Literature DB >> 28191906

Intracardiac echocardiography for verification for left atrial appendage thrombus presence detected by transesophageal echocardiography: the ActionICE II study.

Jakub Baran1, Beata Zaborska1, Roman Piotrowski1, Malgorzata Sikora-Frąc1, Ewa Pilichowska-Paszkiet1, Piotr Kułakowski1.   

Abstract

BACKGROUND: Transesophageal echocardiography (TEE) remains the gold standard for exclusion of left atrial appendage (LAA) thrombus in patients scheduled for direct electrical cardioversion (DEC) or atrial fibrillation (AF) ablation. Recently, intracardiac echocardiography (ICE) of the pulmonary artery (PA) has been shown to provide excellent LAA images and to be useful in verification of equivocal TEE findings. HYPOTHESIS: ICE of the PA may have a role in detecting false-positive TEE results.
METHODS: Twenty-one patients (12 male, age 65 ± 8 years, CHADS2VASC2 score [congestive heart failure, hypertension, age ≥ 75, age 65-74, diabetes mellitus, stroke/TIA/thrombo-embolism, vascular disease, sex female] = 2.2; HAS-BLED score [hypertension, abnormal renal and liver function, stroke, bleeding, labile International Normalized Ratio, elderly, drugs or alcohol] = 1.1), in whom a thrombus in the LAA was detected during TEE before DEC or AF ablation, underwent ICE of the PA.
RESULTS: On TEE, in 7 (33%) patients, the LAA thrombus was described as "solid" and in the remaining 14 (67%) as "soft." Disagreement between the TEE and ICE (thrombus in TEE and no thrombus in ICE) was found in 9 (43%) patients. In the solid thrombus group, ICE confirmed thrombi existence in 6 and excluded thrombi in 1 patient. In the soft thrombus group, ICE confirmed thrombi in 6 patients and excluded thrombi in the remaining 8 patients. Of the demographic and clinical variables, only the longstanding persistent type of AF was significantly associated with the presence of an LAA thrombus detected both by TEE and ICE.
CONCLUSIONS: With TEE, a false positive of an LAA thrombus may be indicated, especially when a thrombus is described as soft rather than solid. Our study suggests that ICE may be a valuable option for verification of a TEE-based diagnosis of a thrombus.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  atrial fibrillation; intracardiac echocardiography; thrombus; transesophageal echocardiography

Mesh:

Year:  2017        PMID: 28191906      PMCID: PMC6490372          DOI: 10.1002/clc.22675

Source DB:  PubMed          Journal:  Clin Cardiol        ISSN: 0160-9289            Impact factor:   2.882


  12 in total

1.  Intracardiac echocardiography for verification for left atrial appendage thrombus presence detected by transesophageal echocardiography: the ActionICE II study.

Authors:  Jakub Baran; Beata Zaborska; Roman Piotrowski; Malgorzata Sikora-Frąc; Ewa Pilichowska-Paszkiet; Piotr Kułakowski
Journal:  Clin Cardiol       Date:  2017-02-13       Impact factor: 2.882

2.  Incidence of Stroke or Systemic Embolism in Paroxysmal Versus Sustained Atrial Fibrillation: The Fushimi Atrial Fibrillation Registry.

Authors:  Kensuke Takabayashi; Yasuhiro Hamatani; Yugo Yamashita; Daisuke Takagi; Takashi Unoki; Mitsuru Ishii; Moritake Iguchi; Nobutoyo Masunaga; Hisashi Ogawa; Masahiro Esato; Yeong-Hwa Chun; Hikari Tsuji; Hiromichi Wada; Koji Hasegawa; Mitsuru Abe; Gregory Y H Lip; Masaharu Akao
Journal:  Stroke       Date:  2015-10-29       Impact factor: 7.914

3.  Residual Risk of Stroke and Death in Anticoagulated Patients According to the Type of Atrial Fibrillation: AMADEUS Trial.

Authors:  Keitaro Senoo; Gregory Y H Lip; Deirdre A Lane; Harry R Büller; Dipak Kotecha
Journal:  Stroke       Date:  2015-07-23       Impact factor: 7.914

Review 4.  The left atrial appendage: anatomy, function, and noninvasive evaluation.

Authors:  Roy Beigel; Nina C Wunderlich; Siew Yen Ho; Reza Arsanjani; Robert J Siegel
Journal:  JACC Cardiovasc Imaging       Date:  2014-12

5.  An alternative transseptal intracardiac echocardiography strategy to guide left atrial appendage closure: the first described case.

