Corneal Deformation Parameters Provided by the Corvis-ST Pachy-Tonometer in Healthy Subjects and Glaucoma Patients.

Maria L Salvetat1, Marco Zeppieri, Claudia Tosoni, Mirella Felletti, Leonardo Grasso, Paolo Brusini.   

Abstract

PURPOSE: To evaluate precision and accuracy of Corvis-ST, a new noncontact tonometer equipped with a high-speed Scheimpflug technology, which measures intraocular pressure (IOP), central corneal thickness (CCT), and corneal deformation parameters (CDPs). Relationships among IOP, CCT, and CDPs were also assessed.
MATERIALS AND METHODS: This prospective, randomized study included 1 eye of 164 subjects (79 controls and 85 glaucoma patients), which underwent IOP measurements taken 3 times with Goldmann applanation tonometry (GAT) and Corvis-ST in random order. Precision was evaluated using intraclass correlation coefficients. Intermethod agreement was assessed using Bland-Altman method. Relationships amongst IOP, CCT and CDPs were evaluated using linear regression analysis.
RESULTS: Corvis-ST intraclass correlation coefficients ranged between 0.95 and 0.99 for IOP and CCT; between 0.17 and 0.97 for CDPs. Mean (GAT-Corvis-ST) IOP was 1.4±2.7 mm Hg, which appeared related to IOP and CDPs (P<0.05). CDPs significantly differed between glaucoma patients and controls (P<0.05). GAT and Corvis-ST IOP was related to CCT (P<0.05) and CDPs (P<0.001).
CONCLUSIONS: Corvis-ST precision was excellent for IOP and CCT; moderate for CDPs. Corvis-ST underestimated GAT IOP, especially at higher IOP and at lower corneal deformability levels. GAT and Corvis-ST IOP increased in thicker and less deformable corneas. Glaucoma patients showed significantly less deformable corneas than controls.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25318572     DOI: 10.1097/IJG.0000000000000133

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  25 in total

Review 1.  [Dynamic Scheimpflug Analyzer (Corvis ST) for measurement of corneal biomechanical parameters : A praxis-related overview].

Authors:  R Herber; N Terai; K R Pillunat; F Raiskup; L E Pillunat; E Spörl
Journal:  Ophthalmologe       Date:  2018-08       Impact factor: 1.059

Review 2.  Biomechanical Diagnostics of the Cornea.

Authors:  Vinicius S De Stefano; William J Dupps
Journal:  Int Ophthalmol Clin       Date:  2017

3.  Evaluation of Corvis ST tonometer with the updated software in glaucoma practice.

Authors:  Ioannis Halkiadakis; Vasilios Tzimis; Alexandros Gryparis; Ioannis Markopoulos; Vasiliki Konstadinidou; Elias Zintzaras; Michalis Tzakos
Journal:  Int J Ophthalmol       Date:  2022-03-18       Impact factor: 1.779

4.  Measurement repeatability of the dynamic Scheimpflug analyzer.

Authors:  Atsuya Miki; Naoyuki Maeda; Tomoko Asai; Yasushi Ikuno; Kohji Nishida
Journal:  Jpn J Ophthalmol       Date:  2017-10-05       Impact factor: 2.447

5.  The Relationship between Corvis ST Tonometry Measured Corneal Parameters and Intraocular Pressure, Corneal Thickness and Corneal Curvature.

Authors:  Ryo Asaoka; Shunsuke Nakakura; Hitoshi Tabuchi; Hiroshi Murata; Yoshitaka Nakao; Noriko Ihara; Ulfah Rimayanti; Makoto Aihara; Yoshiaki Kiuchi
Journal:  PLoS One       Date:  2015-10-20       Impact factor: 3.240

6.  Evaluation of Central Corneal Thickness Using Corneal Dynamic Scheimpflug Analyzer Corvis ST and Comparison with Pentacam Rotating Scheimpflug System and Ultrasound Pachymetry in Normal Eyes.

Authors:  Ayong Yu; Weiqi Zhao; Giacomo Savini; Zixu Huang; Fangjun Bao; Weicong Lu; Qinmei Wang; Jinhai Huang
Journal:  J Ophthalmol       Date:  2015-12-01       Impact factor: 1.909

7.  Automatic method of analysis and measurement of additional parameters of corneal deformation in the Corvis tonometer.

Authors:  Robert Koprowski
Journal:  Biomed Eng Online       Date:  2014-11-19       Impact factor: 2.819

Review 8.  Applications of Scheimpflug Imaging in Glaucoma Management: Current and Potential Applications.

Authors:  Alexander T Nguyen; Tiffany Liu; Ji Liu
Journal:  J Ophthalmol       Date:  2016-12-04       Impact factor: 1.909

9.  Changes in Corneal Biomechanical Properties after Long-Term Topical Prostaglandin Therapy.

Authors:  Na Wu; Yuhong Chen; Xiaobo Yu; Mengwei Li; Wen Wen; Xinghuai Sun
Journal:  PLoS One       Date:  2016-05-17       Impact factor: 3.240

10.  Comparison of Two Cap Thickness in Small Incision Lenticule Extraction: 100μm versus 160μm.

Authors:  Miao He; Wei Wang; Hui Ding; Xingwu Zhong
Journal:  PLoS One       Date:  2016-09-21       Impact factor: 3.240