemented28 cerAseptic looseningRegenerex2 B544Cer 32Yes
13LeftM78Press-fitUncemented28 cerAseptic looseningRegenerex2 B625Cer 36No
14RightM64TreatedUncemented36 cerAseptic looseningRegenerex2 A585Cer 36No
15RightF71CementedUncemented36 cerAseptic looseningRegenerex3 A564Cer 32Yes
16RightM64Press-fitUncemented32 cerAseptic looseningRegenerex2 B565Cer 32No
17RightF76CementedUncemented36 cerAseptic looseningRegenerex2 B566Cer 32No
18LeftF40Press-fitUncemented36 ceraAseptic looseningRegenerex1503Cer 32No
19LeftM74TreatedUncemented36 cerAseptic looseningRegenerex2 B626Cer 36No
20LeftM67Press-fitUncemented28 metImplant instabilityRegenerex1546Cer 32No
21RightM58Press-fitUncemented50 metMetallosisRegenerex1585Cer 36No
22RightF64Press-fitUncemented50 metMetallosisRegenerex1565Cer 36No
23LeftF72TreatedUncemented32 cerAseptic looseningRegenerex2 C608Cer 36Yes
24RightF79Press-fitCemented22 metAseptic looseningRegenerex3 A586Cer 32Yes
25RightF58Press-fitUncemented32 cerAseptic looseningRegenerex3 A567Cer 32Yes
26LeftF74Press-fitUncemented36 metAseptic looseningRegenerex2 A545cer 32No
27RightM74Press-fitUncemented22 metAseptic looseningRegenerex1686Cer 36No
28LeftF72Press-fitUncemented36 cerAseptic looseningRegenerex3 A567Cer 32Titanium augmentation
29LeftF81Press-fitCemented28 metAseptic looseningRegenerex3 A565Cer 32Titanium augmentation
30RightF63TreatedUncemented36 cerAseptic looseningRegenerex2 C605Cer 36No
31LeftF75CementedUncemented28 metAseptic looseningRegenerex2 C607Cer 36Yes
32RightF75Press-fitUncemented28 metAseptic looseningRegenerex3 A546Cer 32Yes
33LeftF59Press-fitUncemented40 metMetallosisRegenerex1586Cer 36No
Early complications (during the in-patient stay) occurred in 4 of the 33 patients (12,11%). These included a superficial wound infection in two, deep-vein thrombosis in one, and postoperative early dislocation in one. The postoperative early dislocation happened during a possible wrong movement of the patient from the operative room to the ward in a patient under spinal anesthesia. We reduced the dislocation with external manoeuvres and this event also at the last follow-up never happened again. The mean WOMAC score in 25 patients improved significantly from 52.1 preoperatively to 62.27 postoperatively (P = 0.008). The mean Harris Hip Score improved from 59 points (range 43–74) preoperatively to 88 points (range 67–92) (P = 0.002). At the final follow-up, 2 patients (6,1%) showed thigh pain and only 4 hips (12.11%) presented mild groin pain; all the femoral components are well fixed and there were no potential or pending rerevisions. With regard to the radiological evaluation, according to de Lee and Charnley [12], at the initial follow-up, we found 7 (21%) of the Regenerex implants with radiolucent lines bigger than 1 mm at their maximum width and which involved one or two adjacent sectors of the cup surface. In the last examination, five of the seven cases with radiolucent lines remaining still visible on the X-rays and seem not to be evolutive. In agreement with Schmalzried and Harris [16] and Petersen et al. [17], we attribute the filling of the gap to the formation of new bone (Figure 3).
Figure 3

(a) Postoperative radiographs showing radiolucent lines which involved two adjacent sectors of the cup surface. ((b), (c), and (d)) Progressive osseointegration during 3, 6, and 12 months' follow-up.

In 3 patients osteolysis around the screws was noted, without any change of the cup orientation and without evident evolution. No change of position was found. Even in our series it is not possible to establish the influence of bone grafting for the final stabilization of the implant; when it was used, good bone osseointegration was seen. Heterotopic ossification type 1-2 of Brooker classification [14] was found in 3 patients. We do not report major (>2 cm) leg length discrepancy. At the most recent follow-up no one patient had experienced a further dislocation.

