A novel Region of Interest (ROI) imaging technique for biplane imaging in interventional suites: high-resolution small field-of-view imaging in the frontal plane and dose-reduced, large field-of-view standard-resolution imaging in the lateral plane.

S N Swetadri Vasan1, C Ionita2, D R Bednarek2, S Rudin1.   

Abstract

Endovascular-Image-Guided-Interventional (EIGI) treatment of neuro-vascular conditions such as aneurysms, stenosed arteries, and vessel thrombosis make use of treatment devices such as stents, coils, and balloons which have very small feature sizes, 10's of microns to a few 100's of microns, and hence demand a high resolution imaging system. The current state-of-the-art flat panel detector (FPD) has about a 200-um pixel size with the Nyquist of 2.5 lp/mm. For higher-resolution imaging a charge-coupled device (CCD) based Micro-Angio -Fluoroscope (MAF-CCD) with a pixel size of 35um (Nyquist of 11 lp/mm) was developed and previously reported. Although the detector addresses the high resolution needs, the Field-Of-View (FOV) is limited to 3.5 cm × 3.5 cm, which is much smaller than current FPDs. During the use of the MAF-CCD for delicate parts of the intervention, it may be desirable to have real-time monitoring outside the MAF FOV with a low dose, and lower, but acceptable, quality image. To address this need, a novel imaging technique for biplane imaging systems has been developed, using an MAF-CCD in the frontal plane and a dose-reduced standard large FOV imager in the lateral plane. The dose reduction is achieved by using a combination of ROI fluoroscopy and spatially different temporal filtering, a technique that has been previously presented. In order to evaluate this technique, a simulation using images acquired during an actual EIGI treatment on a patient, followed by an actual implementation on phantoms is presented.

Entities:  

Year:  2014        PMID: 25302001      PMCID: PMC4188443          DOI: 10.1117/12.2043460

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  7 in total

1.  Region of interest fluoroscopy.

Authors:  S Rudin; D R Bednarek
Journal:  Med Phys       Date:  1992 Sep-Oct       Impact factor: 4.071

2.  New head equivalent phantom for task and image performance evaluation representative for neurovascular procedures occurring in the Circle of Willis.

Authors:  Ciprian N Ionita; Brendan Loughran; Amit Jain; S N Swetadri Vasan; Daniel R Bednarek; Elad Levy; Adnan H Siddiqui; Kenneth V Snyder; L N Hopkins; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-02-23

3.  Dose Reduction Technique Using a Combination of a Region of Interest (ROI) Material X-Ray Attenuator and Spatially Different Temporal Filtering for Fluoroscopic Interventions.

Authors:  S N Swetadri Vasan; A Panse; A Jain; P Sharma; Ciprian N Ionita; A H Titus; A N Cartwright; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-02-23

4.  A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager.

Authors:  Amit Jain; D R Bednarek; Ciprian Ionita; S Rudin
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

5.  Spatially different, real-time temporal filtering and dose reduction for dynamic image guidance during neurovascular interventions.

Authors:  S N Swetadri Vasan; P Sharma; C N Ionita; A H Titus; A N Cartwright; D R Bednarek; S Rudin
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

6.  Dose Reduction in Fluoroscopic Interventions Using a Combination of a Region of Interest (ROI) X-Ray Attenuator and Spatially-Different, Temporally-Variable Temporal Filtering.

Authors:  S N Swetadri Vasan; Liza Pope; Ciprian N Ionita; A H Titus; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-06

7.  Endovascular image-guided interventions (EIGIs).

Authors:  Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

  7 in total
  3 in total

1.  A simulation platform using 3D printed neurovascular phantoms for clinical utility evaluation of new imaging technologies.

Authors:  S V Setlur Nagesh; J Hinaman; K Sommer; Z Xiong; C N Ionita; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-12

2.  A Patient Dose-Reduction Technique for Neuroendovascular Image-Guided Interventions: Image-Quality Comparison Study.

Authors:  A Sonig; S V Setlur Nagesh; V S Fennell; S Gandhi; L Rangel-Castilla; C N Ionita; K V Snyder; L N Hopkins; D R Bednarek; S Rudin; A H Siddiqui; E I Levy
Journal:  AJNR Am J Neuroradiol       Date:  2018-02-15       Impact factor: 3.825

3.  Society of Vascular and Interventional Neurology (SVIN) Stroke Interventional Laboratory Consensus (SILC) Criteria: A 7M Management Approach to Developing a Stroke Interventional Laboratory in the Era of Stroke Thrombectomy for Large Vessel Occlusions.

Authors:  Tanzila Shams; Osama Zaidat; Dileep Yavagal; Andrew Xavier; Tudor Jovin; Vallabh Janardhan
Journal:  Interv Neurol       Date:  2016-02-26