Literature DB >> 25492093

Reverse-polynomial dilution calibration methodology extends lower limit of quantification and reduces relative residual error in targeted peptide measurements in blood plasma.

Yunki Y Yau1, Xizi Duo2, Rupert W L Leong3, Valerie C Wasinger4.   

Abstract

Matrix effect is the alteration of an analyte's concentration-signal response caused by co-existing ion components. With electrospray ionization (ESI), matrix effects are believed to be a function of the relative concentrations, ionization efficiency, and solvation energies of the analytes within the electrospray ionization droplet. For biological matrices such as plasma, the interactions between droplet components is immensely complex and the effect on analyte signal response not well elucidated. This study comprised of three sequential quantitative analyses: we investigated whether there is a generalizable correlation between the range of unique ions in a sample matrix (complexity); the amount of matrix components (concentration); and matrix effect, by comparing an E. coli digest matrix (∼2600 protein proteome) with phospholipid depleted human blood plasma, and unfractionated, nondepleted human plasma matrices (∼10(7) proteome) for six human plasma peptide multiple reaction monitoring assays. Our data set demonstrated analyte-specific interactions with matrix complexity and concentration properties resulting in significant ion suppression for all peptides (p < 0.01), with nonuniform effects on the ion signals of the analytes and their stable-isotope analogs. These matrix effects were then assessed for translation into relative residual error and precision effects in a low concentration (∼0-250 ng/ml) range across no-matrix, complex matrix, and highly complex matrix, when a standard addition stable isotope dilution calibration method was used. Relative residual error (%) and precision (CV%) by stable isotope dilution were within <20%; however, error in phospholipid-depleted and nondepleted plasma matrices were significantly higher compared with no-matrix (p = 0.006). Finally a novel reverse-polynomial dilution calibration method with and without phospholipid-depletion was compared with stable isotope dilution for relative residual error and precision. Reverse-polynomial dilution techniques extend the Lower Limit of Quantification and reduce error (p = 0.005) in low-concentration plasma peptide assays and is broadly applicable for verification phase Tier 2 multiplexed multiple reaction monitoring assay development within the FDA-National Cancer Institute (NCI) biomarker development pipeline.
© 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25492093      PMCID: PMC4350038          DOI: 10.1074/mcp.M114.040790

Source DB:  PubMed          Journal:  Mol Cell Proteomics        ISSN: 1535-9476            Impact factor:   5.911


  36 in total

1.  Mechanistic investigation of ionization suppression in electrospray ionization.

Authors:  R King; R Bonfiglio; C Fernandez-Metzler; C Miller-Stein; T Olah
Journal:  J Am Soc Mass Spectrom       Date:  2000-11       Impact factor: 3.109

2.  A study of ion suppression effects in electrospray ionization from mobile phase additives and solid-phase extracts.

Authors:  Claude R Mallet; Ziling Lu; Jeff R Mazzeo
Journal:  Rapid Commun Mass Spectrom       Date:  2004       Impact factor: 2.419

3.  Quantitation of endogenous analytes in biofluid without a true blank matrix.

Authors:  Wenlin Li; Lucinda H Cohen
Journal:  Anal Chem       Date:  2003-11-01       Impact factor: 6.986

Review 4.  Protein biomarker discovery and validation: the long and uncertain path to clinical utility.

Authors:  Nader Rifai; Michael A Gillette; Steven A Carr
Journal:  Nat Biotechnol       Date:  2006-08       Impact factor: 54.908

Review 5.  Stable-isotope dilution LC–MS for quantitative biomarker analysis.

Authors:  Eugene Ciccimaro; Ian A Blair
Journal:  Bioanalysis       Date:  2010-02       Impact factor: 2.681

6.  Multi-site assessment of the precision and reproducibility of multiple reaction monitoring-based measurements of proteins in plasma.

