Literature DB >> 25450010

Improved alignment and operating room efficiency with patient-specific instrumentation for TKA.

Luc Renson1, Pascal Poilvache2, Hans Van den Wyngaert3.   

Abstract

BACKGROUND: Achieving accurate alignment in total knee arthroplasty (TKA) remains a concern. Patient-specific instrumentation (PSI) produced using preoperative 3D models was developed to offer surgeons a simplified, reliable, efficient and customised TKA procedure.
METHODS: In this prospective study, 60 patients underwent TKA with conventional instrumentation and 71 patients were operated on using PSI. The primary endpoint was surgical time. Secondary endpoints included operating room (OR) time, the number of instrument trays used and postoperative radiographic limb alignment.
RESULTS: Compared to conventional instrumentation, PSI significantly reduced total surgical time by 8.9 ± 3.3 min (p=0.038), OR time by 8.6 ± 4.2 min (p=0.043), and the number of instrument trays by six trays (p<0.001). Mechanical axis malalignment of the lower limb of >3° was observed in 13% of PSI patients versus 29% with conventional instrumentation (p=0.043). PSI predicted the size of the femoral and tibial components actually used in 85.9% and 78.9% of cases, respectively.
CONCLUSION: PSI improves alignment, surgical and OR time, reduces the number of instruments trays used compared to conventional instrumentation in patients undergoing TKA and results in fewer outliers in overall mechanical alignment in the coronal plane. LEVEL OF EVIDENCE II: Prospective comparative therapeutic study.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Alignment; Patient-matched instrumentation; Patient-specific guides; Patient-specific instruments; Total knee arthroplasty

Mesh:

Year:  2014        PMID: 25450010     DOI: 10.1016/j.knee.2014.09.008

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  19 in total

1.  [Total knee arthroplasty with 3D printing technique versus conventional surgery: comparison of the outcomes].

Authors:  Ming Niu; Fei Ma; Ju-Rong Ma; Jun-Wei Li; Xu-Nian Wu; Tong Wang; Yu-Liang Wang
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-11-20

2.  Patient-specific instrumentation in Oxford unicompartmental knee arthroplasty is reliable and accurate except for the tibial rotation.

Authors:  B Kerens; A M Leenders; M G M Schotanus; B Boonen; W E Tuinebreijer; P J Emans; B Jong; N P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-12-27       Impact factor: 4.342

3.  Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation.

Authors:  Soheil Mehdipour; Mohamad Qoreishi; Ali Keipourfard
Journal:  Arch Bone Jt Surg       Date:  2020-09

4.  Medical 3D Printing Cost-Savings in Orthopedic and Maxillofacial Surgery: Cost Analysis of Operating Room Time Saved with 3D Printed Anatomic Models and Surgical Guides.

Authors:  David H Ballard; Patrick Mills; Richard Duszak; Jeffery A Weisman; Frank J Rybicki; Pamela K Woodard
Journal:  Acad Radiol       Date:  2019-09-18       Impact factor: 3.173

5.  Computerized tomography based "patient specific blocks" improve postoperative mechanical alignment in primary total knee arthroplasty.

Authors:  Raju Vaishya; Vipul Vijay; Vikas P Birla; Amit K Agarwal
Journal:  World J Orthop       Date:  2016-07-18

6.  Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation.

Authors:  Meng Zhu; Jerry Yongqiang Chen; Hwei Chi Chong; Andy Khye Soon Yew; Leon Siang Shen Foo; Shi-Lu Chia; Ngai Nung Lo; Seng Jin Yeo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-26       Impact factor: 4.342

7.  [Total and unicompartmental knee replacement. Patient-specific Instrumentation].

Authors:  G Köster; C Biró
Journal:  Orthopade       Date:  2016-04       Impact factor: 1.087

Review 8.  3D-printing techniques in a medical setting: a systematic literature review.

Authors:  Philip Tack; Jan Victor; Paul Gemmel; Lieven Annemans
Journal:  Biomed Eng Online       Date:  2016-10-21       Impact factor: 2.819

9.  The Effect of Patient-Specific Instrumentation Incorporating an Extramedullary Tibial Guide on Operative Efficiency for Total Knee Arthroplasty.

Authors:  Oh-Ryong Kwon; Kyoung-Tak Kang; Juhyun Son; Dong-Suk Suh; Dong Beom Heo; Yong-Gon Koh
Journal:  Biomed Res Int       Date:  2017-08-03       Impact factor: 3.411

Review 10.  Improving outcomes in total knee arthroplasty-do navigation or customized implants have a role?

Authors:  Matthew D Beal; Dimitri Delagramaticas; David Fitz
Journal:  J Orthop Surg Res       Date:  2016-05-23       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.