Catheter motion during atrial ablation due to the beating heart and respiration: impact on accuracy and spatial referencing in three-dimensional mapping.

Hanno U Klemm1, Daniel Steven, Christin Johnsen, Rodolfo Ventura, Thomas Rostock, Boris Lutomsky, Tim Risius, Thomas Meinertz, Stephan Willems.   

Abstract

BACKGROUND: The accuracy of three-dimensional mapping systems is affected by cardiac contraction and respiration.
OBJECTIVE: The study sought to determine relative motion of cardiac and thoracic structures to assess positional errors and guide the choice of an optimized spatial reference.
METHODS: Motion of catheters placed at the coronary sinus (CS), pulmonary vein (PV) ostia, left atrial (LA) isthmus and roof, cavotricuspid isthmus (CTI), and right atrial appendage (RAA) were recorded for 30 patients using Ensite-NavX. The right subclavian vein, left brachiocephalic vein, azygos vein, pulmonary arteries, and a static reference were included. The displacement from a mean position was calculated for each pair of sites. Respiration effects were assessed by the shift of the motion curve during in- and expiration phases.
RESULTS: The PVs showed a mean interpair displacement of 4.1 +/- 0.2 mm and a shift of 5.0 +/- 0.5 mm. Proximal CS references for all LA structures (4.0 +/- 1.1 mm) were superior to the static reference (4.9 +/- 0.7 mm; P = .01). In addition, the shift due to respiration was less pronounced at 3.5 +/- 0.8 mm versus 4.9 +/- 0.5 mm (P = .004), respectively. Motion of extracardiac vessels was influenced by a mean shift of 6.8 +/- 1 mm. The remote subclavian and brachiocephalic veins were more affected (7.6 +/- 0.7 mm) than the pulmonary arteries (5.9 +/- 0.4 mm; P = .002). For the CTI, a minimized mean displacement of less than 4.6 +/- 2.0 mm relative to the proximal CS, RAA, and azygos vein was found.
CONCLUSION: Respiration is the major source of relative motion, which increases with distance from the heart. For LA procedures, a proximal CS reference position is superior to a static reference position.

Entities:  

Mesh:

Year:  2007        PMID: 17467625     DOI: 10.1016/j.hrthm.2007.01.016

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  17 in total

1.  Mapping the ECG in the live rabbit heart using Ultrasound Current Source Density Imaging with coded excitation.

Authors:  Yexian Qin; Qian Li; Pier Ingram; Russell S Witte
Journal:  IEEE Netw       Date:  2012-10       Impact factor: 10.693

2.  Respiratory gating algorithm helps to reconstruct more accurate electroanatomical maps during atrial fibrillation ablation performed under spontaneous respiration.

Authors:  Gábor Széplaki; László Gellér; Emin Evren Özcan; Tamás Tahin; Orsolya Mária Kovács; Nóra Parázs; Júlia Karády; Pál Maurovich-Horvat; Szabolcs Szilágyi; István Osztheimer; Attila Tóth; Béla Merkely
Journal:  J Interv Card Electrophysiol       Date:  2016-01-27       Impact factor: 1.900

3.  Evaluation of left atrial lesions after initial and repeat atrial fibrillation ablation: lessons learned from delayed-enhancement MRI in repeat ablation procedures.

Authors:  Troy J Badger; Marcos Daccarett; Nazem W Akoum; Yaw A Adjei-Poku; Nathan S Burgon; Thomas S Haslam; Saul Kalvaitis; Suman Kuppahally; Gaston Vergara; Lori McMullen; Paul A Anderson; Eugene Kholmovski; Rob S MacLeod; Nassir F Marrouche
Journal:  Circ Arrhythm Electrophysiol       Date:  2010-03-24

4.  Automated 3D coronary sinus catheter detection using a scanning-beam digital x-ray system.

Authors:  David A P Dunkerley; Jordan M Slagowski; Lindsay E Bodart; Michael A Speidel
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

5.  Optimizing frequency and pulse shape for ultrasound current source density imaging.

Authors:  Yexian Qin; Zhaohui Wang; Pier Ingram; Qian Li; Russell S Witte
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-10       Impact factor: 2.725

Review 6.  Left atrial appendage exclusion for atrial fibrillation.

Authors:  Faisal F Syed; Christopher V DeSimone; Paul A Friedman; Samuel J Asirvatham
Journal:  Cardiol Clin       Date:  2014-10-23       Impact factor: 2.213

7.  Impact of respiration gating on image integration guided atrial fibrillation ablation.

Authors:  Emin Evren Özcan; Gabor Szeplaki; Tamas Tahin; Istvan Osztheimer; Szabolcs Szilagyi; Astrid Apor; Pal Maurovich Horvath; Hajnalka Vago; Béla Merkely; Laszlo Geller
Journal:  Clin Res Cardiol       Date:  2014-05-07       Impact factor: 5.460

Review 8.  Image integration in electroanatomic mapping.

Authors:  J Dong; T Dickfeld
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2007-09

9.  Ultrasound current source density imaging.

Authors:  Ragnar Olafsson; Russell S Witte; Sheng-Wen Huang; Matthew O'Donnell
Journal:  IEEE Trans Biomed Eng       Date:  2008-07       Impact factor: 4.538

10.  A novel four-wire-driven robotic catheter for radio-frequency ablation treatment.

Authors:  Kitaro Yoshimitsu; Takahisa Kato; Sang-Eun Song; Nobuhiko Hata
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-02-08       Impact factor: 2.924

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.