Literature DB >> 25569459

Integrated microfluidic capillary electrophoresis-electrospray ionization devices with online MS detection for the separation and characterization of intact monoclonal antibody variants.

Erin A Redman1, Nicholas G Batz, J Scott Mellors, J Michael Ramsey.   

Abstract

Here, we demonstrate an integrated microfluidic capillary electrophoresis-electrospray ionization (CE-ESI) device for the separation of intact monoclonal antibody charge variants with online mass spectrometric (MS) identification. The need for dynamic coating and zwitterionic background electrolyte (BGE) additives has been eliminated by utilizing surface chemistry within the device channels to control analyte adsorption and electroosmotic flow (EOF) while maintaining separation efficiency. The effectiveness of this strategy was illustrated with the separation of charge variants of Infliximab. Three major species corresponding to C-terminal lysine variants were separated with an average resolution of 0.80 and identified by mass difference. In addition to the lysine variants, masses were determined for minor acidic and basic species. The separation of these variants prior to MS analysis facilitated the identification of glycosylation patterns for each of the variants. The general applicability of this method was demonstrated by analyzing two additional monoclonal antibody species: an IgG2 antibody and an IgG1 antibody conjugate. The IgG2 proved to have similar modifications to Infliximab with lower relative abundances of the lysine variants. Analysis of the IgG1 drug conjugate further exemplified the advantages of MS detection; differences in the extent of antibody conjugation were detectable despite limited CE resolution. The CE-ESI-MS methodology described here is a rapid and generic strategy for the separation of intact mAb charge variants and facilitates the identification of variants through MS detection.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25569459     DOI: 10.1021/ac503964j

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  18 in total

1.  Portable, Battery Operated Capillary Electrophoresis with Optical Isomer Resolution Integrated with Ionization Source for Mass Spectrometry.

Authors:  Mehdi Moini; Christopher M Rollman
Journal:  J Am Soc Mass Spectrom       Date:  2015-12-07       Impact factor: 3.109

2.  Utilizing Microchip Capillary Electrophoresis Electrospray Ionization for Hydrogen Exchange Mass Spectrometry.

Authors:  William A Black; Bradley B Stocks; J Scott Mellors; John R Engen; J Michael Ramsey
Journal:  Anal Chem       Date:  2015-06-02       Impact factor: 6.986

3.  Comparison of originator and biosimilar therapeutic monoclonal antibodies using comprehensive two-dimensional liquid chromatography coupled with time-of-flight mass spectrometry.

Authors:  Matthew Sorensen; David C Harmes; Dwight R Stoll; Gregory O Staples; Szabolcs Fekete; Davy Guillarme; Alain Beck
Journal:  MAbs       Date:  2016-06-30       Impact factor: 5.857

Review 4.  Recent advances in microfluidic sample preparation and separation techniques for molecular biomarker analysis: A critical review.

Authors:  Mukul Sonker; Vishal Sahore; Adam T Woolley
Journal:  Anal Chim Acta       Date:  2017-07-24       Impact factor: 6.558

5.  Microfluidic Capillary Electrophoresis-Mass Spectrometry for Analysis of Monosaccharides, Oligosaccharides, and Glycopeptides.

Authors:  Kshitij Khatri; Joshua A Klein; John R Haserick; Deborah R Leon; Catherine E Costello; Mark E McComb; Joseph Zaia
Journal:  Anal Chem       Date:  2017-06-06       Impact factor: 6.986

Review 6.  Recent advances in protein analysis by capillary and microchip electrophoresis.

Authors:  Mohamed Dawod; Natalie E Arvin; Robert T Kennedy
Journal:  Analyst       Date:  2017-05-30       Impact factor: 4.616

Review 7.  Recent trends of capillary electrophoresis-mass spectrometry in proteomics research.

Authors:  Fabio P Gomes; John R Yates
Journal:  Mass Spectrom Rev       Date:  2019-08-12       Impact factor: 10.946

8.  Integrated Electrodes and Electrospray Emitter for Polymer Microfluidic Nanospray-MS Interface.

Authors:  Anna V Forzano; Vedada Becirovic; R Scott Martin; James L Edwards
Journal:  Anal Methods       Date:  2016-06-01       Impact factor: 2.896

9.  Low Flow Voltage Free Interface for Capillary Electrophoresis and Mass Spectrometry Driven by Vibrating Sharp-Edge Spray Ionization.

Authors:  Courtney J Kristoff; Chong Li; Peng Li; Lisa A Holland
Journal:  Anal Chem       Date:  2020-02-07       Impact factor: 6.986

10.  Investigating native capillary zone electrophoresis-mass spectrometry on a high-end quadrupole-time-of-flight mass spectrometer for the characterization of monoclonal antibodies.

Authors:  Xiaojing Shen; Zhijie Liang; Tian Xu; Zhichang Yang; Qianjie Wang; Daoyang Chen; Lucynda Pham; Wenjun Du; Liangliang Sun
Journal:  Int J Mass Spectrom       Date:  2021-01-30       Impact factor: 1.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.