| Literature DB >> 25319073 |
Jun Shang1, Wei Kong2, Yan-yang Wang3, Zhe Ding4, Gang Yan5, Hong Zhe6.
Abstract
BACKGROUND: To compare the dosimetric differences among fixed field intensity-modulated radiation therapy (IMRT), single-arc volumetric-modulated arc therapy (SA-VMAT) and double-arc volumetric-modulated arc therapy (DA-VMAT) plans in rectal cancer.Entities:
Mesh:
Year: 2014 PMID: 25319073 PMCID: PMC4205282 DOI: 10.1186/s13014-014-0219-1
Source DB: PubMed Journal: Radiat Oncol ISSN: 1748-717X Impact factor: 3.481
Dosimetric parameters comparison among IMRT, SA-VMAT and DA-VMAT technique for PTV (mean ± standard deviation)
|
|
|
|
|
| |
|---|---|---|---|---|---|
| Dmean (Gy) | 52.0 ± 0.2 | 52.0 ± 0.4 | 51.6 ± 0.2 | 0.167 | 0.001 |
| D2% (Gy) | 54.1 ± 0.2 | 54.0 ± 0.8 | 53.1 ± 0.3 | 0.366 | 0.001 |
| D98% (Gy) | 49.2 ± 0.3 | 49.3 ± 0.2 | 49.5 ± 0.2 | 0.230 | 0.015 |
| V95 (%) | 99.6 ± 0.3 | 99.9 ± 0.1 | 99.9 ± 0.1 | 0.001 | 0.001 |
| V107 (%) | 10.2 ± 5.1 | 5.3 ± 3.9 | 0.6 ± 0.4 | 0.017 | 0.001 |
| CI | 1.23 ± 0.05 | 1.28 ± 0.07 | 1.21 ± 0.07 | 0.006 | 0.305 |
| MU | 499.0 ± 41.6 | 418.5 ± 41.9 | 438.8 ± 31.7 | 0.001 | 0.001 |
| Treatment time (min) | 8.0 ± 0.7 | 1.5 ± 0.2 | 3.0 ± 0.3 | 0.001 | 0.001 |
IMRT: intensity modulated radiotherapy, SA-VMAT: single-arc volumetric modulated arc therapy, DA-VMAT: double-arc volumetric modulated arc therapy, PTV: Planning Target Volume, CI: conformity index, MU: monitor units.
Figure 1Representation of isodose distribution in axial, coronal and sagittal views for fixed IMRT (the first line) and DA-VMAT (the second line). IMRT: intensity modulated radiotherapy, DA-VMAT: double-arc volumetric modulated arc therapy.
Figure 2Dose-volume histograms for PTV of an individual patient in present study. IMRT: intensity modulated radiotherapy, DA-VMAT: double-arc volumetric modulated arc therapy.
Dosimetric parameters comparison for OAR (mean ± standard deviation)
|
|
|
|
|
| ||
|---|---|---|---|---|---|---|
| Small bowel | Dmean (Gy) | 12.1 ± 8.0 | 15.5 ± 7.7 | 15.3 ± 7.6 | 0.001 | 0.002 |
| D2% (Gy) | 35.7 ± 12.1 | 40.0 ± 10.2 | 39.6 ± 10.0 | 0.005 | 0.009 | |
| V15 (cc) | 132.0 ± 110.2 | 185.8 ± 130.0 | 186.4 ± 128.8 | 0.004 | 0.005 | |
| V30 (cc) | 48.8 ± 20.0 | 77.5 ± 21.0 | 78.8 ± 21.5 | 0.001 | 0.002 | |
| Bladder | Dmean (Gy) | 39.0 ± 3.3 | 42.2 ± 4.0 | 40.0 ± 3.6 | 0.001 | 0.074 |
| D2% (Gy) | 52.9 ± 0.6 | 53.2 ± 0.7 | 52.4 ± 0.5 | 0.132 | 0.005 | |
| V30 (cc) | 437.1 ± 156.5 | 479.4 ± 176.5 | 463.2 ± 191.2 | 0.061 | 0.460 | |
| V40 (cc) | 281.9 ± 118.9 | 366.2 ± 155.8 | 321.1 ± 167.1 | 0.002 | 0.140 | |
| V50 (cc) | 112.0 ± 55.6 | 185.7 ± 107.4 | 151.1 ± 115.6 | 0.001 | 0.112 | |
| Femur heads | Dmean (Gy) | 19.9 ± 4.1 | 23.2 ± 3.4 | 24.3 ± 2.8 | 0.025 | 0.012 |
| D10% (Gy) | 28.2 ± 5.5 | 29.6 ± 4.3 | 31.5 ± 4.1 | 0.173 | 0.047 | |
| Healthy tissues | V5 (cc) | 9454.9 ± 1999.3 | 9827.4 ± 2153.3 | 9815.3 ± 2142.0 | 0.001 | 0.001 |
| V10 (cc) | 7833.9 ± 1591.8 | 8167.6 ± 1789.4 | 8331.8 ± 1733.7 | 0.013 | 0.001 | |
| V20 (cc) | 5224.2 ± 1084.5 | 4721.8 ± 884.3 | 4750.7 ± 876.5 | 0.002 | 0.005 |
OAR: organ at risk, IMRT: intensity modulated radiotherapy, SA-VMAT: single-arc volumetric modulated arc therapy, DA-VMAT: double-arc volumetric modulated arc therapy.
Figure 3Dose-volume histograms for small bowel and bladder of an individual patient in present study. IMRT: intensity modulated radiotherapy, DA-VMAT: double-arc volumetric modulated arc therapy.
Figure 4Dose-volume histograms for femur head and healthy tissue of an individual patient in present study. IMRT: intensity modulated radiotherapy, DA-VMAT: double-arc volumetric modulated arc therapy.