Literature DB >> 25381092

Stress thallium-201/rest technetium-99m sequential dual-isotope high-speed myocardial perfusion imaging validation versus invasive coronary angiography.

Gilles Barone-Rochette1, Mélanie Leclere, Alex Calizzano, Estelle Vautrin, Gallazzini-Crepin Céline, Alexis Broisat, Catherine Ghezzi, Jean Philippe Baguet, Jacques Machecourt, Gérald Vanzetto, Daniel Fagret.   

Abstract

BACKGROUND: Recent advances in nuclear myocardial perfusion imaging (MPI) have made it possible to develop a dual-isotope protocol for high-speed acquisition with image quality and radiation delivery comparable to that obtained with conventional single isotope protocols. So far, no study has compared dual-isotope high-speed MPI to invasive coronary angiography (ICA) in a large cohort using a Cadmium-zinc-telluride SPECT system.
METHODS: Over a 1-year period (May 2011 to April 2012), 1366 patients underwent dual-isotope high-speed MPI. Patients with ICA within 3 months after dual-isotope high-speed MPI were included together with patients with a low likelihood of coronary artery disease (CAD) in order to assess normalcy rate. Global summed stress score (SSS) and summed rest score (SRS) were calculated, and ICA results were analyzed independently. The main end point was a patient-based assessment of the diagnostic performance of dual-isotope high-speed MPI in detecting or ruling out significant CAD (>70% reduction in lumen diameter).
RESULTS: Inclusion criteria were fulfilled for 214 patients (143 men; age 60 ± 14 years; ICA, n = 104; low likelihood for CAD, n = 110). An exercise stress test was performed in 62% of patients and a pharmacological stress test was performed with either dipyridamole (32%) or dobutamine (6%). Average examination duration was 22.4 ± 4.5 minutes. Mean SSS, SRS, and SDS were 8.0 ± 4.9, 3.1 ± 4.3, and 5.0 ± 3.2, respectively. Prevalence of angiographic CAD was 75%. ICA detected stenosis in the left main trunk, left anterior descending artery, left circumflex artery, and right coronary artery in 4, 33, 31, and 42 patients, respectively. Sensitivity of dual-isotope high-speed MPI was 94%, normalcy rate was 92%, and accuracy was 83% for detecting CAD.
CONCLUSION: Dual-isotope high-speed MPI is reliable at detecting or ruling out CAD. NCT01785589.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25381092     DOI: 10.1007/s12350-014-0016-0

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  29 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Warren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Circulation       Date:  2002-01-29       Impact factor: 29.690

2.  Comparison of high efficiency CZT SPECT MPI to coronary angiography.

Authors:  W Lane Duvall; Joseph M Sweeny; Lori B Croft; Maya H Barghash; Nitin K Kulkarni; Krista A Guma; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2011-06-03       Impact factor: 5.952

3.  Comparison of simultaneous dual-isotope multipinhole SPECT with rotational SPECT in a group of patients with coronary artery disease.

Authors:  Peter P Steele; Dennis L Kirch; John E Koss
Journal:  J Nucl Med       Date:  2008-06-13       Impact factor: 10.057

4.  High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: preliminary clinical results.

Authors:  Alessia Gimelli; Matteo Bottai; Dario Genovesi; Assuero Giorgetti; Fabio Di Martino; Paolo Marzullo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-09-02       Impact factor: 9.236

5.  Pharmacokinetics of thallium-201 in normal individuals after routine myocardial scintigraphy.

Authors:  W Krahwinkel; H Herzog; L E Feinendegen
Journal:  J Nucl Med       Date:  1988-09       Impact factor: 10.057

6.  Angiographic versus functional severity of coronary artery stenoses in the FAME study fractional flow reserve versus angiography in multivessel evaluation.

Authors:  Pim A L Tonino; William F Fearon; Bernard De Bruyne; Keith G Oldroyd; Massoud A Leesar; Peter N Ver Lee; Philip A Maccarthy; Marcel Van't Veer; Nico H J Pijls
Journal:  J Am Coll Cardiol       Date:  2010-06-22       Impact factor: 24.094

7.  Nuclear myocardial perfusion imaging with a novel cadmium-zinc-telluride detector SPECT/CT device: first validation versus invasive coronary angiography.

Authors:  Michael Fiechter; Jelena R Ghadri; Silke M Kuest; Aju P Pazhenkottil; Mathias Wolfrum; Rene N Nkoulou; Robert Goetti; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-07-15       Impact factor: 9.236

8.  Quantitative upright-supine high-speed SPECT myocardial perfusion imaging for detection of coronary artery disease: correlation with invasive coronary angiography.

