Literature DB >> 24425586

Incidences, predictors, and clinical outcomes of acute and late stent malapposition detected by optical coherence tomography after drug-eluting stent implantation.

Eui Im1, Byeong-Keuk Kim, Young-Guk Ko, Dong-Ho Shin, Jung-Sun Kim, Donghoon Choi, Yangsoo Jang, Myeong-Ki Hong.   

Abstract

BACKGROUND: We investigated the incidences, predictors, and clinical outcomes of acute and late stent malapposition detected by optical coherence tomography (OCT) after drug-eluting stent implantation. METHODS AND
RESULTS: We analyzed the OCT images from 351 patients with 356 lesions who received poststent and follow-up OCT examinations. Acute stent malapposition was observed in 62% of lesions. Approximately half of the acute stent malappositions were located within the edges of the stents. Severe diameter stenosis, calcified lesions, and long stents were independent predictors of acute stent malapposition. Follow-up OCT examinations were performed 175±60 days after drug-eluting stent implantation. Thirty-one percent of lesions with acute stent malapposition remained malapposed (late-persistent stent malapposition) and were typically (72%) located within the edges of the stent. The location within the stent edges and the volume of acute stent malapposition were independent predictors of late-persistent stent malapposition. Acute stent malapposition with a volume >2.56 mm(3) differentiated late-persistent stent malapposition from resolved acute stent malapposition. Late-acquired stent malapposition was detected in 15% of all lesions and was usually (61%) located within the stent body. Late-acquired stent malapposition was more frequently associated with plaque/thrombus prolapse on poststent OCT images (70% versus 42%; P<0.001). Clinical events, including cardiovascular death, nonfatal myocardial infarction, and stent thrombosis, did not occur in patients with late stent malapposition during the follow-up period of 28.6±10.3 months after drug-eluting stent implantation.
CONCLUSIONS: Acute, late-persistent, and late-acquired stent malapposition had relatively high incidences but different predictors. The clinical outcome of stent malapposition was favorable.

Entities:  

Keywords:  coronary disease; drug-eluting stents; tomography, optical coherence

Mesh:

Substances:

Year:  2014        PMID: 24425586     DOI: 10.1161/CIRCINTERVENTIONS.113.000797

Source DB:  PubMed          Journal:  Circ Cardiovasc Interv        ISSN: 1941-7640            Impact factor:   6.546


  26 in total

1.  Optical coherence tomography analysis of the stent strut and prediction of resolved strut malapposition at 3 months after 2nd-generation drug-eluting stent implantation.

Authors:  Daisuke Izumi; Masatoshi Miyahara; Naoki Fujimoto; Shusuke Fukuoka; Masataka Sakai; Kaoru Dohi; Masaaki Ito
Journal:  Heart Vessels       Date:  2015-09-03       Impact factor: 2.037

Review 2.  Causes, assessment, and treatment of stent thrombosis--intravascular imaging insights.

Authors:  Daniel S Ong; Ik-Kyung Jang
Journal:  Nat Rev Cardiol       Date:  2015-03-17       Impact factor: 32.419

3.  Cut-off value of mal-apposition volume and depth for resolution at early phase of acute incomplete stent apposition after CoCr-EES implantation.

Authors:  Yohei Uchimura; Tomonori Itoh; Hideto Oda; Yuya Taguchi; Wataru Sasaki; Kyosuke Kaneko; Tsubasa Sakamoto; Iwao Goto; Masafumi Sakuma; Masaru Ishida; Tatsuo Kikuchi; Daisuke Terashita; Hiromasa Otake; Yoshihiro Morino; Toshiro Shinke
Journal:  Int J Cardiovasc Imaging       Date:  2019-06-29       Impact factor: 2.357

Review 4.  Optical coherence tomography-guided percutaneous coronary intervention: a review of current clinical applications.

Authors:  Kazumasa Kurogi; Masanobu Ishii; Nobuyasu Yamamoto; Kenshi Yamanaga; Kenichi Tsujita
Journal:  Cardiovasc Interv Ther       Date:  2021-01-17

Review 5.  Vascular Lesion-Specific Drug Delivery Systems: JACC State-of-the-Art Review.

Authors:  David Marlevi; Elazer R Edelman
Journal:  J Am Coll Cardiol       Date:  2021-05-18       Impact factor: 24.094

6.  Calcified lesions treated with rotational atherectomy-much more advantages than real hazards.

Authors:  Piotr Kübler; Krzysztof Reczuch
Journal:  J Thorac Dis       Date:  2018-09       Impact factor: 2.895

7.  Mechanisms of stent thrombosis: insights from optical coherence tomography.

Authors:  Seung-Yul Lee; Myeong-Ki Hong
Journal:  J Thorac Dis       Date:  2016-06       Impact factor: 2.895

8.  Randomized comparison of acute stent malapposition between platinum-chromium versus cobalt-chromium everolimus-eluting stents.

Authors:  Byeong-Keuk Kim; Dong-Ho Shin; Jung-Sun Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2014-10-28       Impact factor: 2.357

Review 9.  A Practical Approach to Assessing Stent Results with IVUS or OCT.

Authors:  Daisuke Hachinohe; Satoru Mitomo; Luciano Candilio; Azeem Latib
Journal:  Methodist Debakey Cardiovasc J       Date:  2018 Jan-Mar

10.  Vascular Response to Experimental Stent Malapposition and Under-Expansion.

Authors:  Caroline C O'Brien; Augusto C Lopes; Kumaran Kolandaivelu; Mie Kunio; Jonathan Brown; Vijaya B Kolachalama; Claire Conway; Lynn Bailey; Peter Markham; Marco Costa; James Ware; Elazer R Edelman
Journal:  Ann Biomed Eng       Date:  2016-01-05       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.