Literature DB >> 25343688

A comparative study between currently used methods and Small Volume-Cone Beam Tomography for surgical placement of mini implants.

Melissa Landin1, Aniket Jadhav, Sumit Yadav, Aditya Tadinada.   

Abstract

OBJECTIVE: To compare the outcome of mini implant placement by four different methods: blind placement, a single periapical radiograph (PA), a single panoramic radiograph, and a small-volume cone-beam computed tomography (SV-CBCT). Our hypothesis was that SV-CBCT, with its high resolution, low radiation dose, and three-dimensional depiction of area of interest would yield superior diagnostic information in assessing the potential anchorage site compared to currently used methods that often result in undesired root perforations.
MATERIALS AND METHODS: Potential mini implant sites of 20 dentate or partially dentate human skulls were imaged using three different imaging modalities: PA, panoramic radiograph, and SV-CBCT. Mini implants were placed in 10 maxillary and 10 mandibular randomized sites blindly and using each of the three imaging modalities. Large-volume CBCT scans done postoperatively were used to detect root perforation. Two oral radiologists analyzed the images for perforation of root structures at each site.
RESULTS: There was significantly (P < .05) less root perforation with SV-CBCT when compared with other imaging modalities. Fifty-five percent of mini implants placed blindly, 60% of mini implants placed using PA, and 50% of mini implants placed using a panoramic radiograph perforated a root structure, whereas only 5% of mini implants placed using SV-CBCT perforated a root structure.
CONCLUSIONS: Preoperative evaluation of potential mini implant insertion sites using SV-CBCT aids in predictable placement and results in the least amount of root perforation.

Entities:  

Keywords:  Mini implants; SV-CBCT

Mesh:

Substances:

Year:  2014        PMID: 25343688      PMCID: PMC8612416          DOI: 10.2319/042214-298.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  19 in total

1.  Effective dose range for dental cone beam computed tomography scanners.

Authors:  Ruben Pauwels; Jilke Beinsberger; Bruno Collaert; Chrysoula Theodorakou; Jessica Rogers; Anne Walker; Lesley Cockmartin; Hilde Bosmans; Reinhilde Jacobs; Ria Bogaerts; Keith Horner
Journal:  Eur J Radiol       Date:  2010-12-31       Impact factor: 3.528

2.  Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants.

Authors:  Toru Deguchi; Miho Nasu; Kaoru Murakami; Toshinori Yabuuchi; Hiroshi Kamioka; Teruko Takano-Yamamoto
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-06       Impact factor: 2.650

3.  Two- and three-dimensional orthodontic imaging using limited cone beam-computed tomography.

Authors:  Akira Nakajima; Glenn T Sameshima; Yoshinori Arai; Yoshito Homme; Noriyoshi Shimizu; Harry Dougherty
Journal:  Angle Orthod       Date:  2005-11       Impact factor: 2.079

4.  Mini-implant anchorage for en-masse retraction of maxillary anterior teeth: a clinical cephalometric study.

Authors:  Madhur Upadhyay; Sumit Yadav; Sameer Patil
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-12       Impact factor: 2.650

5.  Evaluation of interdental space of the maxillary posterior area for orthodontic mini-implants with cone-beam computed tomography.

Authors:  Seong-Hun Kim; Hyeong-Gun Yoon; Yong-Suk Choi; Eui-Hwan Hwang; Yoon-Ah Kook; Gerald Nelson
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-05       Impact factor: 2.650

6.  Healing of the roots and surrounding structures after intentional damage with miniscrew implants.

Authors:  Carmen E Brisceno; P Emile Rossouw; Roberto Carrillo; Robert Spears; Peter H Buschang
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-03       Impact factor: 2.650

7.  Technological advances in nontraditional orthodontics.

Authors:  Andrea M Bonnick; Mark Nalbandian; Marianne S Siewe
Journal:  Dent Clin North Am       Date:  2011-07

Review 8.  Clinical effectiveness of orthodontic miniscrew implants: a meta-analysis.

Authors:  M A Papadopoulos; S N Papageorgiou; I P Zogakis
Journal:  J Dent Res       Date:  2011-05-18       Impact factor: 6.116

9.  Patient risk related to common dental radiographic examinations: the impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation.

Authors:  John B Ludlow; Laura E Davies-Ludlow; Stuart C White
Journal:  J Am Dent Assoc       Date:  2008-09       Impact factor: 3.634

Review 10.  Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis.

Authors:  Spyridon N Papageorgiou; Ioannis P Zogakis; Moschos A Papadopoulos
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-11       Impact factor: 2.650

View more
  6 in total

Review 1.  Applications of Cone Beam Computed Tomography in Orthodontics: A Review.

Authors:  Aditya Tadinada; Alana Marczak; Sumit Yadav; Padma M Mukherjee
Journal:  Turk J Orthod       Date:  2016-09-01

Review 2.  Two-dimensional radiographs versus cone-beam computed tomography in planning mini-implant placement: A systematic review.

Authors:  Gabriela-Franco-da Rosa Caetano; Mariana-Quirino-Silveira Soares; Luciana-Butini Oliveira; José-Luiz-Cintra Junqueira; Monikelly-do Carmo-Chagas Nascimento
Journal:  J Clin Exp Dent       Date:  2022-08-01

3.  Accuracy of Mini-Implant Placement Using a Computer-Aided Designed Surgical Guide, with Information of Intraoral Scan and the Use of a Cone-Beam CT.

Authors:  Georgios Vasoglou; Ioanna Stefanidaki; Konstantinos Apostolopoulos; Evmorfia Fotakidou; Michail Vasoglou
Journal:  Dent J (Basel)       Date:  2022-06-08

Review 4.  Clinical guidelines for dental cone-beam computed tomography.

Authors:  Takafumi Hayashi; Yoshinori Arai; Toru Chikui; Sachiko Hayashi-Sakai; Kazuya Honda; Hiroko Indo; Taisuke Kawai; Kaoru Kobayashi; Shumei Murakami; Masako Nagasawa; Munetaka Naitoh; Eiji Nakayama; Yutaka Nikkuni; Hideyoshi Nishiyama; Noriaki Shoji; Shigeaki Suenaga; Ray Tanaka
Journal:  Oral Radiol       Date:  2018-01-11       Impact factor: 1.852

5.  Correlation between tooth size-arch length discrepancy and interradicular distances measured on CBCT and panoramic radiograph: an evaluation for miniscrew insertion.

Authors:  Michele Tepedino; Marie A Cornelis; Claudio Chimenti; Paolo M Cattaneo
Journal:  Dental Press J Orthod       Date:  2018 Sep-Oct

6.  Diagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites.

Authors:  Aditya Tadinada; Alana Marczak; Sumit Yadav
Journal:  Imaging Sci Dent       Date:  2017-09-21
  6 in total