Literature DB >> 25265890

The utility of intra-operative three-dimensional transoesophageal echocardiography for dynamic measurement of stroke volume.

K Suehiro1, K Tanaka, T Yamada, T Matsuura, T Funao, T Mori, K Nishikawa.   

Abstract

Measurement of left ventricular stroke volume and cardiac output is very important for managing haemodynamically unstable or critically ill patients. The aims of this study were to compare stroke volume measured by three-dimensional transoesophageal echocardiography with stroke volume measured using a pulmonary artery catheter, and to examine the ability of three-dimensional transoesophageal echocardiography to track stroke volume changes induced by haemodynamic interventions. This study included 40 cardiac surgery patients. Haemodynamic variables were measured before and 2 min after haemodynamic interventions, which consisted of phenylephrine 100 μg or ephedrine 5 mg. We used Bland-Altman analysis to assess the agreement between the stroke volume measured by three-dimensional transoesophageal echocardiography and by the pulmonary artery catheter. Polar-plot and 4-quadrant plot analyses were used to assess the trending ability of three-dimensional transoesophageal echocardiography compared with the pulmonary artery catheter. Bias and percentage error were -1.2 ml and 20%, respectively. The concordance rate in the 4-quadrant analysis after phenylephrine and ephedrine administration was 75% and 84%, respectively. In the polar-plot analysis, the angular concordance rate was 66% and 73% after phenylephrine and ephedrine administration, respectively. Three-dimensional transoesophageal echocardiography was clinically acceptable for measuring stroke volume; however, it was not sufficiently reliable for tracking stroke volume changes after haemodynamic interventions.
© 2014 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25265890     DOI: 10.1111/anae.12857

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  4 in total

1.  Severe loss of right ventricular longitudinal contraction occurs after cardiopulmonary bypass in patients with preserved right ventricular output.

Authors:  Lars Grønlykke; André Korshin; Frederik Holmgaard; Sven Morten Kjøller; Finn Gustafsson; Jens Chr Nilsson; Hanne Berg Ravn
Journal:  Int J Cardiovasc Imaging       Date:  2019-05-02       Impact factor: 2.357

2.  Impact of non-invasive continuous blood pressure monitoring on maternal hypotension during cesarean delivery: a randomized-controlled study.

Authors:  Takashi Juri; Koichi Suehiro; Aya Kimura; Akira Mukai; Katsuaki Tanaka; Tokuhiro Yamada; Takashi Mori; Kiyonobu Nishikawa
Journal:  J Anesth       Date:  2018-09-28       Impact factor: 2.078

3.  Impact of continuous non-invasive blood pressure monitoring on hemodynamic fluctuation during general anesthesia: a randomized controlled study.

Authors:  Takashi Juri; Koichi Suehiro; Aya Kimura; Akira Mukai; Katsuaki Tanaka; Tokuhiro Yamada; Takashi Mori; Kiyonobu Nishikawa
Journal:  J Clin Monit Comput       Date:  2018-03-06       Impact factor: 2.502

4.  Passive Self Resonant Skin Patch Sensor to Monitor Cardiac Intraventricular Stroke Volume Using Electromagnetic Properties of Blood.

Authors:  Fayez Alruwaili; Kim Cluff; Jacob Griffith; Hussam Farhoud
Journal:  IEEE J Transl Eng Health Med       Date:  2018-09-26       Impact factor: 3.316

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.