Literature DB >> 22559846

Utility of VasoCT in the treatment of intracranial aneurysm with flow-diverter stents.

Osman Kizilkilic1, Naci Kocer, George Emmanuel Metaxas, Drazenko Babic, Robert Homan, Civan Islak.   

Abstract

OBJECT: The small size and tortuous anatomy of intracranial arteries require that flow-diverter stents in the intracranial vasculature have a low profile, high flexibility, and excellent trackability. However, these features limit the degree of radiopacity that can be incorporated into the stents. Visualization of these stents and the degree of stent deployment using conventional radiographic techniques is suboptimal. To overcome this drawback, the authors used a new combined angiography/CT suite that uses flat-panel detector technology for higher resolution angiography.
METHODS: The authors present their preliminary experience in the imaging of flow-diverter stents in 31 patients in whom VasoCT was used with a new flat-panel detector angiographic system.
RESULTS: Intraarterial VasoCT was performed after flow-diverter stent deployment in all cases. In 4 of these cases, balloon angioplasty or telescopic stent deployment-related decisions were made after checking VasoCT images. At 3- and 6-month follow-up in 27 patients, digital subtraction angiography was performed in 12 patients and intravenous VasoCT in 11 patients. Twenty-three of 31 patients had their aneurysm occluded during short-term follow-up, and 4 of the 31 patients still had minimal residual filling of the aneurysms. None of the 27 patients had stenosis of the parent artery.
CONCLUSIONS: The authors found that VasoCT provides clear visualization of flow-diverter stents. The images obtained both intraarterially and intravenously are very promising. The initial results provide a high confidence and reproducibility rate for further utilization of this new technique.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22559846     DOI: 10.3171/2012.4.JNS111660

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  12 in total

Review 1.  Flow-diverter devices in the treatment of intracranial aneurysms: A meta-analysis and systematic review.

Authors:  Xianli Lv; Hongchao Yang; Peng Liu; Youxiang Li
Journal:  Neuroradiol J       Date:  2016-02-02

2.  Wall Apposition Is a Key Factor for Aneurysm Occlusion after Flow Diversion: A Histologic Evaluation in 41 Rabbits.

Authors:  A Rouchaud; C Ramana; W Brinjikji; Y-H Ding; D Dai; T Gunderson; J Cebral; D F Kallmes; R Kadirvel
Journal:  AJNR Am J Neuroradiol       Date:  2016-07-07       Impact factor: 3.825

3.  Potential of 80-kV high-resolution cone-beam CT imaging combined with an optimized protocol for neurological surgery.

Authors:  Seisaku Kanayama; Takayuki Hara; Yusuke Hamada; Yuji Matsumaru
Journal:  Neuroradiology       Date:  2014-11-05       Impact factor: 2.804

4.  Filament inadequate wall apposition of the different ends of flow diverters in the abdominal aorta of rabbits.

Authors:  Kuizhong Wang; Peng Jin; Peigang Lu; Qiang Liu; Bo Li; Zhenqiang Hao
Journal:  Neuroradiol J       Date:  2019-11-27

5.  Usefulness of Cone Beam Intra-Arterial CTA for Evaluation of Flow Diverters: A Practical Approach for Daily Use.

Authors:  Dennys Reyes; Victor Becerra; Indiana Alcala; Italo Linfante; Guilherme Dabus
Journal:  Interv Neurol       Date:  2018-07-18

6.  A technical note on intra-arterial cone-beam computed tomography for the evaluation of flow-diverter stents: Image quality differences between diluted and non-diluted contrast medium.

Authors:  Naci Kocer; Sedat G Kandemirli; Daniel Ruijters; Michalis Mantatzis; Osman Kizilkilic; Civan Islak
Journal:  Interv Neuroradiol       Date:  2019-11-25       Impact factor: 1.610

7.  Treatment of an internal carotid artery aneurysm with a flow diverter through a double lumen balloon catheter.

Authors:  José M Amorim; Santiago Rosati; Ronit Agid; Vítor Mendes Pereira; Timo Krings
Journal:  Interv Neuroradiol       Date:  2017-01-01       Impact factor: 1.610

8.  Virtual-versus-Real Implantation of Flow Diverters: Clinical Potential and Influence of Vascular Geometry.

Authors:  P Bouillot; O Brina; H Yilmaz; M Farhat; G Erceg; K-O Lovblad; M I Vargas; Z Kulcsar; V M Pereira
Journal:  AJNR Am J Neuroradiol       Date:  2016-06-30       Impact factor: 3.825

9.  Flow-Diverter Stents for the Treatment of Saccular Middle Cerebral Artery Bifurcation Aneurysms.

Authors:  J Caroff; H Neki; C Mihalea; F D'Argento; H Abdel Khalek; L Ikka; J Moret; L Spelle
Journal:  AJNR Am J Neuroradiol       Date:  2015-09-24       Impact factor: 3.825

10.  Cellular mechanisms of aneurysm occlusion after treatment with a flow diverter.

Authors:  Ramanathan Kadirvel; Yong-Hong Ding; Daying Dai; Issa Rezek; Debra A Lewis; David F Kallmes
Journal:  Radiology       Date:  2013-10-28       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.