Literature DB >> 19061808

Mini-implant anchorage for en-masse retraction of maxillary anterior teeth: a clinical cephalometric study.

Madhur Upadhyay1, Sumit Yadav, Sameer Patil.   

Abstract

INTRODUCTION: This study was conducted to determine the efficiency of mini-implants as intraoral anchorage units for en-masse retraction of the 6 maxillary anterior teeth when the first premolars are extracted compared with conventional methods of anchorage reinforcement.
METHODS: Thirty patients requiring high anchorage after extraction of the maxillary first premolars were selected for this study. They were divided into 2 groups of 15 each. In the first group (G1), mini-implants were used for en-masse retraction; in the second group (G2), conventional methods of anchorage preservation were followed. Horizontal, vertical, and angular positions of the maxillary first molar and central incisor were evaluated cephalometrically before and after orthodontic retraction.
RESULTS: The maxillary first molars in the G1 patients showed net distal movement of 0.55 mm, and mesial movement of 1.95 mm was found in G2. The differences were statistically significant. Distal tipping of the first molar of -0.13 degrees+/-3.63 degrees was seen in G1, and mesial tipping of 3.7 degrees+/-3.9 degrees was observed in G2. No significant differences were found in the rates of incisor retraction between the 2 groups. However, G1 showed more than 2 mm of incisor intrusion; this was statistically significant.
CONCLUSIONS: Mini-implants are efficient for intraoral anchorage reinforcement for en-masse retraction and intrusion of maxillary anterior teeth. No anchorage loss was seen in either the horizontal or the vertical direction in G1 when compared with G2. However, a statistically significant decrease in intermolar width was noted in G1.

Entities:  

Mesh:

Year:  2008        PMID: 19061808     DOI: 10.1016/j.ajodo.2006.10.025

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  35 in total

1.  En-masse Retraction of the Maxillary Anterior Teeth by Applying Force from Four Different Levels - A Finite Element Study.

Authors:  Chetan S; Kanhoba M Keluskar; Vikram N Vasisht; Siddharth Revankar
Journal:  J Clin Diagn Res       Date:  2014-09-20

2.  Treatment of Class II, Division 2 Malocclusion with Miniscrew Supported En-Masse Retraction: Is Deepbite Really an Obstacle for Extraction Treatment?

Authors:  Nilüfer İrem Tunçer; Ayça Arman Özçırpıcı
Journal:  Turk J Orthod       Date:  2017-09-01

3.  Direct versus indirect loading of orthodontic miniscrew implants-an FEM analysis.

Authors:  C Holberg; P Winterhalder; N Holberg; I Rudzki-Janson; A Wichelhaus
Journal:  Clin Oral Investig       Date:  2012-10-31       Impact factor: 3.573

4.  Group Distal Movement of Teeth using Micro-Screw-Implant Anchorage-A Case Report.

Authors:  Biju Kalarickal
Journal:  J Clin Diagn Res       Date:  2014-05-15

5.  Comparative evaluation of anchorage reinforcement between orthodontic implants and conventional anchorage in orthodontic management of bimaxillary dentoalveolar protrusion.

Authors:  S S Chopra; Manish Mukherjee; Rajat Mitra; Gagan Deep Kochar; Abhijeet Kadu
Journal:  Med J Armed Forces India       Date:  2016-03-02

Review 6.  Reinforcement of anchorage during orthodontic brace treatment with implants or other surgical methods.

Authors:  Safa Jambi; Tanya Walsh; Jonathan Sandler; Philip E Benson; Richard M Skeggs; Kevin D O'Brien
Journal:  Cochrane Database Syst Rev       Date:  2014-08-19

7.  Comparison of skeletal and conventional anchorage methods in conjunction with pre-operative decompensation of a skeletal class III malocclusion.

Authors:  Benedict Wilmes; Gudrun Olthoff; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2009-08-02       Impact factor: 1.938

8.  Distalization pattern of the maxillary arch depending on the number of orthodontic miniscrews.

Authors:  Till E Bechtold; Jin-Wook Kim; Tae-Hyun Choi; Young-Chel Park; Kee-Joon Lee
Journal:  Angle Orthod       Date:  2012-09-12       Impact factor: 2.079

9.  A comparative anchorage control study between conventional and self-ligating bracket systems using differential moments.

Authors:  Marcio Rodrigues de Almeida; Francisco Herrero; Amine Fattal; Amirparviz R Davoody; Ravindra Nanda; Flavio Uribe
Journal:  Angle Orthod       Date:  2013-06-07       Impact factor: 2.079

10.  A comparative study between currently used methods and Small Volume-Cone Beam Tomography for surgical placement of mini implants.

Authors:  Melissa Landin; Aniket Jadhav; Sumit Yadav; Aditya Tadinada
Journal:  Angle Orthod       Date:  2014-10-24       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.