Authors:  Terri A Addona; Susan E Abbatiello; Birgit Schilling; Steven J Skates; D R Mani; David M Bunk; Clifford H Spiegelman; Lisa J Zimmerman; Amy-Joan L Ham; Hasmik Keshishian; Steven C Hall; Simon Allen; Ronald K Blackman; Christoph H Borchers; Charles Buck; Helene L Cardasis; Michael P Cusack; Nathan G Dodder; Bradford W Gibson; Jason M Held; Tara Hiltke; Angela Jackson; Eric B Johansen; Christopher R Kinsinger; Jing Li; Mehdi Mesri; Thomas A Neubert; Richard K Niles; Trenton C Pulsipher; David Ransohoff; Henry Rodriguez; Paul A Rudnick; Derek Smith; David L Tabb; Tony J Tegeler; Asokan M Variyath; Lorenzo J Vega-Montoto; Asa Wahlander; Sofia Waldemarson; Mu Wang; Jeffrey R Whiteaker; Lei Zhao; N Leigh Anderson; Susan J Fisher; Daniel C Liebler; Amanda G Paulovich; Fred E Regnier; Paul Tempst; Steven A Carr
Journal:  Nat Biotechnol       Date:  2009-06-28       Impact factor: 54.908

7.  Matrix effect in quantitative LC/MS/MS analyses of biological fluids: a method for determination of finasteride in human plasma at picogram per milliliter concentrations.

Authors:  B K Matuszewski; M L Constanzer; C M Chavez-Eng
Journal:  Anal Chem       Date:  1998-03-01       Impact factor: 6.986

8.  Phospholipids in liquid chromatography/mass spectrometry bioanalysis: comparison of three tandem mass spectrometric techniques for monitoring plasma phospholipids, the effect of mobile phase composition on phospholipids elution and the association of phospholipids with matrix effects.

Authors:  Yuan-Qing Xia; Mohammed Jemal
Journal:  Rapid Commun Mass Spectrom       Date:  2009-07       Impact factor: 2.419

9.  Targeted peptide measurements in biology and medicine: best practices for mass spectrometry-based assay development using a fit-for-purpose approach.

Authors:  Steven A Carr; Susan E Abbatiello; Bradley L Ackermann; Christoph Borchers; Bruno Domon; Eric W Deutsch; Russell P Grant; Andrew N Hoofnagle; Ruth Hüttenhain; John M Koomen; Daniel C Liebler; Tao Liu; Brendan MacLean; D R Mani; Elizabeth Mansfield; Hendrik Neubert; Amanda G Paulovich; Lukas Reiter; Olga Vitek; Ruedi Aebersold; Leigh Anderson; Robert Bethem; Josip Blonder; Emily Boja; Julianne Botelho; Michael Boyne; Ralph A Bradshaw; Alma L Burlingame; Daniel Chan; Hasmik Keshishian; Eric Kuhn; Christopher Kinsinger; Jerry S H Lee; Sang-Won Lee; Robert Moritz; Juan Oses-Prieto; Nader Rifai; James Ritchie; Henry Rodriguez; Pothur R Srinivas; R Reid Townsend; Jennifer Van Eyk; Gordon Whiteley; Arun Wiita; Susan Weintraub
Journal:  Mol Cell Proteomics       Date:  2014-01-17       Impact factor: 5.911

10.  HybridSPE: A novel technique to reduce phospholipid-based matrix effect in LC-ESI-MS Bioanalysis.

Authors:  Shafeeque Ahmad; Harsh Kalra; Amit Gupta; Bharat Raut; Arshad Hussain; Md Akhlaquer Rahman
Journal:  J Pharm Bioallied Sci       Date:  2012-10
View more
  2 in total

1.  Serological Epithelial Component Proteins Identify Intestinal Complications in Crohn's Disease.

Authors:  Yunki Y Yau; Rupert W L Leong; Aviv Pudipeddi; Diane Redmond; Valerie C Wasinger
Journal:  Mol Cell Proteomics       Date:  2017-05-10       Impact factor: 5.911

2.  Low Mass Blood Peptides Discriminative of Inflammatory Bowel Disease (IBD) Severity: A Quantitative Proteomic Perspective.

Authors:  Valerie C Wasinger; Yunki Yau; Xizi Duo; Ming Zeng; Beth Campbell; Sean Shin; Raphael Luber; Diane Redmond; Rupert W L Leong
Journal:  Mol Cell Proteomics       Date:  2015-11-03       Impact factor: 5.911

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.