Literature DB >> 25325326

Abdominal 4D flow MR imaging in a breath hold: combination of spiral sampling and dynamic compressed sensing for highly accelerated acquisition.

Hadrien Dyvorne1, Ashley Knight-Greenfield, Guido Jajamovich, Cecilia Besa, Yong Cui, Aurélien Stalder, Michael Markl, Bachir Taouli.   

Abstract

PURPOSE: To develop a highly accelerated phase-contrast cardiac-gated volume flow measurement (four-dimensional [4D] flow) magnetic resonance (MR) imaging technique based on spiral sampling and dynamic compressed sensing and to compare this technique with established phase-contrast imaging techniques for the quantification of blood flow in abdominal vessels.
MATERIALS AND METHODS: This single-center prospective study was compliant with HIPAA and approved by the institutional review board. Ten subjects (nine men, one woman; mean age, 51 years; age range, 30-70 years) were enrolled. Seven patients had liver disease. Written informed consent was obtained from all participants. Two 4D flow acquisitions were performed in each subject, one with use of Cartesian sampling with respiratory tracking and the other with use of spiral sampling and a breath hold. Cartesian two-dimensional (2D) cine phase-contrast images were also acquired in the portal vein. Two observers independently assessed vessel conspicuity on phase-contrast three-dimensional angiograms. Quantitative flow parameters were measured by two independent observers in major abdominal vessels. Intertechnique concordance was quantified by using Bland-Altman and logistic regression analyses.
RESULTS: There was moderate to substantial agreement in vessel conspicuity between 4D flow acquisitions in arteries and veins (κ = 0.71 and 0.61, respectively, for observer 1; κ = 0.71 and 0.44 for observer 2), whereas more artifacts were observed with spiral 4D flow (κ = 0.30 and 0.20). Quantitative measurements in abdominal vessels showed good equivalence between spiral and Cartesian 4D flow techniques (lower bound of the 95% confidence interval: 63%, 77%, 60%, and 64% for flow, area, average velocity, and peak velocity, respectively). For portal venous flow, spiral 4D flow was in better agreement with 2D cine phase-contrast flow (95% limits of agreement: -8.8 and 9.3 mL/sec, respectively) than was Cartesian 4D flow (95% limits of agreement: -10.6 and 14.6 mL/sec).
CONCLUSION: The combination of highly efficient spiral sampling with dynamic compressed sensing results in major acceleration for 4D flow MR imaging, which allows comprehensive assessment of abdominal vessel hemodynamics in a single breath hold.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25325326      PMCID: PMC4372461          DOI: 10.1148/radiol.14140973

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  28 in total

1.  Real-time volumetric flow measurements with complex-difference MRI.

Authors:  Richard B Thompson; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-12       Impact factor: 4.668

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Encoding strategies for three-direction phase-contrast MR imaging of flow.

Authors:  N J Pelc; M A Bernstein; A Shimakawa; G H Glover
Journal:  J Magn Reson Imaging       Date:  1991 Jul-Aug       Impact factor: 4.813

4.  Variability of consecutive in vivo MR flow measurements in the main portal vein.

Authors:  A K Hara; D J Burkart; C D Johnson; J P Felmlee; R L Ehman; D M Ilstrup; W S Harmsen
Journal:  AJR Am J Roentgenol       Date:  1996-06       Impact factor: 3.959

5.  Doppler US measurement of portal venous flow: variability in healthy fasting volunteers.

Authors:  E K Paulson; M A Kliewer; M G Frederick; M T Keogan; D M DeLong; R C Nelson
Journal:  Radiology       Date:  1997-03       Impact factor: 11.105

6.  Gadgetron: an open source framework for medical image reconstruction.

Authors:  Michael Schacht Hansen; Thomas Sangild Sørensen
Journal:  Magn Reson Med       Date:  2012-07-12       Impact factor: 4.668

7.  Semiautomated method for noise reduction and background phase error correction in MR phase velocity data.

Authors:  P G Walker; G B Cranney; M B Scheidegger; G Waseleski; G M Pohost; A P Yoganathan
Journal:  J Magn Reson Imaging       Date:  1993 May-Jun       Impact factor: 4.813

8.  Quantification of thoracic blood flow using volumetric magnetic resonance imaging with radial velocity encoding: in vivo validation.