Authors:  Ryo Nakazato; Balaji K Tamarappoo; Xingping Kang; Arik Wolak; Faith Kite; Sean W Hayes; Louise E J Thomson; John D Friedman; Daniel S Berman; Piotr J Slomka
Journal:  J Nucl Med       Date:  2010-10-18       Impact factor: 10.057

9.  Initial multicentre experience of high-speed myocardial perfusion imaging: comparison between high-speed and conventional single-photon emission computed tomography with angiographic validation.

Authors:  Johanne Neill; Elizabeth M Prvulovich; Matthews B Fish; Daniel S Berman; Piotr J Slomka; Tali Sharir; William H Martin; Marcelo F DiCarli; Jack A Ziffer; Jamshed B Bomanji; Dalia Shiti; Simona Ben-Haim
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-04-18       Impact factor: 9.236

Review 10.  Myocardial perfusion scintigraphy: the evidence.

Authors:  S R Underwood; C Anagnostopoulos; M Cerqueira; P J Ell; E J Flint; M Harbinson; A D Kelion; A Al-Mohammad; E M Prvulovich; L J Shaw; A C Tweddel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02       Impact factor: 9.236

View more
  7 in total

1.  Return of dual-isotope SPECT myocardial perfusion imaging? Not so fast….

Authors:  Milena J Henzlova; W Lane Duvall
Journal:  J Nucl Cardiol       Date:  2015-06       Impact factor: 5.952

2.  Prospective diagnostic performance of semiconductor SPECT myocardial perfusion imaging: wall thickening analysis reduces the need for an additional prone acquisition.

Authors:  Loïc Djaileb; Benjamin Dubois; Nicolas de Leiris; Julien Leenhardt; Marjorie Canu; Olivier Phan Sy; Adrien Carabelli; Bastien Boussat; Laurent Dumas; Alexis Broisat; Gérald Vanzetto; Daniel Fagret; Catherine Ghezzi; Gilles Barone-Rochette; Laurent M Riou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-07-18       Impact factor: 9.236

3.  Diagnostic implications of CZT SPECT and impact of CT attenuation correction.

Authors:  Andrew Peters; Jeevan Kumar; Pravin V Patil
Journal:  J Nucl Cardiol       Date:  2017-06-23       Impact factor: 5.952

4.  SPECT myocardial ischemia in the absence of obstructive CAD: Contribution of the invasive assessment of microvascular dysfunction.

Authors:  Loïc Djaïleb; Laurent Riou; Nicolas Piliero; Adrien Carabelli; Estelle Vautrin; Alexis Broisat; Julien Leenhardt; Jacques Machecourt; Daniel Fagret; Gerald Vanzetto; Gilles Barone-Rochette; Catherine Ghezzi
Journal:  J Nucl Cardiol       Date:  2017-12-05       Impact factor: 5.952

Review 5.  Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM).

Authors:  Denis Agostini; Pierre-Yves Marie; Simona Ben-Haim; François Rouzet; Bernard Songy; Alessandro Giordano; Alessia Gimelli; Fabien Hyafil; Roberto Sciagrà; Jan Bucerius; Hein J Verberne; Riemer H J A Slart; Oliver Lindner; Christopher Übleis; Marcus Hacker
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-08-19       Impact factor: 9.236

6.  Diagnostic value of stress thallium-201/rest technetium-99m-sestamibi sequential dual isotope high-speed myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis.

Authors:  Gilles Barone-Rochette; Feras Zoreka; Loïc Djaileb; Nicolas Piliero; Alex Calizzano; Jean Louis Quesada; Alexis Broisat; Laurent Riou; Jacques Machecourt; Daniel Fagret; Gerald Vanzetto; Catherine Ghezzi
Journal:  J Nucl Cardiol       Date:  2018-01-29       Impact factor: 5.952

7.  Diagnostic performance of myocardial perfusion imaging with conventional and CZT single-photon emission computed tomography in detecting coronary artery disease: A meta-analysis.

Authors:  Valeria Cantoni; Roberta Green; Wanda Acampa; Emilia Zampella; Roberta Assante; Carmela Nappi; Valeria Gaudieri; Teresa Mannarino; Renato Cuocolo; Eugenio Di Vaia; Mario Petretta; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2019-05-14       Impact factor: 5.952

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.