Evaluation of Safety, Efficacy, and Expulsion of Post-Placental and Intra-Cesarean Insertion of Intrauterine Contraceptive Devices (PPIUCD).

Sujnanendra Mishra1.   

Abstract

BACKGROUND: This study examines to describe the factors associated with acceptability of immediate PPIUCD insertion in women according to their socio-demographic and obstetrics characteristics, and future pregnancy desires and to determine the rates of uterine perforation, expulsion, pelvic infection, lost strings and displacement following PPIUCD insertion among the acceptors by 6 to 18 months. AIM: An intrauterine device (IUD) is an effective form of Long Acting Reversible Contraception. Present study is aimed at determining the safety, efficacy, and expulsion of Post-placental and intra-cesarean insertion of Intrauterine contraceptive device (PPIUCD). MATERIALS &
METHODS: The study was conducted at District Head Quarters Hospital, Bolangir, Odisha, India. From 1st. January 2012 to 31st. December 2012. Women admitted and delivered at D.H.H. Bolangir, were counseled. CuT 380A was inserted within 10 minutes of delivery of placenta in accepters who fulfilled the Medical Eligibility Criteria and had no contraindications for PPIUCD. They were followed up till 30th June 2013.
RESULTS: Total women counseled 3209, Accepted 564, Declined 2645, lost to follow up 130, Followed up 434, COMPLICATIONS: 190 (Expulsion 39, Bleeding 102, String problem 49), Removal 43, Continuation 352.
CONCLUSIONS: The PPIUCD (Inserting CuT 380 A by 10 minutes after placental delivery) was demonstrably safe, effective, has high retention rate. The expulsion rate was not very high and it can be reduced with practice. With the high level of acceptance despite low levels of awareness, the government needs to develop strategies to increase public awareness of the PPIUCD through different media sources. It is also important to arrange training on PPIUCD in order to increase knowledge and skills among healthcare providers. This will also further promote PPIUCD use and aid in reduction of the expulsion rates. Cash incentives to the accepter, motivator and of course provider would bring about a substantial progress in the PPIUCD use in developing countries like India.

Entities:  

Keywords:  Intracesarean insertion; Intrauterine device; Intrauterine device insertion; Postpartum contraception

Year:  2014        PMID: 25368457      PMCID: PMC4199427          DOI: 10.1007/s13224-014-0550-3

Source DB:  PubMed          Journal:  J Obstet Gynaecol India        ISSN: 0975-6434


  4 in total

Review 1.  Immediate post-partum insertion of intrauterine devices: a Cochrane review.

Authors:  D Grimes; K Schulz; H van Vliet; N Stanwood
Journal:  Hum Reprod       Date:  2002-03       Impact factor: 6.918

2.  Immediate postplacental insertion of GYNE-T 380 and GYNE-T 380 postpartum intrauterine contraceptive devices: randomized study.

Authors:  H J Tatum; R S Beltran; R Ramos; H Van Kets; I Sivin; F H Schmidt
Journal:  Am J Obstet Gynecol       Date:  1996-11       Impact factor: 8.661

3.  Acceptability for the use of postpartum intrauterine contraceptive devices: Assiut experience.

Authors:  Safwat A Mohamed; Momen A Kamel; Omar M Shaaban; Hossam T Salem
Journal:  Med Princ Pract       Date:  2003 Jul-Sep       Impact factor: 1.927

4.  Clinical outcomes of early postplacental insertion of intrauterine contraceptive devices.

Authors:  Sevki Celen; Perran Möröy; Ayhan Sucak; Ayla Aktulay; Nuri Danişman
Journal:  Contraception       Date:  2004-04       Impact factor: 3.375

  4 in total
  14 in total

1.  Malpositioned IUCD: the menace of postpartum IUCD insertion.

Authors:  Aruna Nigam; Ayesha Ahmad; Neha Gupta; Archana Kumari
Journal:  BMJ Case Rep       Date:  2015-08-19

2.  Tale of the Tails, the Missing Postpartum IUCD Strings.

Authors:  Sujnanendra Mishra
Journal:  J Obstet Gynaecol India       Date:  2016-09-23

3.  A Cross Sectional Study on Acceptability and Safety of IUCD among Postpartum Mothers at Tertiary Care Hospital, Telangana.

Authors:  Sangeetha Jairaj; Sridhar Dayyala
Journal:  J Clin Diagn Res       Date:  2016-01-01

4.  Visibility of Strings After Postplacental Intracesarean Insertion of CuT380A and Cu375 Intrauterine Contraceptive Device: A Randomized Comparative Study.

Authors:  Kavita Agarwal; Rupali Dewan; Pratima Mittal; Abha Aggarwal
Journal:  J Obstet Gynaecol India       Date:  2017-01-30

5.  Expulsion of intrauterine devices after postpartum placement by timing of placement, delivery type, and intrauterine device type: a systematic review and meta-analysis.

Authors:  Sarah H Averbach; Yokabed Ermias; Gary Jeng; Kathryn M Curtis; Maura K Whiteman; Erin Berry-Bibee; Denise J Jamieson; Polly A Marchbanks; Naomi K Tepper; Tara C Jatlaoui
Journal:  Am J Obstet Gynecol       Date:  2020-03-03       Impact factor: 8.661

6.  Intrauterine Device Expulsion After Postpartum Placement: A Systematic Review and Meta-analysis.

Authors:  Tara C Jatlaoui; Maura K Whiteman; Gary Jeng; Naomi K Tepper; Erin Berry-Bibee; Denise J Jamieson; Polly A Marchbanks; Kathryn M Curtis
Journal:  Obstet Gynecol       Date:  2018-10       Impact factor: 7.661

7.  Post-placental Intrauterine Device Insertion Versus Delayed Intrauterine Device Insertion: An Observational Study.

Authors:  Nadia Khurshid; Shehnaz Taing; Ambreen Qureshi; Insha Jan Khanyari
Journal:  J Obstet Gynaecol India       Date:  2020-02-08

8.  A Meta-Analysis of Postpartum Copper IUD Continuation Rates in Low- and Middle-Income Countries.

Authors:  Angela Marchin; Angela Moss; Margo Harrison
Journal:  J Womens Health Dev       Date:  2021-03-18

Review 9.  Immediate postpartum use of long-acting reversible contraceptives in low- and middle-income countries.

Authors:  Margo S Harrison; Robert L Goldenberg
Journal:  Matern Health Neonatol Perinatol       Date:  2017-12-22

10.  Acceptance rate, probability of follow-up, and expulsion of postpartum intrauterine contraceptive device offered at two primary health centers, North India.

Authors:  Shashi Kant; S Archana; Arvind Kumar Singh; Farhad Ahamed; Partha Haldar
Journal:  J Family Med Prim Care       Date:  2016 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.