Authors:  Alex Frydrychowicz; Oliver Wieben; Eric Niespodzany; Scott B Reeder; Kevin M Johnson; Christopher J François
Journal:  Invest Radiol       Date:  2013-12       Impact factor: 6.016

9.  Accelerated aortic flow assessment with compressed sensing with and without use of the sparsity of the complex difference image.

Authors:  Yongjun Kwak; Seunghoon Nam; Mehmet Akçakaya; Tamer A Basha; Beth Goddu; Warren J Manning; Vahid Tarokh; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-10-12       Impact factor: 4.668

10.  Time-resolved three-dimensional phase-contrast MRI.

Authors:  Michael Markl; Frandics P Chan; Marcus T Alley; Kris L Wedding; Mary T Draney; Chris J Elkins; David W Parker; Ryan Wicker; Charles A Taylor; Robert J Herfkens; Norbert J Pelc
Journal:  J Magn Reson Imaging       Date:  2003-04       Impact factor: 4.813

View more
  34 in total

1.  Portal hypertension in patients with cirrhosis: indirect assessment of hepatic venous pressure gradient by measuring azygos flow with 2D-cine phase-contrast magnetic resonance imaging.

Authors:  Hervé Gouya; Sophie Grabar; Olivier Vignaux; Anastasia Saade; Stanislas Pol; Paul Legmann; Philippe Sogni
Journal:  Eur Radiol       Date:  2015-09-15       Impact factor: 5.315

2.  Four-dimensional flow MRI for evaluation of post-stenotic turbulent flow in a phantom: comparison with flowmeter and computational fluid dynamics.

Authors:  Jihoon Kweon; Dong Hyun Yang; Guk Bae Kim; Namkug Kim; MunYoung Paek; Aurelien F Stalder; Andreas Greiser; Young-Hak Kim
Journal:  Eur Radiol       Date:  2016-01-08       Impact factor: 5.315

Review 3.  Four-dimensional flow magnetic resonance imaging in cirrhosis.

Authors:  Zoran Stankovic
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

4.  k-t accelerated aortic 4D flow MRI in under two minutes: Feasibility and impact of resolution, k-space sampling patterns, and respiratory navigator gating on hemodynamic measurements.

Authors:  Emilie Bollache; Alex J Barker; Ryan Scott Dolan; James C Carr; Pim van Ooij; Rouzbeh Ahmadian; Alex Powell; Jeremy D Collins; Julia Geiger; Michael Markl
Journal:  Magn Reson Med       Date:  2017-03-07       Impact factor: 4.668

5.  Aortic 4D flow MRI in 2 minutes using compressed sensing, respiratory controlled adaptive k-space reordering, and inline reconstruction.

Authors:  Liliana E Ma; Michael Markl; Kelvin Chow; Hyungkyu Huh; Christoph Forman; Alireza Vali; Andreas Greiser; James Carr; Susanne Schnell; Alex J Barker; Ning Jin
Journal:  Magn Reson Med       Date:  2019-02-25       Impact factor: 4.668

6.  2-D magnetic resonance spectroscopic imaging of the pediatric brain using compressed sensing.

Authors:  Rohini Vidya Shankar; Houchun H Hu; Nutandev Bikkamane Jayadev; John C Chang; Vikram D Kodibagkar
Journal:  Pediatr Radiol       Date:  2019-08-28

Review 7.  Cross-sectional imaging of congenital and acquired abnormalities of the portal venous system.

Authors:  Mustafa Özbayrak; Servet Tatlı
Journal:  Diagn Interv Radiol       Date:  2016 Nov-Dec       Impact factor: 2.630

Review 8.  Noninvasive imaging assessment of portal hypertension.

Authors:  Paul Kennedy; Octavia Bane; Stefanie J Hectors; Aaron Fischman; Thomas Schiano; Sara Lewis; Bachir Taouli
Journal:  Abdom Radiol (NY)       Date:  2020-09-14

9.  Improved quantification and mapping of anomalous pulmonary venous flow with four-dimensional phase-contrast MRI and interactive streamline rendering.

Authors:  Albert Hsiao; Ufra Yousaf; Marcus T Alley; Michael Lustig; Frandics Pak Chan; Beverley Newman; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2015-04-24       Impact factor: 4.813

10.  4D flow MR imaging of the portal venous system: a feasibility study in children.

Authors:  Keyur Parekh; Michael Markl; Michael Rose; Susanne Schnell; Andrada Popescu; Cynthia K Rigsby
Journal:  Eur Radiol       Date:  2016-05-18       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.