Literature DB >> 28782077

A retrospective study on the relationship between altered native acetabular angle and vertical implant malpositioning.

Jorge Rojas1, Maria Bautista2, Guillermo Bonilla3, Omar Amado1, Elina Huerfano1, Daniel Monsalvo1, Adolfo Llinás4, José Navas1.   

Abstract

PURPOSE: Acetabular cup positioning in extreme angles of vertical position affects both stability and long-term survivorship of total hip arthroplasty. The purpose of this study is to determine whether native Sharp's angle is associated with an increased abduction angle of the acetabular component.
METHODS: Consecutive patients who underwent primary total hip replacement between February 2012 and August 2015 were included. Vertical positioning of acetabular implant in the antero-posterior post-operative radiographs were measured. The proportion of implants positioned outside the safe zone (40° ± 10°) was calculated and through a multivariate analysis, Sharp's angle and other factors possibly associated with cup malpositioning were evaluated.
RESULTS: Five hundred twenty-eight hip arthroplasties were analyzed. Prevalence of cup malpositioning was 7.6% and 25 patients had an altered native acetabular angle. An altered pre-operative Sharp's angle was associated with a higher risk of vertical malpositioning of the acetabular component (OR 2.51 IC 95%: 1.17-5.39) (p = 0.02). Body mass index, surgeon's volume, size of the implant, gender, pre-operative diagnose and age, were not associated with the position of the cup.
CONCLUSIONS: The alteration of the Sharp's angle as an indicator of hip dysplasia in native hips increases the odds of acetabular cup malpositioning. Other factors explored did not correlate with the position of the acetabular prosthesis. Systematic assessment of Sharp's angle should be included in the pre-operative planning of primary hip arthroplasty.

Entities:  

Keywords:  Acetabular cup positioning; Acetabulum; Artrhoplasty, replacement, hip; Hip prosthesis implantation

Mesh:

Year:  2017        PMID: 28782077     DOI: 10.1007/s00264-017-3584-1

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  32 in total

1.  Use of an ultrasound-based navigation system for an accurate acetabular positioning in total hip arthroplasty: a prospective, randomized, controlled study.

Authors:  Georgi I Wassilew; Carsten Perka; Viktor Janz; Christian König; Patrick Asbach; Olaf Hasart
Journal:  J Arthroplasty       Date:  2011-10-13       Impact factor: 4.757

2.  Comparison of robotic-assisted and conventional acetabular cup placement in THA: a matched-pair controlled study.

Authors:  Benjamin G Domb; Youssef F El Bitar; Adam Y Sadik; Christine E Stake; Itamar B Botser
Journal:  Clin Orthop Relat Res       Date:  2013-08-29       Impact factor: 4.176

3.  Learning curve of acetabular cup positioning in total hip arthroplasty using a cumulative summation test for learning curve (LC-CUSUM).

Authors:  Young-Kyun Lee; David J Biau; Byung-Ho Yoon; Tae-Young Kim; Yong-Chan Ha; Kyung-Hoi Koo
Journal:  J Arthroplasty       Date:  2013-08-30       Impact factor: 4.757

4.  Research synthesis of recommended acetabular cup orientations for total hip arthroplasty.

Authors:  Claire L Harrison; Avril I Thomson; Steven Cutts; Philip J Rowe; Philip E Riches
Journal:  J Arthroplasty       Date:  2013-08-17       Impact factor: 4.757

5.  Predictive value of robotic-assisted total hip arthroplasty.

Authors:  Youssef F El Bitar; Timothy J Jackson; Dror Lindner; Itamar B Botser; Christine E Stake; Benjamin G Domb
Journal:  Orthopedics       Date:  2015-01       Impact factor: 1.390

6.  Early aseptic loosening of cementless monoblock acetabular components.

Authors:  Simo S A Miettinen; Tatu J Mäkinen; Inari Laaksonen; Keijo Mäkelä; Heini Huhtala; Jukka Kettunen; Ville Remes
Journal:  Int Orthop       Date:  2016-08-10       Impact factor: 3.075

7.  The effect of orientation of the acetabular component on outcome following total hip arthroplasty with small diameter hard-on-soft bearings.

Authors:  G Grammatopoulos; G E R Thomas; H Pandit; D J Beard; H S Gill; D W Murray
Journal:  Bone Joint J       Date:  2015-02       Impact factor: 5.082

8.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

9.  Acetabular Anteversion Changes Due to Spinal Deformity Correction: Bridging the Gap Between Hip and Spine Surgeons.

Authors:  Aaron J Buckland; Jonathan Vigdorchik; Frank J Schwab; Thomas J Errico; Renaud Lafage; Christopher Ames; Shay Bess; Justin Smith; Gregory M Mundis; Virginie Lafage
Journal:  J Bone Joint Surg Am       Date:  2015-12-02       Impact factor: 5.284

10.  Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.

Authors:  Laryssa A Korduba; Aaron Essner; Robert Pivec; Perry Lancin; Michael A Mont; Aiguo Wang; Ronald E Delanois
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2014-10
View more
  6 in total

1.  Cup alignment in total hip arthroplasty using the muscle-sparing modified Watson-Jones approach-comparison between lateral and supine positions.

Authors:  Yuichi Kishimura; Yukihide Minoda; Shigekazu Mizokawa; Ryo Sugama; Yoichi Ohta; Hiroaki Nakamura
Journal:  Int Orthop       Date:  2019-03-06       Impact factor: 3.075

2.  Is the position of dual-mobility cup in THA for femoral neck fractures optimal? A retrospective study.

Authors:  Pierre-Alban Bouche; Simon Corsia; Baptiste Boukebous; Pierre Boutroux; Redoine Zahi; Pascal Guillon
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-10-08

3.  Clinical Impact of Pelvic Malrotation on Radiograph-Based Preoperative Planning for Total Hip Arthroplasty: A Proof-of-Concept and Prudent Prediction of Acceptable Rotation.

Authors:  Ernest Lourens; Andrew P Kurmis; Wan Yin Lim
Journal:  Indian J Orthop       Date:  2022-03-30       Impact factor: 1.033

4.  Lewinnek Safe Zone References are Frequently Misquoted.

Authors:  Aonnicha Burapachaisri; Ameer Elbuluk; Edem Abotsi; Jim Pierrepont; Seth A Jerabek; Aaron J Buckland; Jonathan M Vigdorchik
Journal:  Arthroplast Today       Date:  2020-11-26

5.  Acetabular positioning is more consistent with the use of a novel miniature computer-assisted device.

Authors:  Ivan Jacob; Jessica Benson; Kate Shanaghan; Alejandro Gonzalez Della Valle
Journal:  Int Orthop       Date:  2020-01-22       Impact factor: 3.075

6.  Total hip arthroplasty with a monoblock conical stem and subtrochanteric transverse shortening osteotomy in Crowe type IV dysplastic hips.

Authors:  Guido Grappiolo; Francesco La Camera; Antonello Della Rocca; Giuseppe Mazziotta; Giuseppe Santoro; Mattia Loppini
Journal:  Int Orthop       Date:  2018-09-05       Impact factor: 3.075

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.