| Literature DB >> 29178585 |
Amandeep S Taggar1,2, Darren Graham3, Elizabeth Kurien3,4, James L Gräfe5.
Abstract
PURPOSE: To compare dosimetric and treatment delivery parameter differences between volumetric-modulated arc radiotherapy (VMAT) and intensity-modulated radiotherapy (IMRT) for large volume retroperitoneal sarcomas (RPS).Entities:
Keywords: dosimetry; intensity-modulated radiotherapy (IMRT); retroperitoneal sarcoma; volumetric-modulated arc therapy (VMAT)
Mesh:
Year: 2017 PMID: 29178585 PMCID: PMC5768010 DOI: 10.1002/acm2.12230
Source DB: PubMed Journal: J Appl Clin Med Phys ISSN: 1526-9914 Impact factor: 2.102
Patient, tumor, and treatment characteristics
| Patient characteristics | |
| Age, median (range) | 62.0 yr (32.2–76.2 yr) |
| Male, n | 4 |
| Female, n | 6 |
| Treatment | |
| Preoperative RT, n | 10 |
| Radical surgery, n | 9 |
| Palliative surgery, n | 1 |
| Histology, n | |
| Liposarcoma | 6 |
| Spindle cell sarcoma | 2 |
| Leiomyosarcoma | 1 |
| Pleomorphic sarcoma | 1 |
| Tumor volume, mean (SD) | 2433 cm3 (3471 cm3) |
| PTV, mean (SD) | 3311 cm3 (3287 cm3) |
PTV, planning target volume; RT, radiotherapy; SD, standard deviation.
Dosimetric comparisons of target coverage and OARs between VMAT and swIMRT
| VMAT | swIMRT |
| |
|---|---|---|---|
| Number of arcs/beam angles, median (range) | 2.5 (2–4) | 5 (4–6) | <0.001 |
| PTV coverage (D95), mean (range) | 94.2% (88.8–97.7) | 92.5% (80.0–100.0) | 0.5 |
| CI, mean (range) | 0.88 (0.83–0.93) | 0.85 (0.80–0.91) | <0.001 |
| Uninvolved contralateral kidney mean dose (Gy), (range) | 7.0 (2.2–10.1) | 7.3 (2.3–12.8) | 0.8 |
| Liver mean dose (Gy), mean (range) | 14.9 (2.7–23.1) | 15.0 (2.8–22.4) | 0.6 |
| Spinal cord max dose (Gy), mean (range) | 26.9 (12.0–39.7) | 29.6 (16.0–45.1) | 0.1 |
| Bowel space (D195 cm3) (Gy) (range) | 38.7 (30.2–46.0) | 40.5 (33.5–47.4) | 0.1 |
| Unspecified tissue mean dose (Gy), mean (range) | 15.3 (11.3–21.7) | 15.9 (12.3–22.0) | 0.04 |
| DEVs (Gy), mean (range) | |||
| 1 cm from PTV | 39.9 (36.7–41.8) | 40.9 (39.0–42.3) | <0.001 |
| 2 cm from PTV | 33.2 (30.4–36.8) | 34.6 (31.7–36.9) | <0.001 |
| 5 cm from PTV | 21.7 (18.4–26.3) | 22.4 (18.8–26.1) | 0.009 |
| Monitor units, mean (range) | 490 (367–725) | 1042 (610–1570) | <0.001 |
| Treatment delivery time (min), mean (SD) | 1.75 (0.66) | 7.24 (1.18) | <0.001 |
CI, conformity index; D195 cm3, dose to 195 cm3 of bowel space; DEV, dose evaluation volume; Gy, SI unit of dose; OAR, organs at risk; PTV, planning target volume; SD, standard deviation; swIMRT, sliding window intensity‐modulated radiotherapy; VMAT, volumetric‐modulated arc therapy.