Literature DB >> 25356979

Normative data for modified Box and Blocks test measuring upper-limb function via motion capture.

Jacqueline S Hebert1, Justin Lewicke, Thomas R Williams, Albert H Vette.   

Abstract

Motion analysis is an important tool for examining upper-limb function. Based on previous work demonstrating a modified Box and Blocks (BB) test with motion capture to assess prosthetic performance, we collected data in 16 nondisabled participants to establish normative kinematics for this test. Four motions of the modified BB test were analyzed to establish kinematic data for upper-limb and trunk motion. The test was repeated for right and left arms in standing and seated positions. Data were compared using a nonparametric Friedman test. No differences were found between right- and left-hand performance other than for task completion time. Small but significant differences were found for standing and seated performance, with slightly greater ranges in standing for axial trunk rotation, medial-lateral sternum displacement, and anterior-posterior hand displacement. The kinematic trajectories, however, were very consistent. The consistency in our nondisabled data suggests that normative kinematic trajectories can be defined for this task. This motion capture procedure may add to the understanding of movement in upper-limb impairment and may be useful for measuring the effect of interventions to improve upper-limb function.

Entities:  

Keywords:  Box and Blocks test; biomechanics; kinematics; limb function; motion; motion capture; outcome measures; patient outcome assessment; prosthetic performance; upper limb

Mesh:

Year:  2014        PMID: 25356979     DOI: 10.1682/JRRD.2013.10.0228

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  6 in total

1.  Prosthetic Jamming Terminal Device: A Case Study of Untethered Soft Robotics.

Authors:  Nadia Cheng; John Amend; Todd Farrell; Debra Latour; Carlos Martinez; Jen Johansson; Anthony McNicoll; Marek Wartenberg; Samuel Naseef; William Hanson; William Culley
Journal:  Soft Robot       Date:  2016-12-01       Impact factor: 8.071

2.  Targeted box and blocks test: Normative data and comparison to standard tests.

Authors:  Kimberly Kontson; Ian Marcus; Barbara Myklebust; Eugene Civillico
Journal:  PLoS One       Date:  2017-05-19       Impact factor: 3.240

3.  A Multi-User Transradial Functional-Test Socket for Validation of New Myoelectric Prosthetic Control Strategies.

Authors:  Taylor C Hansen; Abigail R Citterman; Eric S Stone; Troy N Tully; Christopher M Baschuk; Christopher C Duncan; Jacob A George
Journal:  Front Neurorobot       Date:  2022-06-17       Impact factor: 3.493

4.  Characterization of normative hand movements during two functional upper limb tasks.

Authors:  Aïda M Valevicius; Quinn A Boser; Ewen B Lavoie; Glyn S Murgatroyd; Patrick M Pilarski; Craig S Chapman; Albert H Vette; Jacqueline S Hebert
Journal:  PLoS One       Date:  2018-06-21       Impact factor: 3.240

5.  Motor Ability Evaluation of the Upper Extremity with Point-To-Point Training Movement Based on End-Effector Robot-Assisted Training System.

Authors:  Junwei Jiang; Shuai Guo; Leigang Zhang; Qing Sun
Journal:  J Healthc Eng       Date:  2022-01-28       Impact factor: 2.682

6.  Identification of forearm skin zones with similar muscle activation patterns during activities of daily living.

Authors:  Néstor J Jarque-Bou; Margarita Vergara; Joaquín L Sancho-Bru; Alba Roda-Sales; Verónica Gracia-Ibáñez
Journal:  J Neuroeng Rehabil       Date:  2018-10-29       Impact factor: 4.262

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.