Literature DB >> 16602578

Improving EMG-based muscle force estimation by using a high-density EMG grid and principal component analysis.

Didier Staudenmann1, Idsart Kingma, Andreas Daffertshofer, Dick F Stegeman, Jaap H van Dieën.   

Abstract

The accuracy of predictions of muscle force based on electromyography (EMG) is an important issue in biomechanics and kinesiology. Since human skeletal muscles show a high diversity and heterogeneity in their fiber architecture, it is difficult to properly align electrodes to the muscle fiber direction. Against this background, we analyzed the effect of different bipolar configuration directions on EMG-based force estimation. In addition, we investigated whether principal component analysis (PCA) can improve this estimation. High-density surface-EMG from the triceps brachii muscle and the extension force of the elbow were measured in 11 subjects. The root mean square difference (RMSD) between predicted and measured force was determined. We found the best bipolar configuration direction to cause a 13% lower RMSD relative to the worst direction. Optimal results were obtained with electrodes aligned with the expected main muscle fiber direction. We found that PCA reduced RMSD by about 40% compared to conventional bipolar electrodes and by about 12% compared to optimally aligned multiple bipolar electrodes. Thus, PCA contributes to the accuracy of EMG-based estimation of muscle force when using a high-density EMG grid.

Entities:  

Mesh:

Year:  2006        PMID: 16602578     DOI: 10.1109/TBME.2006.870246

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  22 in total

1.  Spatial variability in cortex-muscle coherence investigated with magnetoencephalography and high-density surface electromyography.

Authors:  Harri Piitulainen; Alberto Botter; Mathieu Bourguignon; Veikko Jousmäki; Riitta Hari
Journal:  J Neurophysiol       Date:  2015-09-09       Impact factor: 2.714

2.  A new layered sensor for simultaneous measurement of EMG, MMG and oxygen consumption at the same position.

Authors:  Akira Kimoto; Yuji Yamada
Journal:  Med Biol Eng Comput       Date:  2014-10-10       Impact factor: 2.602

Review 3.  The extraction of neural strategies from the surface EMG: an update.

Authors:  Dario Farina; Roberto Merletti; Roger M Enoka
Journal:  J Appl Physiol (1985)       Date:  2014-10-02

4.  Functional connectivity in the neuromuscular system underlying bimanual coordination.

Authors:  Ingmar E J de Vries; Andreas Daffertshofer; Dick F Stegeman; Tjeerd W Boonstra
Journal:  J Neurophysiol       Date:  2016-09-14       Impact factor: 2.714

5.  Applying dimension reduction to EEG data by Principal Component Analysis reduces the quality of its subsequent Independent Component decomposition.

Authors:  Fiorenzo Artoni; Arnaud Delorme; Scott Makeig
Journal:  Neuroimage       Date:  2018-03-09       Impact factor: 6.556

6.  Two degrees of freedom quasi-static EMG-force at the wrist using a minimum number of electrodes.

Authors:  Edward A Clancy; Carlos Martinez-Luna; Marek Wartenberg; Chenyun Dai; Todd R Farrell
Journal:  J Electromyogr Kinesiol       Date:  2017-03-29       Impact factor: 2.368

7.  Semi-automated Detection of Polysomnographic REM Sleep without Atonia (RSWA) in REM Sleep Behavioral Disorder.

Authors:  Iva Milerska; Vaclav Kremen; Vaclav Gerla; Erik K St Louis; Lenka Lhotska
Journal:  Biomed Signal Process Control       Date:  2019-03-07       Impact factor: 3.880

8.  Robust and accurate decoding of motoneuron behaviour and prediction of the resulting force output.

Authors:  Christopher K Thompson; Francesco Negro; Michael D Johnson; Matthew R Holmes; Laura Miller McPherson; Randall K Powers; Dario Farina; Charles J Heckman
Journal:  J Physiol       Date:  2018-06-09       Impact factor: 5.182

9.  EMG-force relation in the first dorsal interosseous muscle of patients with amyotrophic lateral sclerosis.

Authors:  Faezeh Jahanmiri-Nezhad; Xiaogang Hu; Nina L Suresh; William Z Rymer; Ping Zhou
Journal:  NeuroRehabilitation       Date:  2014-01-01       Impact factor: 2.138

10.  A novel system of electrodes transparent to ultrasound for simultaneous detection of myoelectric activity and B-mode ultrasound images of skeletal muscles.

Authors:  A Botter; T M M Vieira; I D Loram; R Merletti; E F Hodson-Tole
Journal:  J Appl Physiol (1985)       Date:  2013-08-01
View more