Literature DB >> 31958147

Accuracy of deformable image registration techniques for alignment of longitudinal cholangiocarcinoma CT images.

Anando Sen1, Brian M Anderson1, Guillaume Cazoulat1, Molly M McCulloch1, Dalia Elganainy2, Brigid A McDonald3, Yulun He1, Abdallah S R Mohamed2, Baher A Elgohari2, Mohamed Zaid2, Eugene J Koay2, Kristy K Brock1,3.   

Abstract

PURPOSE: Response assessment of radiotherapy for the treatment of intrahepatic cholangiocarcinoma (IHCC) across longitudinal images is challenging due to anatomical changes. Advanced deformable image registration (DIR) techniques are required to correlate corresponding tissues across time. In this study, the accuracy of five commercially available DIR algorithms in four treatment planning systems (TPS) was investigated for the registration of planning images with posttreatment follow-up images for response assessment or re-treatment purposes.
METHODS: Twenty-nine IHCC patients treated with hypofractionated radiotherapy and with pretreatment and posttreatment contrast-enhanced computed tomography (CT) images were analyzed. Liver segmentations were semiautomatically generated on all CTs and the posttreatment CT was then registered to the pretreatment CT using five commercially available algorithms (Demons, B-splines, salient feature-based, anatomically constrained and finite element-based) in four TPSs. This was followed by an in-depth analysis of 10 DIR strategies (plus global and liver-focused rigid registration) in one of the TPSs. Eight of the strategies were variants of the anatomically constrained DIR while the two were based on a finite element-based biomechanical registration. The anatomically constrained techniques were combinations of: (a) initializations with the two rigid registrations; (b) two similarity metrics - correlation coefficient (CC) and mutual information (MI); and (c) with and without a controlling region of interest (ROI) - the liver. The finite element-based techniques were initialized by the two rigid registrations. The accuracy of each registration was evaluated using target registration error (TRE) based on identified vessel bifurcations. The results were statistically analyzed with a one-way analysis of variance (ANOVA) and pairwise comparison tests. Stratified analysis was conducted on the inter-TPS data (plus the liver-focused rigid registration) using treatment volume changes, slice thickness, time between scans, and abnormal lab values as stratifying factors.
RESULTS: The complex deformation observed following treatment resulted in average TRE exceeding the image voxel size for all techniques. For the inter-TPS comparison, the Demons algorithm had the lowest TRE, which was significantly superior to all the other algorithms. The respective mean (standard deviation) TRE (in mm) for the Demons, B-splines, salient feature-based, anatomically constrained, and finite element-based algorithms were 4.6 (2.0), 7.4 (2.7), 7.2 (2.6), 6.3 (2.3), and 7.5 (4.0). In the follow-up comparison of the anatomically constrained DIR, the strategy with liver-focused rigid registration initialization, CC as similarity metric and liver as a controlling ROI had the lowest mean TRE - 6.0 (2.0). The maximum TRE for all techniques exceeded 10 mm. Selection of DIR strategy was found to be a statistically significant factor for registration accuracy. Tumor volume change had a significant effect on TRE for finite element-based registration and B-splines DIR. Time between scans had a substantial effect on TRE for all registrations but was only significant for liver-focused rigid, finite element-based and salient feature-based DIRs.
CONCLUSIONS: This study demonstrates the limitations of commercially available DIR techniques in TPSs for alignment of longitudinal images of liver cancer presenting complex anatomical changes including local hypertrophy and fibrosis/necrosis. DIR in this setting should be used with caution and careful evaluation.
© 2020 American Association of Physicists in Medicine.

Entities:  

Keywords:  biomechanical registration; cholangiocarcinoma; deformable image registration; liver cancer; treatment planning systems

Mesh:

Year:  2020        PMID: 31958147      PMCID: PMC7288249          DOI: 10.1002/mp.14029

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  The ANACONDA algorithm for deformable image registration in radiotherapy.

