Literature DB >> 25491591

Accuracy of predicted refraction with multifocal intraocular lenses using two biometry measurement devices and multiple intraocular lens power calculation formulas.

Olga Reitblat1,2, Ehud I Assia1,3,4, Guy Kleinmann1,2,5, Adi Levy1, Graham D Barrett6, Adi Abulafia1,4,6.   

Abstract

BACKGROUND: To evaluate the accuracy of predicted refraction using multifocal intraocular lenses (IOLs) with power calculation based on two biometric devices and multiple IOL power calculation formulas.
DESIGN: A retrospective study conducted in a private practice ophthalmology clinic. PARTICIPANTS: Seventy-three eyes of 48 patients were evaluated.
METHODS: Consecutive cases of eyes that had undergone successful cataract surgery with an implantation of a multifocal IOL (SN6AD1, Alcon Laboratories, Inc., Fort Worth, TX, USA) by a single surgeon were enrolled. Patients were meticulously screened for suitability for a multifocal IOL implantation according to our clinic guidelines. Two biometric measurement devices (IOLMaster-500 [Carl Zeiss Meditec AG, Jena, Germany] and Lenstar-LS900 [Haag-Streit AG, Koeniz, Switzerland]) were used under strict validation criteria to evaluate the predicted refraction errors for the Holladay 1, SRK/T, Hoffer Q, Haigis, Holladay 2, Barrett Universal II and Olsen formulas. MAIN OUTCOME MEASURES: Predicted refractive sphere equivalent (RSE) errors.
RESULTS: The measurements obtained from the two biometric devices were highly correlated. The standard deviation of the error in predicted RSE and the median absolute error were similar for the IOLMaster and the Lenstar devices using all formulas, ranging from 0.27 dioptres (D) to 0.31D and from 0.15D to 0.21D, respectively. A high percentage of eyes had an error in predicted RSE within ±0.5D from target refraction, ranging from 86.3% to 93.2%.
CONCLUSIONS: High accuracy can be achieved in multifocal IOL power calculations by appropriate patient selection, precise biometry and appropriate IOL calculation formulas.
© 2014 Royal Australian and New Zealand College of Ophthalmologists.

Entities:  

Keywords:  biometry; cataract; intraocular lens (IOL); multifocal IOL

Mesh:

Year:  2015        PMID: 25491591     DOI: 10.1111/ceo.12478

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  12 in total

1.  Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens.

Authors:  Jing Zhao; Liang-Ping Liu; Huan-Huan Cheng; Jian-Bing Li; Xiao-Tong Han; Yu Liu; Ming-Xing Wu
Journal:  Int J Ophthalmol       Date:  2020-09-18       Impact factor: 1.779

2.  [Comparison of two optical biometric devices for intraocular lens calculation].

Authors:  M-S Uckmann; M Stattin; C Zehetner; S Neururer; L Speicher
Journal:  Ophthalmologe       Date:  2019-03       Impact factor: 1.059

3.  Meta-analysis of optical low-coherence reflectometry versus partial coherence interferometry biometry.

Authors:  Jinhai Huang; Colm McAlinden; Yingying Huang; Daizong Wen; Giacomo Savini; Ruixue Tu; Qinmei Wang
Journal:  Sci Rep       Date:  2017-02-24       Impact factor: 4.379

4.  Accuracy of optical biometry combined with Placido disc corneal topography for intraocular lens power calculation.

Authors:  Giacomo Savini; Kenneth J Hoffer; Piero Barboni; Nicole Balducci; Domenico Schiano-Lomoriello; Pietro Ducoli
Journal:  PLoS One       Date:  2017-02-23       Impact factor: 3.240

5.  Influence of pupil dilation on the Barrett universal II (new generation), Haigis (4th generation), and SRK/T (3rd generation) intraocular lens calculation formulas: a retrospective study.

Authors:  Takeshi Teshigawara; Akira Meguro; Nobuhisa Mizuki
Journal:  BMC Ophthalmol       Date:  2020-07-20       Impact factor: 2.209

6.  Visual Performance after a Unilateral or Bilateral Implantation of Enlarged Depth-of-Focus Intraocular Lens in Patients with Cataract: A Prospective Clinical Trial.

Authors:  Se Hyun Choi; Hyo Kyung Lee; Chang Ho Yoon; Mee Kum Kim
Journal:  J Ophthalmol       Date:  2019-03-04       Impact factor: 1.909

7.  Accuracy of intraocular lens power calculation formulas using a swept-source optical biometer.

Authors:  Se Young Kim; Seung Hyun Lee; Na Rae Kim; Hee Seung Chin; Ji Won Jung
Journal:  PLoS One       Date:  2020-01-14       Impact factor: 3.240

8.  Evaluation of Barrett universal II formula for intraocular lens power calculation in Asian Indian population.

Authors:  Nikhil Kuthirummal; Murugesan Vanathi; Ritika Mukhija; Noopur Gupta; Rachna Meel; Rohit Saxena; Radhika Tandon
Journal:  Indian J Ophthalmol       Date:  2020-01       Impact factor: 1.848

9.  Accuracy of Intraocular Lens Power Formulas Involving 148 Eyes with Long Axial Lengths: A Retrospective Chart-Review Study.

Authors:  Chong Chen; Xian Xu; Yuyu Miao; Gaoxin Zheng; Yong Sun; Xun Xu
Journal:  J Ophthalmol       Date:  2015-12-17       Impact factor: 1.909

10.  Accuracy of Intraocular Lens Power Calculation Using Anterior Chamber Depth from Two Devices with Barrett Universal II Formula.

Authors:  Hannah Muniz Castro; Audrey X Tai; Samuel J Sampson; Matthew Wade; Marjan Farid; Sumit Garg
Journal:  J Ophthalmol       Date:  2019-09-23       Impact factor: 1.909

View more