Literature DB >> 25375634

Low coherence interferometry approach for aiding fine needle aspiration biopsies.

Ernest W Chang1, Joseph Gardecki2, Martha Pitman3, Eric J Wilsterman2, Ankit Patel1, Guillermo J Tearney2, Nicusor Iftimia1.   

Abstract

We present portable preclinical low-coherence interference (LCI) instrumentation for aiding fine needle aspiration biopsies featuring the second-generation LCI-based biopsy probe and an improved scoring algorithm for tissue differentiation. Our instrument and algorithm were tested on 38 mice with cultured tumor mass and we show the specificity, sensitivity, and positive predictive value of tumor detection of over 0.89, 0.88, and 0.96, respectively.

Entities:  

Mesh:

Year:  2014        PMID: 25375634      PMCID: PMC4222708          DOI: 10.1117/1.JBO.19.11.116005

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  22 in total

1.  Diagnostic accuracy of fine-needle aspiration biopsy is determined by physician training in sampling technique.

Authors:  B M Ljung; A Drejet; N Chiampi; J Jeffrey; W H Goodson; K Chew; D H Moore; T R Miller
Journal:  Cancer       Date:  2001-08-25       Impact factor: 6.860

2.  Fine-needle aspiration biopsy of nonpalpable breast lesions in a multicenter clinical trial: results from the radiologic diagnostic oncology group V.

Authors:  E D Pisano; L L Fajardo; D J Caudry; N Sneige; W J Frable; W A Berg; I Tocino; S J Schnitt; J L Connolly; C A Gatsonis; B J McNeil
Journal:  Radiology       Date:  2001-06       Impact factor: 11.105

3.  Texture analysis of optical coherence tomography images: feasibility for tissue classification.

Authors:  Kirk W Gossage; Tomasz S Tkaczyk; Jeffrey J Rodriguez; Jennifer K Barton
Journal:  J Biomed Opt       Date:  2003-07       Impact factor: 3.170

4.  Comparing the areas under two correlated ROC curves: parametric and non-parametric approaches.

Authors:  Katy Molodianovitch; David Faraggi; Benjamin Reiser
Journal:  Biom J       Date:  2006-08       Impact factor: 2.207

5.  Specimen adequacy and false-negative diagnosis rate in fine-needle aspirates of palpable breast masses.

Authors:  S Boerner; N Sneige
Journal:  Cancer       Date:  1998-12-25       Impact factor: 6.860

6.  Accuracy of cytologic diagnoses made from touch imprints of image-guided needle biopsy specimens of nonpalpable breast abnormalities.

Authors:  N Sneige; A Tulbah
Journal:  Diagn Cytopathol       Date:  2000-07       Impact factor: 1.582

7.  Use of fine needle aspiration for solid breast lesions is accurate and cost-effective.

Authors:  M Rubin; K Horiuchi; N Joy; W Haun; R Read; E Ratzer; M Fenoglio
Journal:  Am J Surg       Date:  1997-12       Impact factor: 2.565

8.  Ultrasound-guided, vacuum-assisted, percutaneous excision of breast lesions: an accurate technique in the diagnosis of atypical ductal hyperplasia.

Authors:  Ian Grady; Heidi Gorsuch; Shelly Wilburn-Bailey
Journal:  J Am Coll Surg       Date:  2005-07       Impact factor: 6.113

9.  Stereotactic fine-needle biopsy in 2594 mammographically detected non-palpable lesions.

Authors:  E Azavedo; G Svane; G Auer
Journal:  Lancet       Date:  1989-05-13       Impact factor: 79.321

Review 10.  Biopsy confirmation of metastatic sites in breast cancer patients: clinical impact and future perspectives.

Authors:  Carmen Criscitiello; Fabrice André; Alastair M Thompson; Michele De Laurentiis; Angela Esposito; Lucia Gelao; Luca Fumagalli; Marzia Locatelli; Ida Minchella; Franco Orsi; Aron Goldhirsch; Giuseppe Curigliano
Journal:  Breast Cancer Res       Date:  2014       Impact factor: 6.466

View more
  2 in total

1.  Dimension reduction technique using a multilayered descriptor for high-precision classification of ovarian cancer tissue using optical coherence tomography: a feasibility study.

Authors:  Catherine St-Pierre; Wendy-Julie Madore; Etienne De Montigny; Dominique Trudel; Caroline Boudoux; Nicolas Godbout; Anne-Marie Mes-Masson; Kurosh Rahimi; Frédéric Leblond
Journal:  J Med Imaging (Bellingham)       Date:  2017-10-12

2.  Intraoperative detection of blood vessels with an imaging needle during neurosurgery in humans.

Authors:  Hari Ramakonar; Bryden C Quirk; Rodney W Kirk; Jiawen Li; Angela Jacques; Christopher R P Lind; Robert A McLaughlin
Journal:  Sci Adv       Date:  2018-12-19       Impact factor: 14.136

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.