Andrés F Vallejo1, Nora L Martínez1, Iveth J González2, Myriam Arévalo-Herrera3, Sócrates Herrera1.
Abstract
BACKGROUND: Most commonly used malaria diagnostic tests, including microscopy and antigen-detecting rapid tests, cannot reliably detect low-density infections which are frequent in low transmission settings. Molecular methods such as polymerase chain reaction (PCR) are highly sensitive but remain too laborious for field deployment. In this study, the applicability of a malaria diagnosis kit based on loop-mediated isothermal amplification (mLAMP) was assessed in malaria endemic areas of Colombia with Plasmodium vivax predominance. METHODOLOGY/PRINCIPALEntities:
Mesh:
Substances:
Year: 2015 PMID: 25569550 PMCID: PMC4287555 DOI: 10.1371/journal.pntd.0003453
Source DB: PubMed Journal: PLoS Negl Trop Dis ISSN: 1935-2727
Demographics of study population in Tierralta, Buenaventura, and Tumaco.
| Passive case detection | Active case detection | |||
| N | % | n | % | |
| No participants | 278 | 100 | 980 | 100 |
| Male sex | 168 | 60.4 | 398 | 40.6 |
| Age 0–4 | 3 | 1.1 | 65 | 6.6 |
| Age 5–17 | 63 | 22.6 | 345 | 35.2 |
| Age >18 | 212 | 76.3 | 567 | 57.9 |
Colombia. April to December 2013.
Diagnostic performance of microscopy and mLAMP kit (Pan and Pf reaction tubes) for passive case detection (PCD) and compared to 3-well nested RT-PCR as reference standard (n = 278).
| Method and Parasite species | Parameter | % | 95% CI |
| Microscopy | Sensitivity | 86.1 | 66.0 to 83.5 |
|
| Specificity | 97.6 | 97.8 to 99.0 |
| PPV | 74.8 | 65.2 to 82.8 | |
| NPV | 98.5 | 97.8 to 99.0 | |
| Microscopy | Sensitivity | 100 | 69.2 to 100 |
|
| Specificity | 99.3 | 97.3 to 99.9 |
| PPV | 38.6 | 51.6 to 97.9 | |
| NPV | 99.3 | 98.6 to 100 | |
| Pan-mLAMP | Sensitivity | 91.4 | 82.3 to 96.8 |
|
| Specificity | 91.8 | 87.2 to 95.1 |
| PPV | 80.5 | 68.5 to 87.2 | |
| NPV | 99.6 | 93.5 to 98.9 | |
| Pan-mLAMP | Sensitivity | 100 | 69.2 to 100 |
|
| Specificity | 98.9 | 96.7 to 99.7 |
| PPV | 76.9 | 44.8 to 95.4 | |
| NPV | 100 | 98.6 to 100 | |
| Pf-mLAMP | Sensitivity | 100 | 69.2% to 100 |
|
| Specificity | 99.3 | 97.3% to 99.9 |
| PPV | 83.3 | 51.6% to 97.9 | |
| NPV | 100 | 98.6% to 100 | |
| Microscopy | Sensitivity | 86.1 | 66.0 to 83.5 |
|
| Specificity | 97.6 | 97.8 to 99.0 |
| PPV | 74.8 | 65.2 to 82.8 | |
| NPV | 98.5 | 97.8 to 99.0 | |
| Microscopy | Sensitivity | 100 | 69.2 to 100 |
|
| Specificity | 99.3 | 97.3 to 99.9 |
| PPV | 38.6 | 51.6 to 97.9 | |
| NPV | 99.3 | 98.6 to 100 | |
| Pan-mLAMP | Sensitivity | 91.4 | 82.3 to 96.8 |
|
| Specificity | 91.8 | 87.2 to 95.1 |
| PPV | 80.5 | 68.5 to 87.2 | |
| NPV | 99.6 | 93.5 to 98.9 | |
| Pan-mLAMP | Sensitivity | 100 | 69.2 to 100 |
|
| Specificity | 98.9 | 96.7 to 99.7 |
| PPV | 76.9 | 44.8 to 95.4 | |
| NPV | 100 | 98.6 to 100 | |
| Pf-mLAMP | Sensitivity | 100 | 69.2% to 100 |
|
| Specificity | 99.3 | 97.3% to 99.9 |
| PPV | 83.3 | 51.6% to 97.9 | |
| NPV | 100 | 98.6% to 100 |
Diagnostic performance of microscopy and Pan-mLAMP kit for active case detection (ACD) of asymptomatic infections and compared to 3-well nested RT-PCR as reference standard (n = 980).
| Method and Parasite species | Parameter | % | 95% CI |
| Microscopy | Sensitivity | 0 | 0 to 6.5 |
|
| Specificity | 100 | 99.6 to 100 |
| PPV | — | ||
| NPV | 9.4 | 92.80 to 95.7 | |
| Microscopy | Sensitivity | 5.9 | 0.2 to 28.7 |
|
| Specificity | 99.9 | 99.4 to 100 |
| PPV | 50.0 | 0.04 to 99.9 | |
| NPV | 98.4 | 97.36 to 99.0 | |
| Pan-mLAMP | Sensitivity | 90.9 | 80.0 to 97.0 |
|
| Specificity | 99.5 | 98.7 to 99.8 |
| PPV | 90.9 | 79.9 to 97.0 | |
| NPV | 99.5 | 98.7 to 99.8 | |
| Pan-mLAMP | Sensitivity | 100 | 78.2 to 100 |
| Specificity | 99.9 | 99.4 to 100 | |
|
| PPV | 93.8 | 69.8 to 99.8 |
| NPV | 100 | 99.6 to 100 |