4. Discussion

In this study we evaluate the clinical and radiological results over the medium term of isolated acetabular revision with a porous hemispheric revision shell matched with a cemented all-poly cup and large diameter femoral head (>32). Besides the lack of a control group there are some limitations in this study, such as the short follow-up of same patients and the retrospective design. However we think that our study can improve the literature's knowledge about this issue also because as reported in the Australian registry, the revision of the acetabular component is the most common cause of repeated surgery in total hip replacement [18]. Isolated acetabular revision is indicated when an acetabular implant is associated with pain, reduced function, instability, or loosening, while the femoral implant is in satisfactory position and is well fixed to bone. The benefits of leaving the femoral component in place include reduced operating time, less blood loss, and preservation of bone stock [19]. Doubtless the presence of the femoral implant limits the surgical exposure, making access to the acetabulum and treatment of bone defects challenging and increasing the risk of postoperative dislocation. The author's choice to face the problem of achieving fixation of the implant is to choose porous materials such as Regenerex during revision surgery. The advantage of these materials is not only to provide a primary stability due to scratch fit but also to allow long-term implant stability related to bone ingrowth (osteoconductivity) [20], which is important especially in revision surgery when bone quality is poor [21, 22]. Another advantage of such technique is to implant the shell in the better position allowed by the bone defect reaching the better possible primary stability and then cementing the polyethylene liner with version and verticality partially independent (Figure 2). In this way it is possible to obtain the correct geometry of the revised implant (verticality of about 45 degrees and summed of about 35° to 50 degrees of anteversion, stem plus liner) issue that is important to reduce the risk of dislocation which has been associated with hip revision surgery and rises in isolated acetabular revision. The author's opinion supported by biomechanical tests and several clinical series with short-term follow-up of liner cementation is that such technique is sure. The cemented polyethylene liner was found to have an initial fixation strength exceeding that of the conventional locking mechanism if 2 and 4 mm thick cement mantles were built up around the liner [18]. It is undisputed that large femoral heads improve stability of the hip implant by increasing the excursion before dislocation can occur [23]. The literature does not clarify whether any preoperative variables influence pain relief or functional scores [24]; however we report satisfactory improvement of functional scores (HHS improves from 59 to 88 and WOMAC from 52,1 to 62,27) with only 4 patients (12,11%) complaining of mild groin pain and 2 (6,1%) patients with thigh pain. We do not report major (>2 cm) leg length discrepancy. The only one dislocation (3%) is in-line or even better compared with the results reported from other authors [5–7, 24]; such dislocation appears to be correlated to a wrong patient transfer from the operative to the to the ward matched with spinal anesthesia. Schneider et al. [5] had 10 cases of dislocation (10.4%) in a series of 96 revisions with a reconstruction cage and a cemented dual-mobility cup. Della Valle et al. [7] in their series of 55 cases at a mean follow-up of 3,6 years reported a dislocation rate of 16%. Lawless et al. [24] reported a dislocation rate of 0% at 6,4 years after revision but with a 7,3% of reoperation due to aseptic loosening. With bias due to the follow-up and to the retrospective design of the study, in our series complications were low and we did not report reoperations, not only for the acetabular component but also for the stem; such results compare favorably with previous report [8, 25]. In our opinion, selective acetabular revision with a porous hemispheric revision shell matched with a cemented all-poly cup and large diameter femoral head is a reliable alternative with excellent clinical success over the medium term. Precise check of the preoperative X-rays and a careful evaluation of the intraoperative stem stability are mandatory for such results. Nevertheless more detailed and scrupulous evaluation with long-term prospective studies is needed.
  23 in total

1.  The fate of stable femoral components retained during isolated acetabular revision: a six-to-twelve-year follow-up study.

Authors:  Joseph T Moskal; Francis H Shen; Thomas E Brown
Journal:  J Bone Joint Surg Am       Date:  2002-02       Impact factor: 5.284

2.  Porous surface layered prosthetic devices.

Authors:  R M Pilliar; H U Cameron; I Macnab
Journal:  Biomed Eng       Date:  1975-04

3.  Femoral head size is a risk factor for total hip luxation: a study of 42,987 primary hip arthroplasties from the Norwegian Arthroplasty Register.

Authors:  Sven Byström; Birgitte Espehaug; Ove Furnes; Leif I Havelin
Journal:  Acta Orthop Scand       Date:  2003-10

4.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

5.  Evaluation of cementless acetabular component migration. An experimental study.

Authors:  P Massin; L Schmidt; C A Engh
Journal:  J Arthroplasty       Date:  1989-09       Impact factor: 4.757

6.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation.

Authors:  W H Harris
Journal:  J Bone Joint Surg Am       Date:  1969-06       Impact factor: 5.284

7.  Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee.

Authors:  N Bellamy; W W Buchanan; C H Goldsmith; J Campbell; L W Stitt
Journal:  J Rheumatol       Date:  1988-12       Impact factor: 4.666

8.  Ectopic ossification following total hip replacement. Incidence and a method of classification.

Authors:  A F Brooker; J W Bowerman; R A Robinson; L H Riley
Journal:  J Bone Joint Surg Am       Date:  1973-12       Impact factor: 5.284

9.  Multicenter clinical trials and their value in assessing total joint arthroplasty.

Authors:  P Herberts; L Ahnfelt; H Malchau; C Strömberg; G B Andersson
Journal:  Clin Orthop Relat Res       Date:  1989-12       Impact factor: 4.176

10.  Porous tantalum shells and augments for acetabular cup revisions.

Authors:  Andrej Moličnik; Marko Hanc; Gregor Rečnik; Zmago Krajnc; Mitja Rupreht; Samo K Fokter
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-16
View more
  2 in total

1.  Finite element model of the impaction of a press-fitted acetabular cup.

Authors:  Adrien Michel; Vu-Hieu Nguyen; Romain Bosc; Romain Vayron; Philippe Hernigou; Salah Naili; Guillaume Haiat
Journal:  Med Biol Eng Comput       Date:  2016-08-04       Impact factor: 2.602

2.  Hydroxyapatite in total hip arthroplasty. Our experience with a plasma spray porous titanium alloy/hydroxyapatite double-coated cementless stem.

Authors:  Iacopo Castellini; Lorenzo Andreani; Paolo Domenico Parchi; Enrico Bonicoli; Nicola Piolanti; Francesca Risoli; Michele Lisanti
Journal:  Clin Cases Miner Bone Metab       Date:  2017-02-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.