Literature DB >> 20403478

Intravascular ultrasound assessment of cobalt chromium versus stainless steel drug-eluting stent expansion.

Yong He1, Akiko Maehara, Gary S Mintz, Harpreet Bharaj, Celia Castellanos, Srinivas Kesanakurthy, Xiaofan Wu, Ning Guo, So-Yeon Choi, Martin B Leon, Gregg W Stone, Roxana Mehran, Leroy E Rabbani, Jeffrey W Moses.   

Abstract

It is not clear whether the thin struts and different alloy of a cobalt chromium stent will cause greater acute stent recoil compared to conventional stainless steel stents. We used postintervention intravascular ultrasound (IVUS) examinations to study 99 patients with 116 stented lesions: 61 Xience/Promus stents (cobalt chromium stent group) and 27 Taxus Liberté and 28 Cypher stents (stainless steel stent group). The IVUS images were obtained before and immediately after stent implantation with only the stent-delivery balloon. The ratio of the IVUS-measured to manufacturer-predicted stent diameter and area was the measure of acute stent recoil and expansion. The baseline patient characteristics, lesion morphology, and procedural details were comparable between the 2 groups. The ratio of the IVUS-measured to manufacturer-predicted stent diameter and area was 0.74 versus 0.73 (p = 0.57) and 0.63 versus 0.63 (p = 0.69), respectively, for the cobalt chromium and stainless steel stents. In conclusion, the acute performance of Xience/Promus was similar to that of previous stainless steel stents, and the thinner cobalt chromium metallic platform did not compromise the radial strength of the stent. Copyright 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20403478     DOI: 10.1016/j.amjcard.2009.12.042

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  3 in total

1.  Preventable effects of bare-metal stent on restenosis after everolimus-eluting stent deployment.

Authors:  Akihiro Shirakabe; Masamichi Takano; Masanori Yamamoto; Osamu Kurihara; Nobuaki Kobayashi; Masato Matsushita; Masafumi Tsurumi; Hirotake Okazaki; Noritake Hata; Wataru Shimizu
Journal:  Heart Vessels       Date:  2014-10-21       Impact factor: 2.037

2.  Randomized comparison of acute stent malapposition between platinum-chromium versus cobalt-chromium everolimus-eluting stents.

Authors:  Byeong-Keuk Kim; Dong-Ho Shin; Jung-Sun Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2014-10-28       Impact factor: 2.357

3.  A randomized, prospective, intercontinental evaluation of a bioresorbable polymer sirolimus-eluting coronary stent system: the CENTURY II (Clinical Evaluation of New Terumo Drug-Eluting Coronary Stent System in the Treatment of Patients with Coronary Artery Disease) trial.

Authors:  Shigeru Saito; Mariano Valdes-Chavarri; Gert Richardt; Raul Moreno; Andrés Iniguez Romo; Emanuele Barbato; Didier Carrie; Kenji Ando; Bela Merkely; Ran Kornowski; Hélène Eltchaninoff; Stefan James; William Wijns
Journal:  Eur Heart J       Date:  2014-05-19       Impact factor: 29.983