Authors:  Gaetano Fassini; Antonio Dello Russo; Sergio Conti; Claudio Tondo
Journal:  J Cardiovasc Electrophysiol       Date:  2014-08-04

Review 6.  Diagnosis of left atrial thrombi in mitral stenosis--usefulness of ultrasound techniques compared with other methods.

Authors:  J Acar; B Cormier; D Grimberg; G Kawthekar; B Iung; B Scheuer; E Farah
Journal:  Eur Heart J       Date:  1991-07       Impact factor: 29.983

7.  Intracardiac echocardiographic diagnosis of thrombus formation in the left atrial appendage: a complementary role to transesophageal echocardiography.

Authors:  Jian-Fang Ren; Francis E Marchlinski; Gregory E Supple; Mathew D Hutchinson; Fermin C Garcia; Michael P Riley; David Lin; Erica S Zado; David J Callans; Victor A Ferrari
Journal:  Echocardiography       Date:  2012-09-25       Impact factor: 1.724

8.  Comparison of intracardiac echocardiography and transesophageal echocardiography for imaging of the right and left atrial appendages.

Authors:  Elad Anter; Joshua Silverstein; Cory M Tschabrunn; Alexei Shvilkin; Charles I Haffajee; Peter J Zimetbaum; Alfred E Buxton; Mark E Josephson; Eli Gelfand; Warren J Manning
Journal:  Heart Rhythm       Date:  2014-07-14       Impact factor: 6.343

9.  Is transesophageal echocardiogram mandatory in patients undergoing ablation of atrial fibrillation with uninterrupted novel oral anticoagulants? Results from a prospective multicenter registry.

Authors:  Luigi Di Biase; David F Briceno; Chintan Trivedi; Sanghamitra Mohanty; Carola Gianni; J David Burkhardt; Prasant Mohanty; Rong Bai; Sampath Gunda; Rodney Horton; Shane Bailey; Javier E Sanchez; Amin Al-Ahmad; Patrick Hranitzky; G Joseph Gallinghouse; Yaruva Madhu Reddy; Jason Zagrodzky; Richard Hongo; Salwa Beheiry; Dhanunjaya Lakkireddy; Andrea Natale
Journal:  Heart Rhythm       Date:  2016-03-16       Impact factor: 6.343

10.  Accuracy of transesophageal echocardiography for identifying left atrial thrombi. A prospective, intraoperative study.

Authors:  W J Manning; R M Weintraub; C A Waksmonski; J M Haering; P S Rooney; A D Maslow; R G Johnson; P S Douglas
Journal:  Ann Intern Med       Date:  1995-12-01       Impact factor: 25.391

View more
  4 in total

1.  Intracardiac echocardiography for verification for left atrial appendage thrombus presence detected by transesophageal echocardiography: the ActionICE II study.

Authors:  Jakub Baran; Beata Zaborska; Roman Piotrowski; Malgorzata Sikora-Frąc; Ewa Pilichowska-Paszkiet; Piotr Kułakowski
Journal:  Clin Cardiol       Date:  2017-02-13       Impact factor: 2.882

2.  Combined use of electro-anatomic mapping system and intracardiac echocardiography to achieve zero-fluoroscopy catheter ablation for treatment of paroxysmal atrial fibrillation: a single centre experience.

Authors:  Matevž Jan; David Žižek; Dimitrij Kuhelj; Nikola Lakič; Tine Prolič Kalinšek; Jernej Štublar; Luka Klemen; Andrej Pernat; Bor Antolič
Journal:  Int J Cardiovasc Imaging       Date:  2019-11-11       Impact factor: 2.357

3.  Current Safety of Pulmonary Vein Isolation in Paroxysmal Atrial Fibrillation: First Experience of Same Day Discharge.

Authors:  Dr Mondragon Ignacio; Dr Joaquín J Jarma; Vecchio Nicolas; Daquarti Gustavo; Tomas Leandro; Caro Milagros; Elias Vasquez; Giniger Alberto; Rivera Santiago; Albina Gaston; Scazzuso Fernando
Journal:  J Atr Fibrillation       Date:  2018-12-31

4.  Comparison of transesophageal and intracardiac echocardiography in guiding percutaneous left atrial appendage closure with an Amplatzer Amulet device.

Authors:  Witold Streb; Katarzyna Mitręga; Tomasz Podolecki; Stanisław Morawski; Mariola Szulik; Ewa Jędrzejczyk-Patej; Tomasz Kukulski; Zbigniew Kalarus
Journal:  Postepy Kardiol Interwencyjnej       Date:  2019-12-08       Impact factor: 1.426

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.