Literature DB >> 9511465

Matrix effect in quantitative LC/MS/MS analyses of biological fluids: a method for determination of finasteride in human plasma at picogram per milliliter concentrations.

B K Matuszewski1, M L Constanzer, C M Chavez-Eng.   

Abstract

Contrary to common perceptions, the reliability of quantitative assays for the determination of drugs in biological fluids using high-performance liquid chromatography with tandem mass spectrometric (LC/MS/MS) detection methods and the integrity of resulting pharmacokinetic data may not be absolute. Results may be adversely affected by lack of specificity and selectivity due to ion suppression caused by the sample matrix, interferences from metabolites, and "cross-talk" effects. In this paper, an example of the effect of the sample matrix on the determination of finasteride (I) in human plasma is presented. The ion suppression effect was studied by analyzing standards of I injected directly in mobile phase and comparing the response (peak areas) of I and an internal standard (II) with the peak areas of the same analytes spiked before extraction into five different plasma pools and standards spiked into the plasma extracts after extraction. The LC/MS/MS analyses were performed using a turbo ion spray interface (TISP) under chromatographic conditions, characterized by minimal (total run time of 2 min, capacity factors, k' of 1.50 and 1.75 for I and II, respectively) and high retention of the analytes (total run time 6 min, k' of 3.25 and 13.25 for I and II, respectively). The absolute peak areas for I and II in different plasmas were calculated, and the slopes and peak area ratios at all concentrations within the standard curve ranges were compared. When analyses were performed under conditions of minimal HPLC retention, the slope of the standard line for one set of plasma samples was substantially different (about 50% higher) from that from other plasma sources. The precision of the assay, expressed as coefficient of variation (CV, %) was also inadequate and varied from 15 to 30% at all concentrations within the standard curve range. When the same experiments were repeated using high HPLC retention, the slopes from different plasma sources were practically the same, and the CV was improved to 6-14%. By increasing k' and providing more chromatographic retention of analytes, the "unseen" interferences from plasma matrix were mostly separated from analytes, practically eliminating the ion suppression. In addition, by eliminating from plasma extracts a number of endogenous components through more selective extraction, the ion suppression was also minimized. The detailed data and the design of these experiments are presented. In addition, development of a highly sensitive assay for I in human plasma at low picogram per milliliter concentrations using LC/MS/MS with a heated nebulizer (HN) interface, instead of a TISP interface, is described. In this case, the effects of sample matrixes were not observed.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9511465     DOI: 10.1021/ac971078+

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  74 in total

1.  High-throughput sample preparation and analysis using 96-well membrane solid-phase extraction and liquid chromatography-tandem mass spectrometry for the determination of steroids in human urine.

Authors:  G Rule; J Henion
Journal:  J Am Soc Mass Spectrom       Date:  1999-12       Impact factor: 3.109

2.  Mass spectral fragmentation reactions of a therapeutic 4-azasteroid and related compounds.

Authors:  D J Burinsky; J D Williams; A D Thornquest; S L Sides
Journal:  J Am Soc Mass Spectrom       Date:  2001-04       Impact factor: 3.109

3.  Mechanistic investigation of ionization suppression in electrospray ionization.

Authors:  R King; R Bonfiglio; C Fernandez-Metzler; C Miller-Stein; T Olah
Journal:  J Am Soc Mass Spectrom       Date:  2000-11       Impact factor: 3.109

4.  Global metabolic profiling procedures for urine using UPLC-MS.

Authors:  Elizabeth J Want; Ian D Wilson; Helen Gika; Georgios Theodoridis; Robert S Plumb; John Shockcor; Elaine Holmes; Jeremy K Nicholson
Journal:  Nat Protoc       Date:  2010-06       Impact factor: 13.491

5.  Simultaneous HPLC-MS-MS quantification of 8-iso-PGF(2alpha) and 8,12-iso-iPF(2alpha) in CSF and brain tissue samples with on-line cleanup.

Authors:  Magdalena Korecka; Christopher M Clark; Virginia M-Y Lee; John Q Trojanowski; Leslie M Shaw
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2010-07-01       Impact factor: 3.205

6.  Evaluation of different quantitative approaches for the determination of noneasily ionizable molecules by different atmospheric pressure interfaces used in liquid chromatography tandem mass spectrometry: abamectin as case of study.

Authors:  Susana Grimalt; Oscar J Pozo; Jose M Marín; Juan V Sancho; Félix Hernández
Journal:  J Am Soc Mass Spectrom       Date:  2005-10       Impact factor: 3.109

7.  Oral Cannabidiol Does Not Convert to Δ8-THC or Δ9-THC in Humans: A Pharmacokinetic Study in Healthy Subjects.

Authors:  José Alexandre S Crippa; Antonio Waldo Zuardi; Jaime Eduardo Cecílio Hallak; Bruna Miyazawa; Sandra Aparecido Bernardo; Carmem Maria Donaduzzi; Silvane Guzzi; Wagner Alex Jann Favreto; Alline Campos; Maria Eugênia C Queiroz; Francisco S Guimarães; Patrícia Moura da Rosa Zimmermann; Letícia Mello Rechia; Volnei Jose Tondo Filho; Liberato Brum Junior
Journal:  Cannabis Cannabinoid Res       Date:  2020-02-27

8.  High-throughput pharmacokinetic method: cassette dosing in mice associated with minuscule serial bleedings and LC/MS/MS analysis.

Authors:  Takaho Watanabe; Daniela Schulz; Christophe Morisseau; Bruce D Hammock
Journal:  Anal Chim Acta       Date:  2006-02-10       Impact factor: 6.558

9.  An LC-IMS-MS platform providing increased dynamic range for high-throughput proteomic studies.

Authors:  Erin Shammel Baker; Eric A Livesay; Daniel J Orton; Ronald J Moore; William F Danielson; David C Prior; Yehia M Ibrahim; Brian L LaMarche; Anoop M Mayampurath; Athena A Schepmoes; Derek F Hopkins; Keqi Tang; Richard D Smith; Mikhail E Belov
Journal:  J Proteome Res       Date:  2010-02-05       Impact factor: 4.466

Review 10.  Clinical review: improving the measurement of serum thyroglobulin with mass spectrometry.

Authors:  Andrew N Hoofnagle; Mara Y Roth
Journal:  J Clin Endocrinol Metab       Date:  2013-02-28       Impact factor: 5.958

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.