Literature DB >> 25383976

Modulation indices for volumetric modulated arc therapy.

Jong Min Park1, So-Yeon Park, Hyoungnyoun Kim, Jin Ho Kim, Joel Carlson, Sung-Joon Ye.   

Abstract

The aim of this study is to present a modulation index (MI) for volumetric modulated arc therapy (VMAT) based on the speed and acceleration analysis of modulating-parameters such as multi-leaf collimator (MLC) movements, gantry rotation and dose-rate, comprehensively. The performance of the presented MI (MIt) was evaluated with correlation analyses to the pre-treatment quality assurance (QA) results, differences in modulating-parameters between VMAT plans versus dynamic log files, and differences in dose-volumetric parameters between VMAT plans versus reconstructed plans using dynamic log files. For comparison, the same correlation analyses were performed for the previously suggested modulation complexity score (MCS(v)), leaf travel modulation complexity score (LTMCS) and MI by Li and Xing (MI Li&Xing). In the two-tailed unpaired parameter condition, p values were acquired. The Spearman's rho (r(s)) values of MIt, MCSv, LTMCS and MI Li&Xing to the local gamma passing rate with 2%/2 mm criterion were -0.658 (p < 0.001), 0.186 (p = 0.251), 0.312 (p = 0.05) and -0.455 (p = 0.003), respectively. The values of rs to the modulating-parameter (MLC positions) differences were 0.917, -0.635, -0.857 and 0.795, respectively (p < 0.001). For dose-volumetric parameters, MIt showed higher statistically significant correlations than the conventional MIs. The MIt showed good performance for the evaluation of the modulation-degree of VMAT plans.

Entities:  

Mesh:

Year:  2014        PMID: 25383976     DOI: 10.1088/0031-9155/59/23/7315

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  23 in total

1.  The effect of MLC speed and acceleration on the plan delivery accuracy of VMAT.

Authors:  J M Park; H-G Wu; J H Kim; J N K Carlson; K Kim
Journal:  Br J Radiol       Date:  2015-03-03       Impact factor: 3.039

Review 2.  Complexity metrics for IMRT and VMAT plans: a review of current literature and applications.

Authors:  Sophie Chiavassa; Igor Bessieres; Magali Edouard; Michel Mathot; Alexandra Moignier
Journal:  Br J Radiol       Date:  2019-07-24       Impact factor: 3.039

3.  Treatment plan complexity does not predict IROC Houston anthropomorphic head and neck phantom performance.

Authors:  Mallory C Glenn; Victor Hernandez; Jordi Saez; David S Followill; Rebecca M Howell; Julianne M Pollard-Larkin; Shouhao Zhou; Stephen F Kry
Journal:  Phys Med Biol       Date:  2018-10-17       Impact factor: 3.609

4.  The role of complexity metrics in a multi-institutional dosimetry audit of VMAT.

Authors:  Conor K McGarry; Christina E Agnew; Mohammad Hussein; Yatman Tsang; Alan McWilliam; Alan R Hounsell; Catharine H Clark
Journal:  Br J Radiol       Date:  2015-10-29       Impact factor: 3.039

5.  Predicting gamma evaluation results of patient-specific head and neck volumetric-modulated arc therapy quality assurance based on multileaf collimator patterns and fluence map features: A feasibility study.

Authors:  Sangutid Thongsawad; Somyot Srisatit; Todsaporn Fuangrod
Journal:  J Appl Clin Med Phys       Date:  2022-05-18       Impact factor: 2.243

6.  Dosimetric comparison of dynamic conformal arc integrated with segment shape optimization and variable dose rate versus volumetric modulated arc therapy for liver SBRT.

Authors:  Deepak Thaper; Rose Kamal; Gaganpreet Singh; Arun S Oinam; Hanuman P Yadav; Rishabh Kumar; Vivek Kumar
Journal:  Rep Pract Oncol Radiother       Date:  2020-05-20

7.  Impact of different optimization strategies on the compatibility between planned and delivered doses during radiation therapy of cervical cancer.

Authors:  Agata Jodda; Tomasz Piotrowski; Marta Kruszyna-Mochalska; Julian Malicki
Journal:  Rep Pract Oncol Radiother       Date:  2020-04-12

8.  Texture analysis on the edge-enhanced fluence of VMAT.

Authors:  So-Yeon Park; Jong Min Park; Wonmo Sung; Il Han Kim; Sung-Joon Ye
Journal:  Radiat Oncol       Date:  2015-04-01       Impact factor: 3.481

9.  The effect of extremely narrow MLC leaf width on the plan quality of VMAT for prostate cancer.

Authors:  Jong Min Park; So-Yeon Park; Jin Ho Kim; Joel Carlson; Jung-In Kim
Journal:  Radiat Oncol       Date:  2016-06-23       Impact factor: 3.481

10.  Correlation analysis between 2D and quasi-3D gamma evaluations for both intensity-modulated radiation therapy and volumetric modulated arc therapy.

Authors:  Jung-In Kim; Chang Heon Choi; Hong-Gyun Wu; Jin Ho Kim; Kyubo Kim; Jong Min Park
Journal:  Oncotarget       Date:  2017-01-17
View more