Literature DB >> 18762634

Patient risk related to common dental radiographic examinations: the impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation.

John B Ludlow1, Laura E Davies-Ludlow, Stuart C White.   

Abstract

BACKGROUND: In 2007, the International Commission on Radiological Protection (ICRP) revised estimates of the radiosensitivity of tissues including those in the maxillofacial region. The authors conducted a study to reassess patients' risk related to common dental radiographic exposures using the 2007 ICRP recommendations.
METHODS: The authors used a tissue-equivalent head phantom to measure dose. They calculated effective doses by using both 1990 and revised 2007 ICRP recommendations. Effective dose is a calculation that takes into consideration the different sensitivities of organs to long-term effects from ionizing radiation. It is the preferred method for comparing doses between different types of exposures.
RESULTS: Effective doses (per the 2007 ICRP) in microsieverts were as follows: full-mouth radiographs (FMX) with photo-stimulable phosphor (PSP) storage or F-speed film with rectangular collimation, 34.9 microSv; four-image posterior bitewings with PSP or F-speed film with rectangular collimation, 5.0 microSv; FMX using PSP or F-speed film with round collimation, 170.7 microSv; FMX with D-speed film and round collimation, 388 microSv; panoramic Orthophos XG (Sirona Group, Bensheim, Germany) with charge-coupled device (CCD), 14.2 microSv; panoramic ProMax (Planmeca, Helsinki, Finland) with CCD, 24.3 microSv; posteroanterior cephalogram with PSP, 5.1 microSv; and lateral cephalogram with PSP, 5.6 microSv. These values are 32 to 422 percent higher than those determined according to the 1990 ICRP guidelines.
CONCLUSIONS: Although radiographs are an indispensable diagnostic tool, the increased effective doses of common intraoral and extraoral imaging techniques are high enough to warrant reconsideration of means to reduce patients' exposure. CLINICAL IMPLICATIONS: Clinicians can reduce patients' dose substantively by using digital receptors or F-speed film instead of D-speed film, rectangular collimation instead of round collimation and radiographic selection criteria.

Entities:  

Mesh:

Year:  2008        PMID: 18762634     DOI: 10.14219/jada.archive.2008.0339

Source DB:  PubMed          Journal:  J Am Dent Assoc        ISSN: 0002-8177            Impact factor:   3.634


  91 in total

1.  Necessity of 3D visualization for the removal of lower wisdom teeth: required sample size to prove non-inferiority of panoramic radiography compared to CBCT.

Authors:  Felix Roeder; Daniel Wachtlin; Ralf Schulze
Journal:  Clin Oral Investig       Date:  2011-04-26       Impact factor: 3.573

2.  Ex vivo comparison of Galileos cone beam CT and intraoral radiographs in detecting occlusal caries.

Authors:  S Rathore; D Tyndall; Jt Wright; E Everett
Journal:  Dentomaxillofac Radiol       Date:  2011-12-19       Impact factor: 2.419

3.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 1: the influence of X-ray generator on periodontal measurements using conventional and digital receptors.

Authors:  Bart Vandenberghe; Livia Corpas; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-05       Impact factor: 3.573

4.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 2: the influence of intra-oral image receptor on periodontal measurements.

Authors:  Bart Vandenberghe; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-12       Impact factor: 3.573

Review 5.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

6.  Age determination in asylum seekers: physicians should not be implicated.

Authors:  Pieter J J Sauer; Alf Nicholson; David Neubauer
Journal:  Eur J Pediatr       Date:  2015-09-18       Impact factor: 3.183

7.  Ex vivo evaluation of new 2D and 3D dental radiographic technology for detecting caries.

Authors:  Laurence Gaalaas; Donald Tyndall; André Mol; Eric T Everett; Ananta Bangdiwala
Journal:  Dentomaxillofac Radiol       Date:  2015-12-16       Impact factor: 2.419

8.  Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography.

Authors:  John B Ludlow; Cameron Walker
Journal:  Am J Orthod Dentofacial Orthop       Date:  2013-12       Impact factor: 2.650

9.  Small field of view cone beam CT temporomandibular joint imaging dosimetry.

Authors:  T D Lukat; J C M Wong; E W N Lam
Journal:  Dentomaxillofac Radiol       Date:  2013-09-18       Impact factor: 2.419

Review 10.  Clinical guidelines for dental cone-beam computed tomography.

Authors:  Takafumi Hayashi; Yoshinori Arai; Toru Chikui; Sachiko Hayashi-Sakai; Kazuya Honda; Hiroko Indo; Taisuke Kawai; Kaoru Kobayashi; Shumei Murakami; Masako Nagasawa; Munetaka Naitoh; Eiji Nakayama; Yutaka Nikkuni; Hideyoshi Nishiyama; Noriaki Shoji; Shigeaki Suenaga; Ray Tanaka
Journal:  Oral Radiol       Date:  2018-01-11       Impact factor: 1.852

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.