Literature DB >> 19517478

Phospholipids in liquid chromatography/mass spectrometry bioanalysis: comparison of three tandem mass spectrometric techniques for monitoring plasma phospholipids, the effect of mobile phase composition on phospholipids elution and the association of phospholipids with matrix effects.

Yuan-Qing Xia1, Mohammed Jemal.   

Abstract

Because plasma phospholipids may cause matrix effects in bioanalytical liquid chromatography/tandem mass spectrometry (LC/MS/MS) methods, it is important to establish optimal mass spectrometric techniques to monitor the fate of phospholipids during method development and application. We evaluated three MS/MS techniques to monitor phospholipids using positive and negative electrospray ionization (ESI). The first technique is based on using positive precursor ion scan of m/z 184, positive neutral loss scan of 141 Da and negative precursor ion scan of m/z 153. The second technique is based on using class-specific positive and negative selected reaction monitoring (SRM) transitions to monitor class-representative phospholipids. The third technique, previously reported, utilizes in-source collision-induced dissociation (CID)-based positive SRM of m/z 184 --> 184. We recommend the all-inclusive technique 1 for use in qualitative assessment of all classes of phospholipids and technique 2 for use in quantitative assessment of class-representative phospholipids. Secondly, we evaluated the elution behaviors of the plasma phospholipids under different reversed-phase mobile phase conditions. The phospholipid-eluting strength of a mobile phase was mainly dependent on the type and amount (%) of the organic eluent and the strength increased in the order of methanol, acetonitrile and isopropyl alcohol. Under the commonly used gradient and isocratic elution schemes in LC/MS/MS bioanalysis, not all the phospholipids are eluted off the column. Thirdly, we investigated the association between phospholipids and matrix effects in positive and negative ESI using basic, acidic and neutral analytes. While the phospholipids caused matrix effects in both positive and negative ESI, the extent of ionization suppression was analyte-dependent and was inversely related to the retention factor and broadness of the phospholipids peaks. The lysophospholipids which normally elute earlier in reversed-phase chromatography are more likely to cause matrix effects compared to the later-eluting phospholipids in spite of the larger concentrations of the latter in plasma. Copyright 2009 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19517478     DOI: 10.1002/rcm.4121

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  19 in total

1.  Reverse-polynomial dilution calibration methodology extends lower limit of quantification and reduces relative residual error in targeted peptide measurements in blood plasma.

Authors:  Yunki Y Yau; Xizi Duo; Rupert W L Leong; Valerie C Wasinger
Journal:  Mol Cell Proteomics       Date:  2014-12-09       Impact factor: 5.911

Review 2.  Biological Matrix Effects in Quantitative Tandem Mass Spectrometry-Based Analytical Methods: Advancing Biomonitoring.

Authors:  Parinya Panuwet; Ronald E Hunter; Priya E D'Souza; Xianyu Chen; Samantha A Radford; Jordan R Cohen; M Elizabeth Marder; Kostya Kartavenka; P Barry Ryan; Dana Boyd Barr
Journal:  Crit Rev Anal Chem       Date:  2016       Impact factor: 6.535

3.  Direct quantification of cannabinoids and cannabinoid glucuronides in whole blood by liquid chromatography-tandem mass spectrometry.

Authors:  David M Schwope; Karl B Scheidweiler; Marilyn A Huestis
Journal:  Anal Bioanal Chem       Date:  2011-07-05       Impact factor: 4.142

4.  Utilizing Internal Standard Responses to Assess Risk on Reporting Bioanalytical Results from Hemolyzed Samples.

Authors:  Eliza N Fung; Anne-Françoise Aubry; Alban Allentoff; Qin C Ji
Journal:  AAPS J       Date:  2015-05-15       Impact factor: 4.009

5.  Sphingolipids Modulate Secretion of Glycosylphosphatidylinositol-Anchored Plasmodesmata Proteins and Callose Deposition.

Authors:  Arya Bagus Boedi Iswanto; Jong Cheol Shon; Kwang Hyeon Liu; Minh Huy Vu; Ritesh Kumar; Jae-Yean Kim
Journal:  Plant Physiol       Date:  2020-07-07       Impact factor: 8.340

6.  Rapid identification of plasmalogen molecular species using targeted multiplexed selected reaction monitoring mass spectrometry.

Authors:  Abul Kalam Azad; Hironori Kobayashi; Abdullah Md Sheikh; Harumi Osago; Hiromichi Sakai; Md Ahsanul Haque; Shozo Yano; Atsushi Nagai
Journal:  J Mass Spectrom Adv Clin Lab       Date:  2021-10-07

7.  Comprehensive analysis of LC/MS data using pseudocolor plots.

Authors:  Christopher A Crutchfield; Matthew T Olson; Evgenia Gourgari; Maria Nesterova; Constantine A Stratakis; Alfred L Yergey
Journal:  J Am Soc Mass Spectrom       Date:  2013-01-03       Impact factor: 3.109

8.  Using Visualized Matrix Effects to Develop and Improve LC-MS/MS Bioanalytical Methods, Taking TRAM-34 as an Example.

Authors:  Jia-Hung Ye; Li-Heng Pao
Journal:  PLoS One       Date:  2015-04-24       Impact factor: 3.240

9.  A metabolomic investigation of the effects of vitamin E supplementation in humans.

Authors:  Max Wong; John K Lodge
Journal:  Nutr Metab (Lond)       Date:  2012-12-19       Impact factor: 4.169

10.  Validation of a LC-MS/MS method for quantifying urinary nicotine, six nicotine metabolites and the minor tobacco alkaloids--anatabine and anabasine--in smokers' urine.

Authors:  James E McGuffey; Binnian Wei; John T Bernert; John C Morrow; Baoyun Xia; Lanqing Wang; Benjamin C Blount
Journal:  PLoS One       Date:  2014-07-11       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.