Literature DB >> 25496544

The left atrial appendage: anatomy, function, and noninvasive evaluation.

Roy Beigel1, Nina C Wunderlich2, Siew Yen Ho3, Reza Arsanjani4, Robert J Siegel5.   

Abstract

The left atrial appendage (LAA) is a finger-like extension originating from the main body of the left atrium. Atrial fibrillation (AF) is the most common clinically important cardiac arrhythmia, occurring in approximately 0.4% to 1% of the general population and increasing with age to >8% in those >80 years of age. In the presence of AF thrombus, formation often occurs within the LAA because of reduced contractility and stasis; thus, attention should be given to the LAA when evaluating and assessing patients with AF to determine the risk for cardioembolic complications. It is clinically important to understand LAA anatomy and function. It is also critical to choose the optimal imaging techniques to identify or exclude LAA thrombi in the setting of AF, before cardioversion, and with current and emerging transcatheter therapies, which include mitral balloon valvuloplasty, pulmonary vein isolation, MitraClip (Abbott Laboratories, Abbott Park, Illinois) valve repair, and the implantation of LAA occlusion and exclusion devices. In this review, we present the current data regarding LAA anatomy, LAA function, and LAA imaging using the currently available noninvasive imaging modalities.
Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  anatomy; function; left atrial appendage; noninvasive imaging; thromboembolism

Mesh:

Year:  2014        PMID: 25496544     DOI: 10.1016/j.jcmg.2014.08.009

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  86 in total

Review 1.  Atrial cardiopathy: a mechanism of cryptogenic stroke.

Authors:  Shadi Yaghi; Hooman Kamel; Mitchell S V Elkind
Journal:  Expert Rev Cardiovasc Ther       Date:  2017-07-27

2.  Intracardiac echocardiography for verification for left atrial appendage thrombus presence detected by transesophageal echocardiography: the ActionICE II study.

Authors:  Jakub Baran; Beata Zaborska; Roman Piotrowski; Malgorzata Sikora-Frąc; Ewa Pilichowska-Paszkiet; Piotr Kułakowski
Journal:  Clin Cardiol       Date:  2017-02-13       Impact factor: 2.882

3.  Early results of first versus second generation Amplatzer occluders for left atrial appendage closure in patients with atrial fibrillation.

Authors:  Steffen Gloekler; Samera Shakir; Janosch Doblies; Ahmed A Khattab; Fabien Praz; Ênio Guerios; Dezsoe Koermendy; Stefan Stortecky; Thomas Pilgrim; Lutz Buellesfeld; Peter Wenaweser; Stephan Windecker; Aris Moschovitis; Milosz Jaguszewski; Ulf Landmesser; Fabian Nietlispach; Bernhard Meier
Journal:  Clin Res Cardiol       Date:  2015-03-04       Impact factor: 5.460

4.  The value of the left atrial appendage orifice perimeter of 3D model based on 3D TEE data in the choice of device size of LAmbre™ occluder.

Authors:  Dan Jia; Qing Zhou; Hong-Ning Song; Lan Zhang; Jin-Ling Chen; Yu Liu; Bin Kong; Fa-Zhi He; Yi-Jia Wang; Yuan-Ting Yang
Journal:  Int J Cardiovasc Imaging       Date:  2019-05-27       Impact factor: 2.357

Review 5.  [Imaging in structural heart disease : Impact on interventional therapy].

Authors:  A Schmermund; J Eckert; S N Schelle; H Eggebrecht
Journal:  Herz       Date:  2016-11       Impact factor: 1.443

6.  Vascular Landmark-Based Method for Highly Reproducible Measurement of Left Atrial Appendage Volume in Computed Tomography.

Authors:  Andrew Schluchter; Chelsea Jan; Katherine Lowe; Davis M Vigneault; Francisco Contijoch; Elliot R McVeigh
Journal:  Circ Cardiovasc Imaging       Date:  2019-12-17       Impact factor: 7.792

Review 7.  Left Atrial Occlusion Device Implantation: the Role of the Echocardiographer.

Authors:  David Altszuler; Alan F Vainrib; Daniel G Bamira; Ricardo J Benenstein; Anthony Aizer; Larry A Chinitz; Muhamed Saric
Journal:  Curr Cardiol Rep       Date:  2019-06-10       Impact factor: 2.931

8.  Left atrial appendage pericardial fluid: contrast-enhanced transesophageal echocardiography makes it visible.

Authors:  V Kamperidis; E Michou; K Kouskouras; O Nikolaidou; H Karvounis
Journal:  Hippokratia       Date:  2016 Jul-Sep       Impact factor: 0.471

9.  Impact of left atrial appendage closure on cardiac functional and structural remodeling: A difference-in-difference analysis of propensity score matched samples.

Authors:  Quang Tan Phan; Seung-Yong Shin; Ik-Sung Cho; Wang-Soo Lee; Hoyoun Won; Saima Sharmin; Dong-Young Lee; Tae-Ho Kim; Chee-Jeong Kim; Sang-Wook Kim
Journal:  Cardiol J       Date:  2018-05-02       Impact factor: 2.737

10.  Correlation between plasma brain natriuretic peptide levels and left atrial appendage flow velocity in patients with non-valvular atrial fibrillation and normal left ventricular systolic function.

Authors:  Masahiko Harada; Satoshi Tabako; Yuichiro Fujii; Yuichi Takarada; Kyoko Hayashi; Hiroshi Ohara; Fumihiko Hara; Takanori Ikeda
Journal:  J Echocardiogr       Date:  2017-12-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.