Literature DB >> 18007102

Retention and penetration of a conventional resin-based sealant and a photochromatic flowable composite resin placed on occlusal pits and fissures.

F G Aguilar1, B Drubi-Filho, L A Casemiro, M G C Watanabe, F C P Pires-de-Souza.   

Abstract

This study compares the retention and penetration of a conventional resin-based sealant (Fluroshield) and a photochromatic flowable composite resin (Tetric Flow Chroma) placed on occlusal pits and fissures and submitted to thermal or chemical cycling regimens. Penetration assessment--ten premolars were sealed with each material, isolated (except for the sealed surface) and immersed in 0.2% Rhodamine B. The teeth were serially sectioned in a mesiodistal direction. The images of the sections were digitized and analyzed (ImageLab). The distance between the most superficial and the deepest points on the occlusal central groove was calculated to determine the groove's total depth. The length of the central groove filled with the sealant was divided by its total depth to obtain the percentage of sealing of the occlusal groove. Retention assessment--30 premolars were sealed, their occlusal surfaces were photographed and the area occupied by the sealing materials was demarcated (ImageLab). The teeth were submitted to different treatments: thermocycled, stored in artificial saliva and immersed in acetic acid and saliva (10 cycles/day protocol for 30 days). New photographs were taken to assess the final area occupied by the materials. The difference between the final and initial area was calculated to obtain the material loss. The data was analyzed (two-way ANOVA and Tukey's test P<0.05). Both materials presented similar penetration of the occlusal central groove. After thermal and chemical cycling, the materials did not differ with respect to retention, except for immersion in acetic acid. In this case, Tetric Flow Chroma presented greater retention than Fluoroshield.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18007102     DOI: 10.4103/0970-4388.37012

Source DB:  PubMed          Journal:  J Indian Soc Pedod Prev Dent        ISSN: 0970-4388


  11 in total

Review 1.  Flowable composite as fissure sealing material? A systematic review and meta-analysis.

Authors:  A Bagherian; A Sarraf Shirazi
Journal:  Br Dent J       Date:  2018-01-26       Impact factor: 1.626

Review 2.  Retention of pit and fissure sealants versus flowable composites in permanent teeth: A systematic review.

Authors:  Hasini Ramesh; Rupa Ashok; Mathan Rajan; Lakshmi Balaji; Arathi Ganesh
Journal:  Heliyon       Date:  2020-09-24

3.  Influence of extended light exposure curing times on the degree of conversion of resin-based pit and fissure sealant materials.

Authors:  Nazish Fatima
Journal:  Saudi Dent J       Date:  2014-07-10

4.  In vitro comparison of microleakage of two materials used as pit and fissure sealants.

Authors:  Zahra Bahrololoomi; Aliasghar Soleymani; Zahra Heydari
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2011-09-05

5.  Retention of a Flowable Composite Resin in Comparison to a Conventional Resin-Based Sealant: One-year Follow-up.

Authors:  M Jafarzadeh; B Malekafzali; N Tadayon; S Fallahi
Journal:  J Dent (Tehran)       Date:  2010-03-31

6.  Micro-leakage of a Fissure Sealant Cured Using Quartz-tungsten-halogen and Plasma Arc Light Curing Units.

Authors:  Zahra Bahrololoomi; Ali Asghar Soleimani; Najmeh Jafari; Bentolhoda Varkesh
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-12-03

7.  Evaluation of Marginal Microleakage and Depth of Penetration of Different Materials Used as Pit and Fissure Sealants: An In Vitro Study.

Authors:  Apra Butail; Parminder Dua; Ritu Mangla; Sheeba Saini; Ananya Chauhan; Swati Rana
Journal:  Int J Clin Pediatr Dent       Date:  2020 Jan-Feb

8.  An In Vitro Microleakage Study for Comparative Analysis of Two Types of Resin-based Sealants Placed by Using Three Different Types of Techniques of Enamel Preparation.

Authors:  Poonam Shingare; Vishwas Chaugule
Journal:  Int J Clin Pediatr Dent       Date:  2021 Jul-Aug

9.  Can extended photoactivation time of resin-based fissure sealer materials improve ultimate tensile strength and decrease water sorption/solubility?

Authors:  Boniek Castillo Dutra Borges; Eduardo José Souza-Júnior; Anderson Catelan; Luís Alexandre Maffei Sartini Paulillo; Flávio Henrique Baggio Aguiar
Journal:  Eur J Dent       Date:  2012-10

10.  Arrest of non-cavitated dentinal occlusal caries by sealing pits and fissures: a 36-month, randomised controlled clinical trial.

Authors:  Boniek Castillo Dutra Borges; Juliane de Souza Borges; Rodivan Braz; Marcos Antônio Japiassú Resende Montes; Isauremi Vieira de Assunção Pinheiro
Journal:  Int Dent J       Date:  2012-06-14       Impact factor: 2.607

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.