Literature DB >> 25304715

Pediatric CT quality management and improvement program.

David B Larson1, Lior Z Molvin, Jia Wang, Frandics P Chan, Beverley Newman, Dominik Fleischmann.   

Abstract

Modern CT is a powerful yet increasingly complex technology that continues to rapidly evolve; optimal clinical implementation as well as appropriate quality management and improvement in CT are challenging but attainable. This article outlines the organizational structure on which a CT quality management and improvement program can be built, followed by a discussion of common as well as pediatric-specific challenges. Organizational elements of a CT quality management and improvement program include the formulation of clear objectives; definition of the roles and responsibilities of key personnel; implementation of a technologist training, coaching and feedback program; and use of an efficient and accurate monitoring system. Key personnel and roles include a radiologist as the CT director, a qualified CT medical physicist, as well as technologists with specific responsibilities and adequate time dedicated to operation management, CT protocol management and CT technologist education. Common challenges in managing a clinical CT operation are related to the complexity of newly introduced technology, of training and communication and of performance monitoring. Challenges specific to pediatric patients include the importance of including patient size in protocol and dose considerations, a lower tolerance for error in these patients, and a smaller sample size from which to learn and improve.

Entities:  

Mesh:

Year:  2014        PMID: 25304715     DOI: 10.1007/s00247-014-3039-4

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  17 in total

Review 1.  Multi-detector row CT systems and image-reconstruction techniques.

Authors:  Thomas G Flohr; Stefan Schaller; Karl Stierstorfer; Herbert Bruder; Bernd M Ohnesorge; U Joseph Schoepf
Journal:  Radiology       Date:  2005-04-15       Impact factor: 11.105

Review 2.  Principles of CT: radiation dose and image quality.

Authors:  Lee W Goldman
Journal:  J Nucl Med Technol       Date:  2007-11-15

3.  CT angiography for pulmonary embolism detection: the effect of breathing on pulmonary artery enhancement using a 64-row detector system.

Authors:  Julius Renne; Christian von Falck; Kristina Imeen Ringe; Hans-Jürgen Raatschen; Frank Wacker; Hoen-Oh Shin
Journal:  Acta Radiol       Date:  2013-10-08       Impact factor: 1.990

4.  Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part II. Implementation on abdomen and thorax phantoms using cross sectional CT images and scanned projection radiograph images.

Authors:  Jia Wang; Jodie A Christner; Xinhui Duan; Shuai Leng; Lifeng Yu; Cynthia H McCollough
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

5.  Patient size measured on CT images as a function of age at a tertiary care children's hospital.

Authors:  Patricia L Kleinman; Keith J Strauss; David Zurakowski; Kevin S Buckley; George A Taylor
Journal:  AJR Am J Roentgenol       Date:  2010-06       Impact factor: 3.959

6.  Comparison of different body size parameters for individual dose adaptation in body CT of adults.

Authors:  Jan Menke
Journal:  Radiology       Date:  2005-08       Impact factor: 11.105

Review 7.  Strategies for CT radiation dose optimization.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Leena M Hamberg; Michael A Blake; Jo-Anne Shepard; Sanjay Saini
Journal:  Radiology       Date:  2004-01-22       Impact factor: 11.105

8.  Effects of protocol and obesity on dose conversion factors in adult body CT.

Authors:  Xiang Li; Ehsan Samei; Cameron H Williams; W Paul Segars; Daniel J Tward; Michael I Miller; J Tilak Ratnanather; Erik K Paulson; Donald P Frush
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

9.  System for verifiable CT radiation dose optimization based on image quality. part II. process control system.

Authors:  David B Larson; Remo J Malarik; Seth M Hall; Daniel J Podberesky
Journal:  Radiology       Date:  2013-06-19       Impact factor: 11.105

10.  AAPM medical physics practice guideline 1.a: CT protocol management and review practice guideline.

Authors:  Dianna D Cody; Tyler S Fisher; Dustin A Gress; Rick Robert Layman; Michael F McNitt-Gray; Robert J Pizzutiello; Lynne A Fairobent
Journal:  J Appl Clin Med Phys       Date:  2013-09-06       Impact factor: 2.102

View more
  3 in total

1.  Benchmarking pediatric cranial CT protocols using a dose tracking software system: a multicenter study.

Authors:  Timo De Bondt; Tom Mulkens; Federica Zanca; Lotte Pyfferoen; Jan W Casselman; Paul M Parizel
Journal:  Eur Radiol       Date:  2016-06-03       Impact factor: 5.315

2.  A Toolkit for Pediatric CT Dose Reduction in Community Hospitals.

Authors:  Diane Armao; Terry Hartman; Christopher M Shea; Cassandra Sams; Marija Ivanovic; Lynn Ansley Fordham; J Keith Smith
Journal:  J Am Coll Radiol       Date:  2016-06-09       Impact factor: 5.532

3.  Computed tomography-guided biopsies in children: accuracy, efficiency and dose usage.

Authors:  Tatjana Gruber-Rouh; Axel Thalhammer; Thomas Klingebiel; Nour-Eldin A Nour-Eldin; Thomas J Vogl; Katrin Eichler; Nagy Naguib; Martin Beeres
Journal:  Ital J Pediatr       Date:  2017-01-06       Impact factor: 2.638

  3 in total