Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.

Laryssa A Korduba, Aaron Essner, Robert Pivec, Perry Lancin, Michael A Mont1, Aiguo Wang, Ronald E Delanois.   

Abstract

The effect of acetabular component positioning on the wear rates of metal-on-polyethylene articulations has not been extensively studied. Placement of acetabular cups at abduction angles of more than 40° has been noted as a possible reason for early failure caused by increased wear. We conducted a study to evaluate the effects of different acetabular cup abduction angles on polyethylene wear rate, wear area, contact pressure, and contact area. Our in vitro study used a hip joint simulator and finite element analysis to assess the effects of cup orientation at 4 angles (0°, 40°, 50°, 70°) on wear and contact properties. Polyethylene bearings with 28-mm cobalt-chrome femoral heads were cycled in an environment mimicking in vivo joint fluid to determine the volumetric wear rate after 10 million cycles. Contact pressure and contact area for each cup abduction angle were assessed using finite element analysis. Results were correlated with cup abduction angles to determine if there were any differences among the 4 groups. The inverse relationship between volumetric wear rate and acetabular cup inclination angle demonstrated less wear with steeper cup angles. The largest abduction angle (70°) had the lowest contact area, largest contact pressure, and smallest head coverage. Conversely, the smallest abduction angle (0°) had the most wear and most head coverage. Polyethylene wear after total hip arthroplasty is a major cause of osteolysis and aseptic loosening, which may lead to premature implant failure. Several studies have found that high wear rates for cups oriented at steep angles contributed to their failure. Our data demonstrated that larger cup abduction angles were associated with lower, not higher, wear. However, this potentially "protective" effect is likely counteracted by other complications of steep cup angles, including impingement, instability, and edge loading. These factors may be more relevant in explaining why implants fail at a higher rate if cups are oriented at more than 40° of abduction.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25303445

Source DB:  PubMed          Journal:  Am J Orthop (Belle Mead NJ)        ISSN: 1078-4519


  9 in total

1.  Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?

Authors:  Adrian Bauze; Somen Agrawal; Alana Cuthbert; Richard de Steiger
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

2.  A retrospective study on the relationship between altered native acetabular angle and vertical implant malpositioning.

Authors:  Jorge Rojas; Maria Bautista; Guillermo Bonilla; Omar Amado; Elina Huerfano; Daniel Monsalvo; Adolfo Llinás; José Navas
Journal:  Int Orthop       Date:  2017-08-07       Impact factor: 3.075

3.  Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement.

Authors:  Marzieh M Ardestani; Pedro P Amenábar Edwards; Markus A Wimmer
Journal:  Clin Orthop Relat Res       Date:  2017-03-02       Impact factor: 4.176

4.  Clinical Impact of Pelvic Malrotation on Radiograph-Based Preoperative Planning for Total Hip Arthroplasty: A Proof-of-Concept and Prudent Prediction of Acceptable Rotation.

Authors:  Ernest Lourens; Andrew P Kurmis; Wan Yin Lim
Journal:  Indian J Orthop       Date:  2022-03-30       Impact factor: 1.033

5.  Personalized Cup Positioning Guides Improved Cup Positioning and Hip Ranges of Motion in Robotic Assisted Total Hip Arthroplasty.

Authors:  Ruoyu Wang; Xiaojing Zheng; Tianze Xu; Song Gong; Shaokai Liu; Lizhi Han; Shuhua Yang; Weihua Xu
Journal:  Front Bioeng Biotechnol       Date:  2020-08-21

6.  Acetabular cup version modelling and its clinical applying on plain radiograms.

Authors:  Anton Denisov; Stanislav Bilyk; Anton Kovalenko
Journal:  World J Orthop       Date:  2017-12-18

7.  Outcomes of Total Hip Arthroplasty in Patients With Acetabular Protrusio.

Authors:  Danielle Greig; Peter P Hsiue; Clark J Chen; Rishi Trikha; Amir Khoshbin; Alexandra I Stavrakis
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2020-07

8.  Surgical cup placement affects the heating up of total joint hip replacements.

Authors:  Philipp Damm; Alwina Bender; Vivian Waldheim; Tobias Winkler; Georg N Duda
Journal:  Sci Rep       Date:  2021-08-04       Impact factor: 4.379

9.  Radiographic results on acetabular cup placement with the SuperPath technique: a retrospective study of 756 cases.

Authors:  Agostino Di Maro; Santo Creaco; Mattia Albini; Mahfuz Latiff; Marco Merlo
Journal:  BMC Musculoskelet Disord       Date:  2022-01-31       Impact factor: 2.362

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.