We describe the first mapping of biological current in a live heart using ultrasound current source density imaging (UCSDI). Ablation procedures that treat severe heart arrhythmias require detailed maps of the cardiac activation wave. The conventional procedure is time-consuming and limited by its poor spatial resolution (5-10 mm). UCSDI can potentially improve on existing mapping procedures. It is based on a pressure-induced change in resistivity known as the acousto-electric (AE) effect, which is spatially confined to the ultrasound focus. Data from 2 experiments are presented. A 540 kHz ultrasonic transducer (f/# = 1, focal length = 90 mm, pulse repetition frequency = 1600 Hz) was scanned over an isolated rabbit heart perfused with an excitation-contraction decoupler to reduce motion significantly while retaining electric function. Tungsten electrodes inserted in the left ventricle recorded simultaneously the AE signal and the low-frequency electrocardiogram (ECG). UCSDI displayed spatial and temporal patterns consistent with the spreading activation wave. The propagation velocity estimated from UCSDI was 0.25 +/- 0.05 mm/ms, comparable to the values obtained with the ECG signals. The maximum AE signal-to-noise ratio after filtering was 18 dB, with an equivalent detection threshold of 0.1 mA/ cm(2). This study demonstrates that UCSDI is a potentially powerful technique for mapping current flow and biopotentials in the heart.

Entities:  

Mesh:

Year:  2009        PMID: 19411215      PMCID: PMC2823813          DOI: 10.1109/TUFFC.2009.1073

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  14 in total

1.  Model-based analysis of optically mapped epicardial activation patterns and conduction velocity.

Authors:  D Sung; J H Omens; A D McCulloch
Journal:  Ann Biomed Eng       Date:  2000-09       Impact factor: 3.934

2.  Noninvasive reconstruction of three-dimensional ventricular activation sequence from the inverse solution of distributed equivalent current density.

Authors:  Zhongming Liu; Chenguang Liu; Bin He
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

3.  Atrial fibrillation ablation: location, location, location.

Authors:  Jeffrey J Goldberger
Journal:  J Cardiovasc Electrophysiol       Date:  2006-11-10

4.  Catheter motion during atrial ablation due to the beating heart and respiration: impact on accuracy and spatial referencing in three-dimensional mapping.

Authors:  Hanno U Klemm; Daniel Steven; Christin Johnsen; Rodolfo Ventura; Thomas Rostock; Boris Lutomsky; Tim Risius; Thomas Meinertz; Stephan Willems
Journal:  Heart Rhythm       Date:  2007-01-18       Impact factor: 6.343

5.  Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation.

Authors:  M A Lubinski; S Y Emelianov; M O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1999       Impact factor: 2.725

6.  Inexpensive Acoustoelectric Hydrophone For Mapping High Intensity Ultrasonic Fields.

Authors:  Russell S Witte; Tim Hall; Ragner Olafsson; Sheng-Wen Huang; Matthew O'Donnell
Journal:  J Appl Phys       Date:  2008       Impact factor: 2.546

7.  Free radicals upregulate complement expression in rabbit isolated heart.

Authors:  E J Tanhehco; K Yasojima; P L McGeer; R A Washington; B R Lucchesi
Journal:  Am J Physiol Heart Circ Physiol       Date:  2000-07       Impact factor: 4.733

8.  Experimental measurement of the acousto-electric interaction signal in saline solution.

Authors:  B Lavandier; J Jossinet; D Cathignol
Journal:  Ultrasonics       Date:  2000-09       Impact factor: 2.890

9.  Survey of physician experience, trends and outcomes with atrial fibrillation ablation.

Authors:  Steven Mickelsen; Ben Dudley; Eric Treat; John Barela; John Omdahl; Fred Kusumoto
Journal:  J Interv Card Electrophysiol       Date:  2005-04       Impact factor: 1.900

10.  Blinded correlation study of three-dimensional electro-anatomical image integration and phased array intra-cardiac echocardiography for left atrial mapping.

Authors:  Marcos Daccarett; Nathan M Segerson; Jens Günther; Georg Nölker; Klaus Gutleben; Johannes Brachmann; Nassir F Marrouche
Journal:  Europace       Date:  2007-09-06       Impact factor: 5.214

View more
  13 in total

1.  Mapping the ECG in the live rabbit heart using Ultrasound Current Source Density Imaging with coded excitation.

Authors:  Yexian Qin; Qian Li; Pier Ingram; Russell S Witte
Journal:  IEEE Netw       Date:  2012-10       Impact factor: 10.693

2.  Four-dimensional ultrasound current source density imaging of a dipole field.

Authors:  Z H Wang; R Olafsson; P Ingram; Q Li; Y Qin; R S Witte
Journal:  Appl Phys Lett       Date:  2011-09-14       Impact factor: 3.791

3.  Design considerations and performance of MEMS acoustoelectric ultrasound detectors.

Authors:  Zhaohui Wang; Pier Ingram; Charles L Greenlee; Ragnar Olafsson; Robert A Norwood; Russell S Witte
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

4.  Simulation-based validation for four- dimensional multi-channel ultrasound current source density imaging.

Authors:  Zhaohui Wang; Russell S Witte
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-03       Impact factor: 2.725

5.  Selective Mapping of Deep Brain Stimulation Lead Currents Using Acoustoelectric Imaging.

Authors:  Chet Preston; Willard S Kasoff; Russell S Witte
Journal:  Ultrasound Med Biol       Date:  2018-08-14       Impact factor: 2.998

6.  Ultrasound current source density imaging of the cardiac activation wave using a clinical cardiac catheter.

Authors:  Yexian Qin; Qian Li; Pier Ingram; Christy Barber; Zhonglin Liu; Russell S Witte
Journal:  IEEE Trans Biomed Eng       Date:  2014-08-07       Impact factor: 4.538

7.  Optimizing frequency and pulse shape for ultrasound current source density imaging.

Authors:  Yexian Qin; Zhaohui Wang; Pier Ingram; Qian Li; Russell S Witte
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-10       Impact factor: 2.725

8.  3D current source density imaging based on the acoustoelectric effect: a simulation study using unipolar pulses.

Authors:  Renhuan Yang; Xu Li; Jun Liu; Bin He
Journal:  Phys Med Biol       Date:  2011-05-31       Impact factor: 3.609

9.  Comparison study of three different image reconstruction algorithms for MAT-MI.

Authors:  Rongmin Xia; Xu Li; Bin He
Journal:  IEEE Trans Biomed Eng       Date:  2009-10-20       Impact factor: 4.538

10.  Three-dimensional noninvasive ultrasound Joule heat tomography based on the acousto-electric effect using unipolar pulses: a simulation study.

Authors:  Renhuan Yang; Xu Li; Aiguo Song; Bin He; Ruqiang Yan
Journal:  Phys Med Biol       Date:  2012-11-02       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.