| Literature DB >> 25587389 |
Zahra Bahrololoomi1, Ali Asghar Soleimani2, Najmeh Jafari3, Bentolhoda Varkesh4.
Abstract
Background and aims. Newer curing units such as plasma arc can polymerize the sealants in much shorter curing times. The aim of this study was to compare the effect of two different curing units on the micro-leakage of a fissure sealant material. Materials and methods. Sixty two extracted premolars without caries were randomly divided into two groups of 31 samples. Occlusal surfaces of all teeth were cleansed. Then, teeth surfaces were etched by 37% phosphoric acid. After rinsing and drying, occlusal surfaces of teeth were sealed by a fissure sealant. The sealant was then cured using either a halogen light curing unit or a plasma arc curing light. After sealing, the teeth were thermocycled for 500 cycles. The teeth were then sectioned and examined for micro-leakage. Statistical analyses were performed with Mann-Whitney test. Results. There was no significant difference between two groups regarding micro-leakage (P = 0.42). Conclusion. Results showed that there was no significant difference between two different curing units. Therefore, plasma arc unit might be a useful alternative for sealant polymerization.Entities:
Keywords: Dental leakage; fissure sealants; polymerization
Year: 2014 PMID: 25587389 PMCID: PMC4288917 DOI: 10.5681/joddd.2014.045
Source DB: PubMed Journal: J Dent Res Dent Clin Dent Prospects ISSN: 2008-210X
Comparison of micro-leakage between two different methods in tooth sections evaluated (n = 124)
| Curing light unit | Mean ±SD | Median | Dye penetration score | |||||||
| 0 | 1 | 2 | 3 | |||||||
| n | % | n | % | n | % | n | % | |||
| Halogen | 0.88±1.2 | 0 | 76 | 61.26 | 8 | 6.45 | 19 | 15.32 | 21 | 16.93 |
| Plasma arc | 1.04±1.32 | 0 | 65 | 52.41 | 12 | 9.61 | 23 | 18.54 | 24 | 19.35 |
| Micro-leakage score: 0: no dye penetration; 1: dye penetration limited to the outer half of the sealant; 2: leakage up to the inner half of the sealant; 3: dye | ||||||||||
Comparison of micro-leakage between two different methods in the specimens evaluated (n = 31)
| Curing light unit | Mean ±SD | Median | Dye penetration score | |||||||
| 0 | 1 | 2 | 3 | |||||||
| n | % | n | % | n | % | n | % | |||
| Halogen | 1.32±1.24 | 1 | 12 | 38.7 | 5 | 16.12 | 6 | 19.35 | 8 | 25.8 |
| Plasma arc | 1.58±1.28 | 2 | 10 | 32.25 | 4 | 12.9 | 6 | 19.35 | 11 | 35.48 |
| Dye penetration score: 0: no dye penetration; 1: dye penetration limited to the outer half of the sealant; 2: leakage up to the inner half of the sealant; 3: | ||||||||||