Literature DB >> 32953575

Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens.

Jing Zhao1, Liang-Ping Liu1, Huan-Huan Cheng1, Jian-Bing Li1, Xiao-Tong Han1, Yu Liu1, Ming-Xing Wu1.   

Abstract

AIM: To evaluate the accuracy of eight different intraocular lens (IOL) power calculation formulas for a segmented multifocal IOL.
METHODS: A total of 53 eyes of 41 adult cataract patients who underwent phacoemulsification and implantation with the SBL-3 segmented multifocal IOL between January 1, 2017 and January 31, 2019 were included in this retrospective study. Preoperative biometry measurements were obtained using an IOL Master. Manifest refraction was performed at least 4wk postoperatively. Accuracy of the eight formulas [Barrett Universal II, Emmetropia Verifying Optical (EVO), Haigis, Hill-RBF 2.0, Hoffer Q, Holladay 1, Kane, and SRK/T] was analyzed.
RESULTS: Using current lens constants, all formulas exhibited errors of slight myopic shift in refractive prediction. The Barrett Universal II formula had a significantly lower median absolute error (MedAE) than did Holladay 1 (P=0.02), Kane (P=0.001) and Hill-RBF 2.0 (P<0.001) formulas. The Haigis formula had a lower MedAE value than did the Hill-RBF 2.0 formula (P=0.005). Differences in MedAE values among SRK/T, EVO and Hoffer Q formulas were not significant. After optimizing lens constants, the MedAE values of all formulas were reduced; significant changes were noted for EVO (P=0.022), Haigis (P=0.048), Hill-RBF 2.0 (P=0.014), Holladay 1 (P=0.045) and Kane (P=0.022) formulas. All formulas performed equally well after optimization of lens constants (P=0.203).
CONCLUSION: All eight formulas tend to result in a myopic shift when using current lens constants. Optimized lens constants improve the accuracy of these formulas among adult Chinese patients. International Journal of Ophthalmology Press.

Entities:  

Keywords:  accuracy; intraocular lens formulas; lens constants; segmented multifocal intraocular lens

Year:  2020        PMID: 32953575      PMCID: PMC7459228          DOI: 10.18240/ijo.2020.09.07

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  28 in total

1.  IOLMaster biometry: refractive results of 100 consecutive cases.

Authors:  H Eleftheriadis
Journal:  Br J Ophthalmol       Date:  2003-08       Impact factor: 4.638

2.  Accuracy of intraocular lens power calculations in eyes with axial length <22.00 mm.

Authors:  Alexander C Day; Paul J Foster; Julian D Stevens
Journal:  Clin Exp Ophthalmol       Date:  2012-07-11       Impact factor: 4.207

3.  Sources of error in intraocular lens power calculation.

Authors:  Sverker Norrby
Journal:  J Cataract Refract Surg       Date:  2008-03       Impact factor: 3.351

4.  Benchmark standards for refractive outcomes after NHS cataract surgery.

Authors:  R P Gale; M Saldana; R L Johnston; B Zuberbuhler; M McKibbin
Journal:  Eye (Lond)       Date:  2007-08-24       Impact factor: 3.775

5.  Accuracy of Intraocular Lens Calculation Formulas.

Authors:  Ronald B Melles; Jack T Holladay; William J Chang
Journal:  Ophthalmology       Date:  2017-09-23       Impact factor: 12.079

6.  Update on Intraocular Lens Calculation Formulas.

Authors:  Ronald B Melles; Jack X Kane; Thomas Olsen; William J Chang
Journal:  Ophthalmology       Date:  2019-04-11       Impact factor: 12.079

7.  Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses.

Authors:  Richard N McNeely; Eric Pazo; Andrew Spence; Olivier Richoz; M Andrew Nesbit; Tara C B Moore; Jonathan E Moore
Journal:  J Cataract Refract Surg       Date:  2017-08       Impact factor: 3.351

8.  Initial experience with a new refractive rotationally asymmetric multifocal intraocular lens.

Authors:  Jan A Venter; Dean Barclay; Martina Pelouskova; Claire E L Bull
Journal:  J Refract Surg       Date:  2014-11       Impact factor: 3.573

9.  Comparison of the Kane formula with existing formulas for intraocular lens power selection.

Authors:  Benjamin J Connell; Jack X Kane
Journal:  BMJ Open Ophthalmol       Date:  2019-04-01

10.  Four-year analysis of cataract surgery rates in Shanghai, China: a retrospective cross-sectional study.

Authors:  Mingming Zhu; Jianfeng Zhu; Lina Lu; Xiangui He; Rong Zhao; Haidong Zou
Journal:  BMC Ophthalmol       Date:  2014-01-10       Impact factor: 2.209

View more
  1 in total

1.  Comparison of accuracy of intraocular lens power calculation for eyes with an axial length greater than 29.0 mm.

Authors:  Chengyao Guo; Shengjie Yin; Kunliang Qiu; Mingzhi Zhang
Journal:  Int Ophthalmol       Date:  2022-05-10       Impact factor: 2.029

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.