Authors:  Ola Weistrand; Stina Svensson
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

2.  Semiautomated registration of pre- and intraoperative CT for image-guided percutaneous liver tumor ablation interventions.

Authors:  Gokhan Gunay; Manh Ha Luu; Adriaan Moelker; Theo van Walsum; Stefan Klein
Journal:  Med Phys       Date:  2017-06-13       Impact factor: 4.071

3.  Chemotherapy improves survival and quality of life in advanced pancreatic and biliary cancer.

Authors:  B Glimelius; K Hoffman; P O Sjödén; G Jacobsson; H Sellström; L K Enander; T Linné; C Svensson
Journal:  Ann Oncol       Date:  1996-08       Impact factor: 32.976

4.  Validation of an accelerated 'demons' algorithm for deformable image registration in radiation therapy.

Authors:  He Wang; Lei Dong; Jennifer O'Daniel; Radhe Mohan; Adam S Garden; K Kian Ang; Deborah A Kuban; Mark Bonnen; Joe Y Chang; Rex Cheung
Journal:  Phys Med Biol       Date:  2005-06-01       Impact factor: 3.609

5.  GIFTed Demons: deformable image registration with local structure-preserving regularization using supervoxels for liver applications.

Authors:  Bartłomiej W Papież; James M Franklin; Mattias P Heinrich; Fergus V Gleeson; Michael Brady; Julia A Schnabel
Journal:  J Med Imaging (Bellingham)       Date:  2018-04-04

6.  Implementing Radiation Dose-Volume Liver Response in Biomechanical Deformable Image Registration.

Authors:  Daniel F Polan; Mary Feng; Theodore S Lawrence; Randall K Ten Haken; Kristy K Brock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-06-27       Impact factor: 7.038

7.  Worldwide trends in mortality from biliary tract malignancies.

Authors:  Tushar Patel
Journal:  BMC Cancer       Date:  2002-05-03       Impact factor: 4.430

Review 8.  Functional imaging for radiotherapy treatment planning: current status and future directions-a review.

Authors:  D Thorwarth
Journal:  Br J Radiol       Date:  2015-04-01       Impact factor: 3.039

Review 9.  Intrahepatic cholangiocarcinoma: current perspectives.

Authors:  Stefan Buettner; Jeroen LA van Vugt; Jan Nm IJzermans; Bas Groot Koerkamp
Journal:  Onco Targets Ther       Date:  2017-02-22       Impact factor: 4.147

10.  Comparison of rigid and deformable registration through the respiratory phases of four-dimensional computed tomography image data sets for radiotherapy after breast-conserving surgery.

Authors:  Aiping Zhang; Jianbin Li; Heng Qiu; Wei Wang; Yanluan Guo
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817

View more
  3 in total

1.  Detection of vessel bifurcations in CT scans for automatic objective assessment of deformable image registration accuracy.

Authors:  Guillaume Cazoulat; Brian M Anderson; Molly M McCulloch; Bastien Rigaud; Eugene J Koay; Kristy K Brock
Journal:  Med Phys       Date:  2021-08-25       Impact factor: 4.506

2.  Volumetric Quantitative Ablation Margins for Assessment of Ablation Completeness in Thermal Ablation of Liver Tumors.

Authors:  Raluca-Maria Sandu; Iwan Paolucci; Simeon J S Ruiter; Raphael Sznitman; Koert P de Jong; Jacob Freedman; Stefan Weber; Pascale Tinguely
Journal:  Front Oncol       Date:  2021-03-10       Impact factor: 6.244

3.  Comparison of an in-house hybrid DIR method to NiftyReg on CBCT and CT images for head and neck cancer.

Authors:  Chunling Jiang; Yuling Huang; Shenggou Ding; Xiaochang Gong; Xingxing Yuan; Shaobin Wang; Jingao Li; Yun Zhang
Journal:  J Appl Clin Med Phys       Date:  2022-01-27       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.