Stereotactic fine-needle biopsy in 2594 mammographically detected non-palpable lesions.

E Azavedo1, G Svane, G Auer.   

Abstract

To assess the accuracy of detection of breast cancers by mammography and stereotactic fine-needle biopsy (SFNB) 2594 mammographically detected non-palpable lesions were sampled. On the basis of combined evaluation by mammography and cytology of these samples, 2005 (77.3%) of the cases were judged as benign lesions without need of surgery and only 1 of these turned out to be a cancer 14 months later. In 567 (21.9%) patients diagnostic and/or therapeutic surgery was done. Breast cancer was confirmed by histopathology in 429 (75.7%) of the patients operated on and a further 60(10.6%) had non-malignant pathological changes (eg, sclerosing adenosis, epitheliosis, fibroadenoma, or papilloma). Thus, surgery was justified in 86.3% (489) of the patients. In addition to the histopathologically verified cancers, another 22 (0.8%) breast cancers were diagnosed by mammography and cytology but these patients were not subjected to surgery for various reasons. A combination of mammography and SFNB offers a procedure of high sensitivity for early diagnosis of breast cancer.

Entities:  

Mesh:

Year:  1989        PMID: 2565996     DOI: 10.1016/s0140-6736(89)92441-0

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  19 in total

1.  Best Practice No 179. Guidelines for breast needle core biopsy handling and reporting in breast screening assessment.

Authors:  I O Ellis; S Humphreys; M Michell; S E Pinder; C A Wells; H D Zakhour
Journal:  J Clin Pathol       Date:  2004-09       Impact factor: 3.411

2.  Immediate reporting of fine needle aspiration of breast lesions.

Authors:  J M Dixon
Journal:  BMJ       Date:  1991-02-23

3.  Automated algorithm for breast tissue differentiation in optical coherence tomography.

Authors:  Mircea Mujat; R Daniel Ferguson; Daniel X Hammer; Christopher Gittins; Nicusor Iftimia
Journal:  J Biomed Opt       Date:  2009 May-Jun       Impact factor: 3.170

4.  Breast cyst aspiration.

Authors:  L Mahoney; R Heisey; B Watson
Journal:  Can Fam Physician       Date:  1998-10       Impact factor: 3.275

Review 5.  General surgery.

Authors:  I Taylor
Journal:  Postgrad Med J       Date:  1990-05       Impact factor: 2.401

6.  Low coherence interferometry approach for aiding fine needle aspiration biopsies.

Authors:  Ernest W Chang; Joseph Gardecki; Martha Pitman; Eric J Wilsterman; Ankit Patel; Guillermo J Tearney; Nicusor Iftimia
Journal:  J Biomed Opt       Date:  2014       Impact factor: 3.170

7.  Stereotactic breast biopsy as an alternative to open excisional biopsy.

Authors:  M J Cross; W P Evans; G N Peters; J H Cheek; R C Jones; P Krakos
Journal:  Ann Surg Oncol       Date:  1995-05       Impact factor: 5.344

Review 8.  Breast cancer: early diagnosis of precursor lesions and clinically inapparent carcinoma by fine needle aspiration.

Authors:  J A Linsk
Journal:  Med Oncol Tumor Pharmacother       Date:  1991

Review 9.  When can stereotactic core biopsy replace excisional biopsy?--A clinical perspective.

Authors:  M Morrow
Journal:  Breast Cancer Res Treat       Date:  1995       Impact factor: 4.872

10.  Clinical feasibility of microscopically-guided breast needle biopsy using a fiber-optic probe with computer-aided detection.

Authors:  Adam M Zysk; Freddy T Nguyen; Eric J Chaney; Jan G Kotynek; Uretz J Oliphant; Frank J Bellafiore; Patricia A Johnson; Kendrith M Rowland; Stephen A Boppart
Journal:  Technol Cancer Res Treat       Date:  2009-10
View more