Literature DB >> 25376031

In vivo and in vitro comparison of the charge injection capacity of platinum macroelectrodes.

Ronald T Leung, Mohit N Shivdasani, David A X Nayagam, Robert K Shepherd.   

Abstract

Platinum (Pt) is the most commonly used metal for stimulating electrodes. This study aims to determine the amount of charge that can be delivered without causing irreversible electrochemical reactions (charge injection capacity, Q inj) of Pt macroelectrodes (geometric surface area >0.001 cm(2)) in vitro and in vivo using voltage transient measurements. Pt macroelectrodes were stimulated with biphasic charge-balanced cathodic-first constant-current pulses in phosphate buffered saline. Potential excursions were measured (versus Ag/AgCl electrode) and used to determine Qinj. The in vitro Qinj were compared to those measured in vivo following: acute and chronic implantation close to the retina; chronic intracochlear implantation; and acute subdural implantation, in the cat. Qinj increased with pulsewidth from 35 to 54 μC/cm(2) for respective pulse widths of 100 to 3200 μs per phase in vitro. Qinj was significantly less in vivo. There was no significant difference in Qinj between acutely (3.84 to 16.6 μC/cm(2) with pulsewidths of 100 to 3200 μs) and chronically (6.99 to 15.8 μC/cm(2) with pulsewidths of 200 to 3200 μs) implanted suprachoroidal electrodes. Intracochlear Qinj was not different to suprachoroidal Qinj, while subdural Qinj was significantly less than the suprachoroidal Q inj (p < 0.05). These results have important implications in providing guidelines on Qinj for the safe use of Pt stimulating macroelectrodes and question the relevance of measuring Qinj in vivo using voltage transients.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25376031     DOI: 10.1109/TBME.2014.2366514

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  16 in total

1.  Are long stimulus pulse durations the answer to improving spatial resolution in retinal prostheses?

Authors:  Matthew A Petoe; Mohit N Shivdasani
Journal:  Ann Transl Med       Date:  2016-11

2.  Integrated, Transparent Silicon Carbide Electronics and Sensors for Radio Frequency Biomedical Therapy.

Authors:  Tuan-Khoa Nguyen; Sharda Yadav; Thanh-An Truong; Mengdi Han; Matthew Barton; Michael Leitch; Pablo Guzman; Toan Dinh; Aditya Ashok; Hieu Vu; Van Dau; Daniel Haasmann; Lin Chen; Yoonseok Park; Thanh Nho Do; Yusuke Yamauchi; John A Rogers; Nam-Trung Nguyen; Hoang-Phuong Phan
Journal:  ACS Nano       Date:  2022-07-11       Impact factor: 18.027

3.  Implications of Neural Plasticity in Retinal Prosthesis.

Authors:  Daniel Caravaca-Rodriguez; Susana P Gaytan; Gregg J Suaning; Alejandro Barriga-Rivera
Journal:  Invest Ophthalmol Vis Sci       Date:  2022-10-03       Impact factor: 4.925

4.  The development of neural stimulators: a review of preclinical safety and efficacy studies.

Authors:  Robert K Shepherd; Joel Villalobos; Owen Burns; David A X Nayagam
Journal:  J Neural Eng       Date:  2018-05-14       Impact factor: 5.379

Review 5.  Tissue damage thresholds during therapeutic electrical stimulation.

Authors:  Stuart F Cogan; Kip A Ludwig; Cristin G Welle; Pavel Takmakov
Journal:  J Neural Eng       Date:  2016-01-20       Impact factor: 5.379

6.  Electrochemical characteristics of ultramicro-dimensioned SIROF electrodes for neural stimulation and recording.

Authors:  A Ghazavi; J Maeng; M Black; S Salvi; S F Cogan
Journal:  J Neural Eng       Date:  2020-01-06       Impact factor: 5.379

7.  An evaluation framework for research platforms to advance cochlear implant/hearing aid technology: A case study with CCi-MOBILE.

Authors:  Ram C M C Shekar; John H L Hansen
Journal:  J Acoust Soc Am       Date:  2021-01       Impact factor: 1.840

8.  Platinum dissolution and tissue response following long-term electrical stimulation at high charge densities.

Authors:  Robert K Shepherd; Paul M Carter; Ashley N Dalrymple; Ya Lang Enke; Andrew K Wise; Trung Nguyen; James Firth; Alex Thompson; James B Fallon
Journal:  J Neural Eng       Date:  2021-03-17       Impact factor: 5.379

9.  Closed-loop neuromodulation will increase the utility of mouse models in Bioelectronic Medicine.

Authors:  Timir Datta-Chaudhuri
Journal:  Bioelectron Med       Date:  2021-06-30

Review 10.  Electrode Materials for Chronic Electrical Microstimulation.

Authors:  Xin Sally Zheng; Chao Tan; Elisa Castagnola; Xinyan Tracy Cui
Journal:  Adv Healthc Mater       Date:  2021-05-24       Impact factor: 11.092

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.