Literature DB >> 25381403

Large diameter femoral heads: is bigger always better?

H J Cooper1, C J Della Valle2.   

Abstract

Dislocation remains among the most common complications of, and reasons for, revision of both primary and revision total hip replacements (THR). Hence, there is great interest in maximising stability to prevent this complication. Head size has been recognised to have a strong influence on the risk of dislocation post-operatively. As femoral head size increases, stability is augmented, secondary to an increase in impingement-free range of movement. Larger head sizes also greatly increase the 'jump distance' required for the head to dislocate in an appropriately positioned cup. Level-one studies support the use of larger diameter heads as they decrease the risk of dislocation following primary and revision THR. Highly cross-linked polyethylene has allowed us to increase femoral head size, without a marked increase in wear. However, the thin polyethylene liners necessary to accommodate larger heads may increase the risk of liner fracture and larger heads have also been implicated in causing soft-tissue impingement resulting in groin pain. Larger diameter heads also impart larger forces on the femoral trunnion, which may contribute to corrosion, metal release, and adverse local tissue reactions. Alternative large bearings including large ceramic heads and dual mobility bearings may mitigate some of these risks, and several of these devices have been used with clinical success. ©2014 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Instability; Large femoral head; Taper corrosion; Total hip replacement

Mesh:

Year:  2014        PMID: 25381403     DOI: 10.1302/0301-620X.96B11.34342

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  30 in total

1.  Low Frequency of Early Complications With Dual-mobility Acetabular Cups in Cementless Primary THA.

Authors:  Morad Chughtai; Jaydev B Mistry; Aloise M Diedrich; Julio J Jauregui; Randa K Elmallah; Peter M Bonutti; Steven F Harwin; Arthur L Malkani; Frank R Kolisek; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

Review 2.  [Hip dislocation after revision arthroplasty : Risk assessment and treatment strategies].

Authors:  P M Prodinger; J Schauwecker; H Mühlhofer; N Harrasser; F Pohlig; C Suren; R von Eisenhart-Rothe
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

Review 3.  Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options.

Authors:  Luigi Zagra; Eleonora Caboni
Journal:  Int Orthop       Date:  2017-01-14       Impact factor: 3.075

4.  No Increase in Survival for 36-mm versus 32-mm Femoral Heads in Metal-on-polyethylene THA: A Registry Study.

Authors:  Georgios Tsikandylakis; Johan Kärrholm; Nils P Hailer; Antti Eskelinen; Keijo T Mäkelä; Geir Hallan; Ove Nord Furnes; Alma B Pedersen; Søren Overgaard; Maziar Mohaddes
Journal:  Clin Orthop Relat Res       Date:  2018-12       Impact factor: 4.176

5.  CORR Insights(®): Modular to Monoblock: Difficulties of Detaching the M(2)a-Magnum(™) Head Are Common in Metal-on-metal Revisions.

Authors:  Rodrigo M Mardones
Journal:  Clin Orthop Relat Res       Date:  2016-05-18       Impact factor: 4.176

6.  Primary total hip replacement in Ficat-Arlet stage 3 and 4 osteonecrosis: a retrospective study at a minimum 12-year follow-up.

Authors:  Roger Erivan; Thomas Caputo; Hicham Riouach; Guillaume Villatte; Bruno Perreira; Stéphane Descamps; Stéphane Boisgard
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-02-27

7.  Comparison of metal ion levels in patients with hip resurfacing versus total hip arthroplasty.

Authors:  Craig W Forsthoefel; Nicholas M Brown; Mark L Barba
Journal:  J Orthop       Date:  2017-08-31

8.  Dual mobility cups provide biomechanical advantages in situations at risk for dislocation: a finite element analysis.

Authors:  Alexandre Terrier; Adeliya Latypova; Maika Guillemin; Valérie Parvex; Olivier Guyen
Journal:  Int Orthop       Date:  2017-01-09       Impact factor: 3.075

9.  The focally constrained liner is a reasonable option for revision of unstable total hip arthroplasty.

Authors:  Tatu J Mäkinen; Simcha G Fichman; Wael A Rahman; Tomas Amenabar; Oleg Safir; Allan E Gross; Paul R T Kuzyk
Journal:  Int Orthop       Date:  2015-12-23       Impact factor: 3.075

10.  The efficacy of dual-mobility cup in preventing dislocation after total hip arthroplasty: a systematic review and meta-analysis of comparative studies.

Authors:  Matteo Romagnoli; Alberto Grassi; Giuseppe Gianluca Costa; Lionel E Lazaro; Mirco Lo Presti; Stefano Zaffagnini
Journal:  Int Orthop       Date:  2018-07-21       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.